Läs gratis den bruksanvisning för Proel Flash 5A V2 (3 sidor) i kategorin högtalare. Guiden har ansetts hjälpsam av 21 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 11 recensioner. Har du en fråga om Proel Flash 5A V2 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/3
R&D Department
Testing Procedure
From PROEL R&D DEPT.
To PROEL SERVICE DEPT.
Object FLASH5 - A amplifier module TESTING PROCEDURE
Date 30 /20/04 14
Instruments required:
1) Sinusoidal audio signal generator
2) 100MHz or more dual trace oscilloscope (scope)
3) True RMS digital multimeter (DMM) with dBu scale
4) 250W or more Variac transformer with 0 250 Vac range (230V european version)-
or with 0- 140 Vac range (120V US version)
5) 4 Ω 1 00W or more resistive load
6) 8 Ω 5 0W or more resistive load
7) Music and pink noise signal generator (CD player)
IMPORTANT: The oscilloscope must be insulated from the earth ground.
1. Set up
- Check the correct earth main connection on the rear surface of the front panel.
- Check the insulation between the heat sink and the case of IC4, IC5 and IC3.
- Set the LINE LEVEL control full clockwise.
- position. Set the NEARFIELD/MIDFIELD button in NEARFIELD
- Switch OFF the amplifier module.
2. Low amplifier check
- Connect the mains of amplifier module to VARIAC and set it at zero AC voltage.
- Connect the scope CH1 GND clip to P8 black wire/faston (GND), scope CH1 probe tip to P6 red wire/faston
( ) LOW OUT and scope CH2 probe tip to P10 black wire/faston (HIGH OUT).
- Switch ON the amplifier module.
- Increase slowly the VARIAC voltage up to the nominal value (230Vac or 120Vac).
- Check the transformer secondary voltages with DMM (without signal on input):
52 ±2 Vac between red wire
32 ±2 Vac between yellow wire
- -Using DMM check also the +15Vdc / 15Vdc supplies on relative voltage regulator outputs (IC4 & IC5
devices).
- . Connect the signal generator to LINE INPUT (XLR/JACK socket) and set it at 100 Hz, -10 dBu
- . Verify that CH1 (LOW OUT) signal is 30V ±6 Vpp
- Check of SIGNAL/LIMIT LED function, moving the volume potentiometer of the amplifier;
when the output signal is < 2 Vpp the led must be OFF
when the output signal is > 2 Vpp, the led must be GREEN.
- lockwise. Rotate the volume potentiometer knob fully c
- u. Set the signal generator at 0 dB
- t Connect he 4 Ωload resistor at LOW OUT and verify that the signal is symmetrical refer to GND, without
detectable distortion and oscillation.