Olympia RM 10 mini Bruksanvisning

Olympia Rökdetektor RM 10 mini

Läs gratis den bruksanvisning för Olympia RM 10 mini (1 sidor) i kategorin Rökdetektor. Guiden har ansetts hjälpsam av 19 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 7 recensioner. Har du en fråga om Olympia RM 10 mini eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/1
11-1612-169-1610-16
7-168-165-166-16
Install at a distance of at least 50 cm from uorescent
light sources.
50 cm
Fig.8
smoke alarm
Fig.7
the install distance should be 61cm at least from the
To mount the smoke alarm, proceed as follows:
Use the screws to x the base plate in the place
chosen. Pay attention to the gure above(Fig.4-Fig.8).
Gently tighten the alarm onto the base plate.
Mount the alarm in the centre of the ceiling of the room.
Do not mount the alarm in a place which is dicult to
reach.
The smoke alarm may not be painted.
Fig.9
Twist to tighten
Twist to loose
SCREWS
SCREWS
Bracket
10-YEAR BATTERY
SMOKE ALARM
Read the instruction manual before usage.
1. General
This is a smoke alarm device using the photoelectric
principle. Its designed for detecting smoke in the air,
while not for sensing heat, gas or ame. If the smoke
alarm is properly mounted and maintained, it will be
activated at the very start. The smoke alarm is
designed to detect smoke, it can not prevent a re.
Please read the instruction manual carefully before you
use this smoke alarm.
The device hereinafter stands for smoke alarm
device.
2.Device & Spare parts
1
2
3
1-Main unit
2-user manual
3-Screws and dowels ( 2
sets)
Fig.1
2-16
3.General gure
4.Power on
Fig.2
LED indicator
Test/Hush button
Smoke inlet
Back cover
Fig.3
3-16
Unscrew the bottom cover, remove the small magnet, the
power is switched on(Fig3).
CAUTION: built-in Lithium battery of product can not be
replaced. Standby time is 10 years at normal use
condition.
5.Device specications
DimensionΦ45x42 mm
Weight50g
Operate Temperature0 -50
Working voltage3V
Standby current≤7uA
Humidity10%-90%
Service environment: house supply
Designed life10 year
Note: If the product is energized, put the small magnet
back in place to switch into power o. (If there is no LED
lights ashing and successive Beep alarm signal given
when long press the Test/Hush button, it indicates the
device is power o.)
The device is energized and working if its with LED
indicator ashing and continuous Beep alarm sound by
pressing the Test/Hush button.
4-16
15-1613-1614-16
6.Mounting
The smoke alarm should be mounted in the following
places:
at least one in each room
one on each oor, if the oor is too long, there shall be
mounted two or more smoke alarms
in the hallway, in the staircase
in the living room
in each bedroom
in the storage room or spaces with electric
equipment
The alarm may not be mounted in
the following places:
a room in which the temperature can drop
below 0°C or rise above 50°C
in damp rooms
in front of doors or windows
near a ventilator or radiator.
Smoke alarm for minimal protection
Smoke alarm for extra protection
Fig.4
1. Bedroom
2. Bedroom
3. Staircase
4. Bedroom
5. Livingroom
6. Kitchen
7. Entrance
8. Hobby area
9.Guest bathroom
10. Bathroom
11. Storage
12. Garage
Fig.5
Do not install in the tip of a
sloping ceiling,as smoke-free air
can collect in these areas. If
the ceiling slopes over 30°
and has a total height of
up to 6 m, a distance of
30-50 cm from the tip
is to be observed. If the slope is up to 45° the
smoke alarm can be installed on the slope.
Fig.6
30°
30 - 50 cm
6 m
The Test/Hush button is long pressed till the device
gives audible alarm continuously beep and visible
alarm LED blinking when the test is going on. When
the Test/Hush button is released, the audible and
visible alarm stops, meanwhile the device goes to
hush mode. Repeat the above steps to exit Hush
mode.
7. Functionality
7.2 Standby mode
The device goes to standby mode once powered on,
with once LED blinking every 344 second
Fig.10
7.1 This device is capable of self-regulating to long
term drift of photoelectric chamber to ensure
long-time stability of device
7.3 Test
Fig.11
~
DI DI DI DI ~
7.4 Hush mode
1. In the standby mode, press the Test/Hush button,
the device enters hush mode.
2. In the state of alarm, press the Test/Hush button,
the device enters hush mode.
3. The whole process of the hush mode lasts for 9
minutes.
4. In the hush mode, hold the Test/Hush button until
Fig.12
acoustic alarm signal is emitted, the device exits the
hush mode and returns to standby mode.
Attention:
1. No matter mode of standby or alarm, press the
Test/Hush button, the device enters hush mode. LED
indicator light ashes once every 10 seconds. Hold the
Test/Hush button until acoustic alarm signal is
emitted, the device exits the hush mode.
2. If long press the Test/Hush button to make the
device emit alarm sound signal, then the device wont
enter into hush mode. The device will enter into hush
mode only if press the Test/Hush button shortly.
3. When the device is in standby mode or hush mode,
please pay close attention to the LED ashing time
interval, if LED ashing once every 10 seconds, its in
hush mode, while if LED ashing once every 344
seconds, its in standby mode.
4. On hush mode, the device gives normal alarm when
the smoke concentration in the ambience is more than
4 times of alarming value.
every 10 seconds
7.5 Low battery
7.6 Malfunction or end-of-life
When the device is on low-battery condition
(2.4v±0.1v), it sounds once beep every 43
seconds.
When the device malfunctions or is to be end
of life, it sounds continuously beep every 43
seconds.
Fig.13
Fig.14
DI DI DI
DI
Please replace device under conditions of
malfunction, end of life or low-battery warning.
IMPORTANT
When the device is alarming or on standby, pressing
the Test/Hush button once, it goes to hush mode;
pressing the Test/Hush button once again, it exits
hush mode.
Placing a smoke alarm is a part of your re protection,
just as re extinguishers, emergency ladders, ropes,
but also your choice in the use of building materials for
renovation. Always ensure that there is an evacuation
plan, discuss this with your children. Ensure that each
room can be left without opening the door, e.g. by the
window. If there is any question as to the cause of an
alarm, it should be assumed that the alarm is due to an
actual re and the dwelling evacuated immediately.
8. Precautions for use
Test weekly
Do not paint
Not use this device in dusty or smoky ambience.
Both designed device lifetime and battery standby
time (including test weekly) is 10 years. The battery
service time decreases if frequent alarm or long time
alarm.
This device is not a device for re rescue or re
prevention, but an alarm to warn escape or notify
reman when there is a re accident with smoke
arisen. Hence its necessary to take precautions
against re, allocating like extinguisher, emergency
ladders and re blanket.
The user with hearing disorder cant make aware of
audible alarm when this device is used, so we
recommend this kind of users wireless or wired
interconnected smoke alarm with ash light indication.
WE can never be made liable for loss and / or
damage of whatever nature, including incidental and /
or didn't use it according to the instruction and/ or
consequential loss, arising from the fact that the signal
from the smoke alarm did not sound during smoke or
re.
0086-CPR-550646
RM mini User Manual10
Guarantee
we are plshay have csenhis eipmt.eaed tt ouho tquen
In case oa defecplease return t vicether thef t, hede toge
with receip original cki material to point thet andpang the
of-sale.
10-YEAR BATTERY
SMOKE ALARM
Read the instruction manual before usage.
0086-CPR-550646
RM mini User Manual10

Betygsätt denna manual

4.6/5 (7 Recensioner)

Produktspecifikationer

Varumärke: Olympia
Kategori: Rökdetektor
Modell: RM 10 mini
Vikt: 50 g
Höjd: 42 mm
Diameter: 45 mm
Certifiering: CE, RoHS
Detektortyp: Fotoelektrisk reflektionsdetektor
Batteriteknik: Litium-Ion (Li-Ion)
Batterityp: Inbyggd
Testknapp: Ja
Batteriets livslängd: 10 År
Antal batterier: 1
Produktens färg: Vit
bruksanvisning: Ja
Enkel installation: Ja
Temperatur vid drift: 0 - 50 ° C
Intervall för relativ operativ luftfuktighet: 10 - 90 %
Anslutningsteknologi: Trådlös
Monteringssätt: Ytmonterad
Batterispänning: 3 V
Strömkälla: Batteri
Bästa användningsområden: Hem
Indikator för låg batterinivå: Ja
Ljudstyrka på alarm: 85 dB
Skruvar medföljer: Ja
Larmavstängning: Ja
Hopkopplingsbara: Nej
Lätt larm: Ja

Behöver du hjälp?

Om du behöver hjälp med Olympia RM 10 mini ställ en fråga nedan och andra användare kommer att svara dig