Läs gratis den bruksanvisning för Optex FLX-S-ST (13 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 20 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 10.5 recensioner. Har du en fråga om Optex FLX-S-ST eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/13

FlipX series
Flexible Range Indoor Detector
Flexible Range Indoor Detector
FlipX series
STANDARD MODELS
INSTALLATION INSTRUCTIONS
No.59-3043-0 2201-27
UL No.59-3043-0 2104-12
EN
1
- Manufacturer’ s statement
- Parts identification
- Specifications
- Dimensions
- Detection area
- Angle adjustment
with bracket CW-G2
- Compliance
Before installation
Others
<< Contents >>
Page
2
3
Installation
Wall mount
without bracket
Assemble and connect
Jumper pin settings
Wide/Narrow setting
1
Wall mount
with bracket
Ceiling mount
with bracket
Settings2
Disasseble
Checking3
3
4 5 6
7
8
11
12
13
13
8
12
10
Wide/Narrow area
Flip lens
PIR Microwave Mounting bracket
FLX-S-ST - -✓ ✓
FLX-S-ST-BKT*3 -✓ ✓ ✓
FLX-S-DT-X5*1 (10.525GHz) -✓ ✓ ✓
FLX-S-DT-X5-BKT*3 (10.525GHz)✓ ✓ ✓ ✓
FLX-S-DT-X8*2 (10.587GHz) -✓ ✓ ✓
FLX-S-DT-X9*3 (9.425GHz) -✓ ✓ ✓
*1 Not certified to INCERT
*2 Not certified to SBSC and UL
*3 Not certified to EN 50131-2-2 :2017 (FLX-S-ST-BKT)/EN 50131-2-4:2020 (FLX-S-DT-X5-BKT/X9),
INCERT, SBSC and UL

- Manufacturer’ s statement
NOTE
Failure to follow the instructions provided with this indication
and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication
and improper handling may cause injury and/or property damage.
Check mark indicates recommendation.
Nix sign indicates prohibition.
Special attention is required to the
section of this symbol.
Mounting height
2.0 to 3.0 m (6’7” to 9’8”)
2.4 m (8’) recommended
Symbol Meaning
Warning
Caution
Warning
Caution
< 1m
Wetting with water
2
Symbol Meaning
Before installation
Destroy
modify
<1m
[ FLX-S-DT only ]
Outdoor installation
Detection through glass
Face to face/Back interference
Follow to the Regulations
Partial/complete obscuration
of the detection area.

1-1. Disassemble
Open the cover Remove the main unit
Cover
Main unit
Base
Unlock the cover
- Parts identifications
Installation
1
180°
3
123
Sponge
Lens
Pull
Do not touch
MW and PIR
units.
CW-G2 *
Bracket for wall/ceiling mount
Models with “-BKT” in the model
name include CW-G2.
Option
*
Not certified to EN 50131-2-2:2017
/EN 50131-2-4:2020, INCERT and SBSC
NOTE
Joint screw x 3
Fixing screw x 2
Produktspecifikationer
Varumärke: | Optex |
Kategori: | Inte kategoriserad |
Modell: | FLX-S-ST |
Behöver du hjälp?
Om du behöver hjälp med Optex FLX-S-ST ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Optex Manualer
21 December 2024
6 December 2024
6 December 2024
6 December 2024
6 December 2024
6 December 2024
6 December 2024
2 Oktober 2024
26 September 2024
25 September 2024
Inte kategoriserad Manualer
- Backyard Discovery
- WAGAN
- FIMI
- Labelmate
- Sanitaire
- Ansco
- Dualit
- Perkins
- Petsafe
- BigBlue
- Zaahn
- NordicTrack
- Kerbl
- Deflecto
- Hapro
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025