LOG200 Precision, High-Speed Logarithmic Amplifier
With Integrated Photodiode Bias
1 Features
Ultra-fast transient response to low current levels:
Settling time for 10nA to 100nA step:
240ns rising, 620ns falling (typ)
Settling time for 100nA to 1μA step:
60ns rising, 150ns falling (typ)
Wide dynamic range: 10pA to 10mA (180dB)
Specified from 100pA to 10mA (160dB)
High signal bandwidth:
20MHz at 10µA to 10mA
6.3MHz at 1μA
90kHz at 1nA
High-accuracy transfer function:
0.2% max log conformity error (10nA to 100µA)
Integrated reference current (1μA) and reference
voltages (2.5V and 1.65V)
Additional auxiliary high-speed op amp for
differential ADC drive, single-ended gain or filter
blocks, and other peripheral functions
Single supply (4.5V to 12.6V) or
dual supply (±2.25V to ±6.3V) operation
Specified temperature range: –40°C to +125°C
Small package options:
3mm × 3mm VQFN
1.6mm x 1.6mm DSBGA (Preview)
2 Applications
Optical modules
Inter-DC interconnect
Optical network terminal unit
Chemistry/gas analyzer
Erbium-doped fiber optic amplifier (EDFA)
+
+
+
I2
I1
PD
Bias
IBIAS
VCM
+
REFGND
+
2.5V1.65V
REF25REF165
+
REFA
OUTA
OUTB
–IN +IN
VS+
VS–
VS+
1μA
IREF
LOG200 Device Schematic
3 Description
The LOG200 is a wide-dynamic-range current-to-
voltage amplifier specifically designed to optimize
current measurements across 160dB of dynamic
range with unparalleled accuracy and speed
for optical communications, medical diagnostics,
and industrial process-control measurements. The
LOG200 features two logarithmic amplifiers followed
by a high-accuracy differential amplifier that convert
current signals into a voltage representing the log-
compressed ratio of the two currents. The current
inputs are designed to feature a high-speed response
from one input, and a highly accurate reference
signal on the other input, allowing for a unique
combination of fast transient response and high
logarithmic conformity.
The LOG200 ratio is internally set to 250mV/
decade of current-to-voltage conversion. The device
integrates an uncommitted high-speed amplifier to
allow the output to be configured for differential or
filtered responses, with a fast settling time to drive
successive approximation analog-to-digital converters
(SAR ADCs). The LOG200 also features a separate
reference current and reference voltage designed to
configure the device for optimized input current and
common-mode voltages.
The LOG200 can be powered in a single-supply
(4.5V to 12.6V) or dual-supply (±2.25V to ±6.3V)
configuration and is specified from –40°C to +125°C.
Package Information
PART NUMBERPACKAGE
(1)
PACKAGE SIZE
(2)
LOG200
RGT (VQFN, 16)3mm × 3mm
YBH (DSBGA, 16)
(3)
1.6mm × 1.6mm
(1)For more information, see Section 10.
(2)The package size (length × width) is a nominal value and
includes pins, where applicable.
(3)Preview information (not Production Data).
LOG200
SBOSA28A – AUGUST 2023 – REVISED DECEMBER 2024
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. UNLESS OTHERWISE NOTED, this document contains PRODUCTION
DATA.