Läs gratis den bruksanvisning för PCE Instruments PCE-MO 1500 (2 sidor) i kategorin Mätutrustning. Guiden har ansetts hjälpsam av 23 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 9 recensioner. Har du en fråga om PCE Instruments PCE-MO 1500 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
User Manual
Megohmmeter
PCE-MO 1500
SafetyRequirements&SafetyWarnings:
Thisseriesofinsulationresistancetesterisdesignedandproducedaccordingtothesafety
standardIEC1010.StrictlyfollowthesafetystandardsofdoubleinsulationCATIII1000V
CATIVandpollutiondegree2.Toprotectyoursafety,pleasereadthemanualbeforeusing
it.
SafetySymbolDescription:
Caution!Refertotheuser’smanualbeforeusingthismeter.DoubleInsulation
Warning!DangerousVoltage(Risk
ofelectricshock).
Danger:Toavoidseriousorfataldamagethatmaybecausedbycertainstatesandwrong
operations.
Warning:indicatesavoidingtheriskofelectricshock.
Caution:indicatesavoidingdamagetotheinstrumentandmakingaccuratemeasurements.
·Donottestinflammablelocations,sparksmaycauseanexplosion.
·Donotoperatetheinstrumentiftheinstrumentsurfaceiswetoriftheoperator'shands
arewet.
·Whentestingvoltage,thereisapossibilityofpersonalinjuryduetoaccidental
short-circuitbetweenmetalpartsandtestleads.
·Donotexceedthemaximumallowablerangeofthemeasuringrangeduringmeasure-
ment.
·Donotopenthebatterycoverduringmeasurement.
·Whenperforminginsulationmeasurement,donottouchthelineundertest.
Warning
·Iftheinstrumentisabnormal,pleasestopusingit.Forexample:Brokeninstrumentor
exposedmetalparts,pleasedonotuseitinthissituation.
·Whenthetestleadisinsertedintotheinstrumentinterfaceandconnectedtothecircuit
fortesting,donotpressthefunctionbutton,butexitthemeasurementfirst,andthen
changethetestitem.·
Donotinstallsubstitutepartsormakeanyunauthorizedchangestotheinstrument.
·Donotreplacethebatterywhentheinstrumentiswet.
·Makesurealltestleadsaresecurelyconnectedtothemeter'stestsockets.
·Makesuretheinstrumentisturnedoffbeforeopeningthebatterycover.
Caution:
·Beforemeasuring,confirmthatthefunctionbuttonisselectedtotheappropriate
position.
·Afteruse,pressandholdthe“OFF”buttontoturnofftheunit.Ifyoudonotuseit
foralongtime,pleasetakeoutthebatteryandstorageit.
·Donotstorageforalongtimeinhightemperature,humidity,placeswherecondensation
mayoccur,orindirectsunlight.
·Pleaseuseadampclothordetergenttocleantheinstrumentcase,donotuseabrasives
orsolventstowipethe
instrumentcaseandaccessories.
·Whentheinstrumentiswet,pleasedryitbeforeuseorstorage.
General:
Insulationresistancetester(orhighvoltageinsulationmeter)isaspecialinstrumentfor
measuringinsulationresistance.Itisanidealtestinstrumentformeasuringinsulation
resistanceoflargetransformers,transformers,generators,high-voltagemotors,power
capacitors,powercables,arresters,etc.
·Automaticreleasevoltagefunction.
·Suit
ableformeasuringinsulationresistanceofvariouselectricalequipmentand
insulatingmaterialssuchastransformers,motors,cables,switches,electricalappliances,etc.
Itissuitableforthemaintenance,repair,testandverificationofvariouselectrical
equipment.
·Ratedoutputvoltagevariable
Theratedoutputvoltagecanbeswitchedbythefunctionbuttons"▲""▼":
1000Vswitchesbetween50V,100V,250V,500V,1000V
2500Vswitchesbetween250V,500V,1000V,2000V,2500V.
5000Vswitchesbetween500V,1000V,2500V,5000V.
·Highvoltageindication
ThereisaredLEDlightinthemachineindicatingthatthereishighvoltageoutputinthe
instrument,thereisadangerofelectricshock,theoperatorshouldpayspecialattentionto
safety.
·Lowbatteryvoltageindication"".
·Battery-driven,easiertouse.
·2000digitswithbargraphdisplay,easytoreadthedata.
Measuringrange:
1000V:
0.1MΩ20GΩ~
2500V:1MΩ~200GΩ
5000V:10M~200GΩ,automaticrangeconversion.
·Easytooperateandcarry.
·Strongloadcapacity,<1.8mAoutputshort-circuitcurrent.
·Completeprotectioncircuit,notafraidofvoltagecounterattack,outputshort
circuitprotection.
·ItcanmeasureAC/DCvoltage10V-600V,ACvoltagefrequency40Hz~70Hz.
·Dust-proofandmoisture-proofstructure,suitableforoutdooroperation.
·Dimensions:180X140X70(mm)
·Weight:about800g(includingbattery)
A
.TechnicalData
Workinghumidityconditions:0°C~35°C,relative 75%
orless,2000metersabovesea
level
Outputvoltage:(output±10% load>=1000M)Ω
Short
circuitcurrent: aboutlessthan1.8mA;
Lowbatteryindication:Displayshows
Insulationresistance:>=500MΩ(1000V);
Withstandvoltage:AC2KV50Hz1minute;
Working
temperatureandworkinghumidity: temperature0°C~40°C,relative humidity
Table2.2500Vtechnicalparameters
Outputvoltage:±10%
250V/500V/1000V/2000V/2500V
B
.Appearance
1.InsulationresistancemeasurementhighvoltageoutputjackL
2.PositiveterminalofAC/DCvoltagemeasurement
3.VoltagemeasurementinputnegativeshieldingendG(shieldingend)
4.InsulationresistancemeasurementsamplingjackE