Sharp SKMD30F0AS Bruksanvisning
Läs nedan 📖 manual på svenska för Sharp SKMD30F0AS (4 sidor) i kategorin Magnetron. Denna guide var användbar för 4 personer och betygsatt med 4.6 stjärnor i genomsnitt av 2.5 användare
Sida 1/4

E 1
C
N
H
E
F
D
A
B
J
L
I
M
K
G
Note: the face of the shelf must
sit 1 3/ "4 (44.45 mm) back from
the face of the cabinet.
cabinet face
shelf face O
24" Flush Mount DeFlector Vent: sKMD24F0As
INSTALLATION INSTRUCTIONS
1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.
CL
Top view
A
Anti-Tip block
Mounting cleat
BC
Drawer face Cabinet
face
Note: the mounting surface of the finished cleat must sit 1
1/ " (26.97 mm)16 back
from the face of the cabinet [pushing the face of the drawer out 1/ " (6.35 mm)4].
Figure 1
Figure 2A
Important notes to the Installer
• Read all of the Installation Manual that is included with
the Microwave Drawer before installing in the ush mount
conguration.
• Observe all governing codes, ordinances, and safety
instructions.
•Be sure to leave these instructions with the consumer.
Parts includes:
Qty. Part number
1
PREF-B019MRP0
Flush Mount
Deector Vent
2LX-CZB055MRE0
Mounting screws
T I N S EB 5 41M R R 2
A. 6" (152.40 mm)
B. Suggested electrical outlet location
C. Anti-Tip block
D. 5" (127 mm)
E. 3-1/2" (88.90 mm)
F. 4" (101.60 mm)
G. 24-3/16" (614.35 mm) minimum
24-1/2" (622.3 mm) maximum
H. 14-13/16" (376.24 mm) to bottom of
Anti-Tip block
I. 1-1/16" (26.97 mm)
J. 23-1/2" (596.90 mm) minimum depth
K. 22-1/8" (561.97 mm)
L. 1-3/4" (44.45 mm)
M. 16-7/8" (428.62 mm) opening
N. Floor must support 100 lb (45.4 kg)
O. 1-3/4" (44.45 mm)
A. 22" (558.8 mm) mounting cleat opening width
B. 1/4" (6.35 mm)
C. 1-1/16" (26.97 mm)

E 2
Shelf detail showing the deflector vent installed.
Shelf detail showing the deflector vent during installation.
Position deflector vent and mark holes. Pre drill using a
1/ " (1.57 mm) bit before mounting.16
C
Front view
No oven
B
A
Suggested electrical
outlet location Anti-Tip block
3/ "4 (19.05 mm)
shelf
Side view
1 3/ " (44.45 mm)4
front face of shelf
Front face of cabinet
16 7/ "8
(428.62 mm)
flush opening
height
Move oven location
downward for extended
countertops for better
viewing angle. Anti-Tip
block
3. Place the drawer adjacent to the wall or cabinet opening. Plug
the power supply cord into the electrical outlet.
4. Carefully guide the drawer into the prepared opening. Avoid
contact with the sides of the cutout opening and also pinching
the cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting anges
touch the cleats mounted in the cabinet opening.
6. Open the drawer. Using the 4 holes on the drawer as a template,
pre drill the cabinet using a 1/16” (1.57 mm) bit. See Figure 4.
Figure 3A
Figure 4
Figure 3B
2. Install deector as shown in Figure 3A.
7. Secure the drawer with the 4 screws supplied.
Mounting
flange
Figure 2B
Figure 2C
A. 22-1/8" (561.97 mm) mounting cleat opening width
B. 24-3/16" (614.35 mm) minimum
24-1/2" (622.3 mm) maximum
ush opening width
C. 3/4" (19.05 mm) shelf

E 3
C
N
H
E
F
D
B
A
J
L
I
cabinet face
shelf face O
G
K
M
Note: the face of the shelf must
sit 1 3/ "4 (44.45 mm) back from
the face of the cabinet.
30" Flush Mount DeFlector Vent: sKMD30F0As
INSTALLATION INSTRUCTION
1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.
CL
Top view
A
B C
Anti-Tip block
Mounting cleat
Drawer face Cabinet
face
Note: the mounting surface of the finished cleat must sit 1
1/ " (26.97 mm)16 back
from the face of the cabinet [pushing the face of the drawer out 1/ " (6.35 mm)4].
Figure 1
Figure 2A
Important notes to the Installer
• Read all of the Installation Manual that is included with
the Microwave Drawer before installing in the ush mount
conguration.
• Observe all governing codes, ordinances, and safety
instructions.
•Be sure to leave these instructions with the consumer.
Parts includes:
Qty. Part number
1
PREF-B020MRP0
Flush Mount
Deector Vent
2LX-CZB055MRE0
Mounting screws
A. 6" (152.40 mm)
B. Suggested electrical outlet location
C. Anti-Tip block
D. 5" (127 mm)
E. 3-1/2" (88.90 mm)
F. 4" (101.60 mm)
G. 30-5/16" (769.92 mm) minimum
30-5/8" (777.87 mm) maximum
H. 14-13/16" (376.24 mm) to bottom of
Anti-Tip block
I. 1-1/16" (26.97 mm)
J. 23-1/2" (596.90 mm) minimum depth
K. 28-7/16" (722.3 mm)
L. 1-3/4" (44.45 mm)
M. 16-7/8" (428.62 mm) opening
N. Floor must support 100 lb (45.4 kg)
O. 1-3/4" (44.45 mm)
A. 28-1/2" (723.9 mm) mounting cleat opening width
B. 1/4" (6.35 mm)
C. 1-1/16" (26.97 mm)
Produktspecifikationer
Varumärke: | Sharp |
Kategori: | Magnetron |
Modell: | SKMD30F0AS |
Behöver du hjälp?
Om du behöver hjälp med Sharp SKMD30F0AS ställ en fråga nedan och andra användare kommer att svara dig
Magnetron Sharp Manualer

8 Januari 2025

6 Januari 2025

24 December 2024

15 Oktober 2024

13 Oktober 2024

11 Oktober 2024

10 Oktober 2024

8 Oktober 2024

4 Oktober 2024

2 Oktober 2024
Magnetron Manualer
- Magnetron Hamilton Beach
- Magnetron De Dietrich
- Magnetron ACP
- Magnetron G3 Ferrari
- Magnetron Nabo
- Magnetron Brandt
- Magnetron Kogan
- Magnetron Emerio
- Magnetron Viva
- Magnetron Steba
- Magnetron AEG Electrolux
- Magnetron Cosmo
- Magnetron Bluesky
- Magnetron Pelonis
- Magnetron Esatto
Nyaste Magnetron Manualer

9 April 2025

9 April 2025

7 April 2025

7 April 2025

6 April 2025

6 April 2025

6 April 2025

5 April 2025

5 April 2025

5 April 2025