Sloan G2 Optima Plus Bruksanvisning

Sloan Inte kategoriserad G2 Optima Plus

Läs gratis den bruksanvisning för Sloan G2 Optima Plus (4 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 9 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 5 recensioner. Har du en fråga om Sloan G2 Optima Plus eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
Code No. 0816452
Rev. 6 (02/20)
G2/ECOS/SLOAN SINGLE FLUSH INSTALLATION INSTRUCTIONS FOR
RETROFIT AND COMPLETE VALVE INSTALLATION
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for
a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from the date of first purchase. During this period, Sloan Valve
Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole
and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs.
Damage caused by misuse or improper installation are all excluded from this warranty. This warranty extends only to person or organizations who purchase Sloan Valve Company’s
products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE
Prior to installing the Optima Plus flushometer, install the items listed below
as illustrated in the Rough-in Diagram. (New installations only.)
Closet or Urinal fixture
Drain line
Water supply line
Important:
ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN
ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
WHEN INSTALLING A FLUSHOMETER, IT IS IMPORTANT THAT
THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE
PLUMBING FIXTURE.
FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
The Optima Plus is designed to operate with 15 to 80 PSI (104 to 552 kPa)
of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE
VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
Consult fixture manufacturer for pressure requirements.
Most Low Consumption water closets (1.6 gallon/6 liter) require a minimum
flowing pressure of 25 psi (172 kPa).
8100 Series Complete Flushometer Models
8100 Series G2/ECOS/SLOAN valves are complete
flushometer valves and ideal for new installations.
RESS Series Retrofit Conversion Kit Models
RESS G2/ECOS/SLOAN models are used to convert existing
Royal, Regal and Sloan style flushometers to sensor activation.
G2/ECOS/SLOAN Water Closet Models can be furnished for the
following:
1.1 gpf/4.2 Lpf For High Efficiency Bowls
(ECOS combo unit only)
1.6 gpf/6.0 Lpf For Low Consumption Bowls
2.4 gpf/9.0 Lpf For 9 Liter European Water Closets
3.5 gpf/13.2 Lpf For older Water Closets
G2/ECOS/SLOAN Urinal Models can be furnished for the following:
0.125 gpf/1.9 Lpf For High Efficiency Urinal
(ECOS only)
0.25 gpf/1.9 Lpf For High Efficiency Urinal
(ECOS only)
0.5 gpf/1.9 Lpf For Wash Down Urinals
1.0 gpf/3.8 Lpf For Low Consumption Urinals
1.5 gpf/5.7 Lpf For older Siphon Jet Urinals
3.5 gpf/13.2 Lpf For older Blow Out Urinals
Made in the U.S.A.
PRIOR TO INSTALLATION
TOOLS REQUIRED FOR INSTALLATION
Slotted screwdriver to adjust control stop.
Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed
spud wrench for couplings.
Strap wrench (supplied) to install Optima Plus to valve body.
7/64” hex wrench (supplied) to secure Optima Plus cover to base plate.
With the exception of Control Stop Inlet, DO NOT
use pipe sealant or plumbing grease on any valve
component or coupling!
!!! IMPORTANT !!!
This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
!!! IMPORTANT !!!
When assistance is required, please contact
Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
or visit us online at: www.sloanvalve.com
2
VALVE ROUGH-IN
Typical Water Closet Installation
Model 8110/8111
Reference for RESS-C Retrofit
When installing the G2/ECOS in a handicap stall:
Per the ADA Guidelines (section 604.9.4) it is recommended that the grab bars
be split or shifted to the wide side of the stall.
2¼” (57 mm) MIN.
16½”
(419 mm)
C/L OF WASTE
FINISHED
WALL
FINISHED
FLOOR
2¼” (57 mm) MIN.
“Y”
C/L OF
WASTE
FINISHED WALL
FINISHED
FLOOR
C/L OF
FIXTURE
1” I.P.S.
(25 mm DN)
SUPPLY
4¾”
(121 mm)
High Rough-in Water Closet Installation
Models 8113, 8115 & 8116
“X”
Model 8115 & 8116 valves are designed for installations where
the water supply is roughed-in 24” - 27” (610 mm - 686 mm)
above the top of the water closet.
For new installations, Sloan strongly recommends the use of our
Model 8111 which has a shorter installation height.
Model “X” “Y”
8113 16” (406 mm) 21” (533 mm)
8115 24” (610 mm) 29” (737 mm)
8116 27” (686 mm) 32” (813 mm)
Typical Urinal Installation
Models 8180 & 8186
Reference for RESS-U Retrofit
2¼” (57 mm) MIN.
16½”
(419 mm)
C/L OF
FIXTURE
FINISHED
FLOOR
FINISHED
WALL
4¾”
(121 mm)
8180
1” I.P.S.
(25 mm DN)
SUPPLY
8186
¾” I.P.S.
(20 mm DN)
SUPPLY
C/L OF
FIXTURE
1” I.P.S.
(25 mm DN)
SUPPLY
4¾”
(121 mm)
11½”
(292 mm)
11½”
(292 mm)
The Strap Wrench provided with Optima Plus is a convenience
tool and is not to be used to remove or install the Flushometer
Couplings. Use Strap Wrench ONLY to install Optima Plus
Locking Ring.
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers
DO NOT USE toothed tools to install or service these valves.
Use a Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench
or smooth jawed spud wrench to secure all couplings. Also see
“Care and Cleaning” section of this manual.
!!! IMPORTANT !!!
LAWS AND REGULATIONS PROHIBIT THE USE OF
HIGHER FLUSHING VOLUMES THAN LISTED ON
FIXTURES OR FLUSHOMETERS.
!!! IMPORTANT !!!
3
A
Measure from finished wall
to C/L of Fixture Spud. Cut
pipe 1¼” (32 mm) shorter
than this measurement.
Chamfer O.D. and I.D. of
water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter
fully onto pipe.
C
Sweat solder the Adapter to pipe.
With the exception of Control Stop Inlet, DO NOT
use pipe sealant or plumbing grease on any valve
component or coupling!
!!! IMPORTANT !!!
BAK-CHEK
®
CONTROL STOP
COVER TUBE
IRON PIPE NIPPLE OR
COPPER PIPE WITH SWEAT
SOLDER ADAPTER
SET SCREW
SUPPLY
FLANGE
WATER
SUPPLY PIPE
SWEAT
SOLDER ADAPTER
COVER TUBE
WALL
FLANGE
A
Measure from finished
wall to first thread of
Adapter or threaded
supply pipe (dimension
“X”). Cut Cover Tube to
this length.
B
Slide Cover Tube over
pipe. Slide Wall Flange
over Cover Tube until
against wall.
Thread Control Stop
onto pipe. Tighten with a
wrench.
C
Tighten Set Screw with a 1/16”
hex wrench. DO NOT install Vandal
Resistant Stop Cap at this time.
D
1 - FOR COMPLETE VALVE INSTALLATION START HERE. FOR RESS RETROFIT
INSTALLATION, START AT STEP 6. INSTALL OPTIONAL SWEAT SOLDER ADAPTER
(ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)
2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE
3 - FLUSH OUT SUPPLY LINE
AOpen Control Stop.
CClose Control Stop.
BTurn on water supply to flush line of any debris or sediment.
“X”
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER GASKET
SPUD FLANGE
A
Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud
Flange over Vacuum Breaker Tube.
B
Insert Tube into Fixture Spud.
C
Hand tighten Spud Coupling onto Fixture Spud.
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER GASKET
SPUD FLANGE
MODELS
8110/8111,
8115, 8116
MODEL 8180 MODEL 8186
If cutting Vacuum Breaker Tube to size, note that
Critical Line (C/L) on Vacuum Breaker must typically
be 6” (152 mm) above fixture. Consult Code for details.
NOTE
4 - INSTALL VACUUM BREAKER FLUSH CONNECTION

Produktspecifikationer

Varumärke: Sloan
Kategori: Inte kategoriserad
Modell: G2 Optima Plus

Behöver du hjälp?

Om du behöver hjälp med Sloan G2 Optima Plus ställ en fråga nedan och andra användare kommer att svara dig