R&D Department
Testing Procedure
From PROEL R&D DEPT.
To PROEL SERVICE DEPT.
Object FLASH5- A amplifier module TESTING PROCEDURE
Date 30/20/0414
Instruments required:
1) Sinusoidal audio signal generator
2) 100MHz or more dual trace oscilloscope (scope)
3) True RMS digital multimeter (DMM) with dBu scale
4) 250W or more Variac transformer with 0250 Vac range (230V european version)-
or with 0- 140 Vac range (120V US version)
5) 4 Ω 1 00W or more resistive load
6) 8 Ω 5 0W or more resistive load
7) Music and pink noise signal generator (CD player)
IMPORTANT: The oscilloscope must be insulated from the earth ground.
1. Set up
- Check the correct earth main connection on the rear surface of the front panel.
- Check the insulation between the heat sink and the case of IC4, IC5and IC3.
- Set the LINE LEVELcontrol full clockwise.
- position. Set the NEARFIELD/MIDFIELDbutton in NEARFIELD
- Switch OFFthe amplifier module.
2. Low amplifier check
- Connect the mains of amplifier module to VARIAC and set it at zero AC voltage.
- Connect the scope CH1 GND clip to P8black wire/faston(GND), scope CH1 probe tip to P6 red wire/faston
() LOW OUTand scope CH2 probe tip to P10 black wire/faston (HIGH OUT).
- Switch ONthe amplifier module.
- Increase slowly the VARIAC voltage up to the nominal value (230Vac or 120Vac).
- Check the transformer secondary voltages with DMM (without signal on input):
52 ±2 Vac between red wire
32 ±2 Vac between yellow wire
- -Using DMM check also the +15Vdc / 15Vdc supplies on relative voltage regulator outputs (IC4 & IC5
devices).
- . Connect the signal generator to LINE INPUT (XLR/JACK socket) and set it at 100 Hz, -10 dBu
- . Verify that CH1 (LOW OUT) signal is 30V ±6 Vpp
- Check of SIGNAL/LIMIT LED function, moving the volume potentiometer of the amplifier;
when the output signal is < 2 Vpp the led must be OFF
when the output signal is > 2 Vpp, the led must be GREEN.
- lockwise. Rotate the volume potentiometer knob fully c
- u. Set the signal generator at 0dB
- t Connect he4 Ωload resistor at LOW OUT and verify that the signal is symmetrical refer to GND, without
detectable distortion and oscillation.
1
Produktspecifikationer
| Varumärke: | Proel |
| Kategori: | högtalare |
| Modell: | Flash 5A V2 |
Behöver du hjälp?
Om du behöver hjälp med Proel Flash 5A V2 ställ en fråga nedan och andra användare kommer att svara dig
högtalare Proel Manualer
Proel LT6A Bruksanvisning Proel V8 Plus Bruksanvisning Proel CS6TALEN Bruksanvisning Proel V15Plus Bruksanvisning Proel WX8A Bruksanvisning Proel V10Plus Bruksanvisning Proel WD10AV2 Bruksanvisning Proel Diva 15A Bruksanvisning
Populära i högtalare
högtalare Manualer
Nyaste högtalare Manualer
Pickering SOUNDKUB 160 Bruksanvisning Devine Axeo 8A Bruksanvisning Zvox AccuVoice AV835 Bruksanvisning Zvox AV855 Bruksanvisning Sunstech Go Beat Bruksanvisning Diamond Audio DES365C Bruksanvisning Denver BPS-370 Bruksanvisning Teufel Rockster 2 Rover Bruksanvisning JBL L100 Classic 80 Bruksanvisning Fluance Ri91 Bruksanvisning