Läs gratis den bruksanvisning för Techno Line WS 6840 (2 sidor) i kategorin Väderstation. Guiden har ansetts hjälpsam av 6 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 3.5 recensioner. Har du en fråga om Techno Line WS 6840 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

LED Radio-Controlled Clock WS 6840
Key Features:
` DCF-77 radio controlled
` 12/24 H display.
` Time zone setting: -12 to +12 Hour.
` Dual Alarm with snooze function
` Indoor Temperature display in °C/°F
` Outdoor Temperature display in °C/°F
Power on or Reset:
` After power on or Reset, all LEDs turn on accordingly, buzzer beeps, unit enter RF Searching mode for Max. 3
minutes, then exit RF Searching mode and enter normal mode.
Clock setting:
` At normal mode, Press and hold the “MODE” key more than 2 seconds, can set 12/24HR Æ Æ Æ Hour Minute
Offset time.
` Corresponding icon flash at 1Hz, and press “UP” or “DOWN” ”key to set the value, and hold “UP” or “DOWN key for
fast increasing or decreasing.
` Press “MODE” key to confirm the setting and come to next setting, unit will return to Normal Mode after finish
setting.
F.Y.I.:
` At any other mode, if without key operation for 15 seconds, the unit will store current setting and return to Normal
Mode automatically.
` How to set Offset Time : Offset time means the time different between local time and Germany time; If local time is
1 hour faster than Germany time, then set the offset time to +1HR; If local time is 1 hour slower than Germany time,
then set the offset time to -1HR; Unit’s clock will automatically set to local time after receiving DCF signal
successfully.
Alarm Setting:
` At normal mode, Press “Mode” key to toggle the display among Clock Æ AL1 time Æ AL2 time, When AL1 or AL2
time be displayed ,press and hold “Mode” key more than 2 seconds to set Hour & Minute, corresponding icon
flash at 1Hz. press “UP” or “DOWN” key to set the value, and hold “UP” or “DOWN”key for fast increasing or
decreasing.
` When AL1 or AL2 icon flash, Press “Down” key to enable(Corresponding Alarm LED turn on) or
disable(Corresponding Alarm LED turn off) alarm. Unit will return to normal mode after finish setting
` Alarm sound crescendo for 2 minutes.
` During alarm, press “SNOOZE” key to stop the alarm and enable snooze function (Corresponding Alarm LED flash
at this status), the unit will alarm 5 minutes later.
` During alarm or Snooze function enable, press any other keys except “SNOOZE” key, will cancel the alarm or
Snooze function.
Indoor Temperature Measurement:
` Indoor Temperature measurement range: -9°C ~ +49°C, “LLL” will displayed if value lower than -9°C, “HHH” will

displayed if value higher than +49°C, resolution is 1°C/℉,accuracy is +/-1.5°C at 0°C ~ +40°C.
` Indoor temperature will be measured interval 30 seconds.
` At normal mode, press “DOWN“ key to select °C or °F.
` At normal mode, press “MEMORY“ key to display Max. or Min. indoor & outdoor temperature, Memory will cleared
if press & hold “MEMORY“ key more than 2 seconds.
RCC Receiving:
` At 1:00 /2:00 / 3:00 am, unit will automatically receive Ra , corresponding LED flash; If dio signal for Max. 7 minutes
receive successfully, Clock will be synchronized and RCC LED be on, otherwise RCC LED be off ;
` Press and hold the “WAVE“ key can enable or disable the RCC receiving manually.
F.Y.I.:
` We recommend a minimum distance of 2.5 meters to all sources of interference, such as televisions or computer
monitors
` Radio receiving is weaker in rooms with concrete walls (e.g.: in cellars) and in offices. In such extreme
circumstances, place the unit close to the window.
RF Receiving:
` At RF searching mode, “--.-” icons flash, unit will receive the RF signal from Outdoor Temperature Transmitter,
When outdoor temperature value be displayed ,indicate that the transmitter have been registered, and main unit
will exit RF searching mode immediately.
` Main unit only can register 1pc Transmitter.
` Transmission distance is up to 30m.
` If main unit display “--.-” ( Not flash ), it means that the transmitter have been lost link. Please press and hold
“UP“ key to enter RF searching mode (“--.-” icons flash ) to search the transmitter!
` When Outdoor Temperature Transmitter in Low Battery, “LO” (Indicate Transmitter in Low Battery status) &
“Temperature Value” will be displayed alternatively.
F.Y.I.:
` If Transmitter lost link frequently, please move the Transmitter close to main unit!
Weather Forecast:
` Weather forecast include Sunny / Partly Cloudy / Cloudy / Rainy.
Remarks:
1, To save power, when powered by batteries only, the unit will turn off display. And display turn on for 10
seconds if press any keys except “WAVE“ key.
2, Display will be always on if powered by adapter.
3, During RCC receiving, to lower interference , all LEDs off except RCC LED flash .
Produktspecifikationer
Varumärke: | Techno Line |
Kategori: | Väderstation |
Modell: | WS 6840 |
Färg på produkten: | Zwart |
Inbyggd display: | Ja |
Vikt: | 3800 g |
Bredd: | 300 mm |
Djup: | 240 mm |
Höjd: | 240 mm |
Antal lampor: | 7 lampen |
Typ av lampa: | LED |
Strömlampa: | 10 W |
Kraftkälla: | AC |
Monteringsverktyg: | Ja |
Inkluderar AC-adapter: | Ja |
Kylsystem: | Dynamisch (door de ventilator ondersteund) |
Inspänning: | 90 - 240 V |
Justerbar hastighet: | Ja |
Färg ljus: | Blue, Green, Red, White |
Frekvens: | 50/60 Hz |
Panoreringsintervall: | 0 - 540 ° |
Lämplig för inomhusbruk: | Ja |
Strömförbrukning (typiskt): | 80 W |
Tiltvinkelområde: | 0 - 270 ° |
Dimmer för ljusintensiteten: | Ja |
Ljuslägen: | DMX, Master/slave, Stand-alone |
Dimbereik: | 0 - 100 procent |
DMX-ingång: | Ja |
DMX-utgång: | Ja |
Antal stift: | 3 |
Baldiameter: | - " |
Antal DMX-kanaler: | 14 kanalen |
Minsta antal DMX-kanaler: | 9 kanalen |
Behöver du hjälp?
Om du behöver hjälp med Techno Line WS 6840 ställ en fråga nedan och andra användare kommer att svara dig
Väderstation Techno Line Manualer
5 Januari 2025
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
Väderstation Manualer
- Auriol
- Konyks
- IT
- Lexibook
- Oregon Scientific
- Marathon
- Setti+
- Browin
- Brandson
- Garni
- Bresser
- GoGEN
- Elgato
- Ade
- EVE
Nyaste Väderstation Manualer
2 April 2025
27 Mars 2025
27 Mars 2025
5 Mars 2025
27 Februari 2025
15 Februari 2025
5 Februari 2025
27 Januari 2025
27 Januari 2025
12 Januari 2025