Läs gratis den bruksanvisning för Panduit FMT1A (8 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 4 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 2.5 recensioner. Har du en fråga om Panduit FMT1A eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/8

For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2009 FS007A
CONTENTS: (#) indicates FMT2A quantity
OPTICOM QUICKNET Rack Mount Angled Fiber
Cassette Enclosures and Patch Panels
Part Numbers: FMT1A, FMT2A, CFAPPBL1A, CFAPPBL2A
1 - ENCLOSURE
1 (2) - #10-32 x 5/16" SCREWS
4 (5) - #10-32 HEX NUTS
4 - #12-24 x 1/2" SCREWS
4 - M6 x 1 SCREWS
3 - #10 FLAT WASHERS
1 (2) - CABLE ENTRY GROMMET(S)
1 (2) - STRAIN RELIEF BRACKET(S)
2 - ADHESIVE BEVEL ENTRY CLIPS
2 - ADHESIVE BACKED MOUNTS
4 - TAK-TYs (6" pcs.)
2 - SLACK SPOOLS (FMS1 or FMS2)
Cover (field removable)
Fiber Adapter Panels (FAPs):
Up to 4 for FMT1A
Up to 8 for FMT2A
(sold separately) Trunk or Interconnect
Cable Entry Grommet
Strain Relief Bracket
Enclosure
CFAPPBL1A
CFAPPBL2A
PG16 Gland
(customer supplied)
1 - CAUTION LABEL
1 - LASER WARNING LABEL
Page 1 of 8
Angled Patch Panel
(CFAPPBL1A shown)
FMT1A FMT2A
(sold separately)
(sold separately)
ASSEMBLY VIEW showing Fiber Adapter Panels (FAPs) - sold separately
CAUTION:
Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer’s cable specification sheet for
the specific cable in use.
Follow TIA/EIA-568A, 569, 606, and 607 installation guidelines where applicable.
Care should be taken when opening and closing fully loaded drawer in order to protect fiber components.
WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE
CONNECTOR. DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS.

For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2009 FS007A
Determine where the cable will enter the
enclosure. Carefully remove the knock-out so as
not to damage the surrounding sheet metal.
DO NOT install the grommet at this stage.
Grommet will be installed after the enclosure is
mounted to the rack.
To remove the cover, unscrew the #10-32 screw,
slide the cover back, lift up and off.
Preparation and Rack Mounting
Figure 3
#10-32 hex nuts and
#10 flat washers
#10-32 screw
Attach the angled patch panel to the enclsoure
with (2) #10 flat washers and (2) #10-32 hex nuts.
Page 2 of 8
Figure 2
Figure 1
Cover

For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2009 FS007A
(2) #12-24 x 1/2" screws
Repeat for other side.
Figure 4B
Angled Patch
Panel
(CFAPPBL1A shown)
Figure 4C
Angled patch panels may be mounted directly
to the rack without an enclosure. Place at the
desired position on the rack and secure with
(4) #12-24 x 1/2" screws.
Use (4) M6 x 1 screws if mounting to a metric
rack.
Page 3 of 8
Mount the enclosure to the rack using
(4) #12-24 x 1/2" screws.
Use (4) M6 x 1 screws if mounting to a metric
rack.
Mounting Brackets
Figure 4A
Place the mounting brackets at the desired
position on the rack.
Produktspecifikationer
Varumärke: | Panduit |
Kategori: | Inte kategoriserad |
Modell: | FMT1A |
Behöver du hjälp?
Om du behöver hjälp med Panduit FMT1A ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Panduit Manualer
1 Januari 2025
1 Januari 2025
1 Januari 2025
1 Januari 2025
30 December 2025
30 December 2025
30 December 2025
30 December 2025
15 December 2024
15 December 2024
Inte kategoriserad Manualer
- Niceboy
- Sharp
- AGM
- Comelit
- Crem
- Stewart Systems
- Middle Atlantic Products
- SatKing
- Sachtler
- Sirus
- Tevion
- OP/TECH
- Mercury
- Jumbo
- Intel
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025