Installation Guide
Unmanaged/Easy Smart Rackmountable Switches
Business Networking Solution


About this Installation Guide
This Installation Guide describes the hardware characteristics, installation methods and the
points that should be attended to during installation. This Installation Guide is structured as
follows:
Chapter 1 Introduction
This chapter describes the external components of the switch.
Chapter 2 Installation
This chapter illustrates how to install the switch.
Chapter 3 Connection
This chapter illustrates how to do the physical connection of the switch.
Appendix A Troubleshooting
Appendix B Hardware Specifications
Audience
This Installation Guide is for:
Network Engineer Network Administrator
Conventions
• When using this guide, notice that features available in TP-Link | Omada series products may vary
by model and software version. Availability of TP-Link | Omada series products may also vary
by region or ISP. All images, steps, and descriptions in this guide are only examples and may not
reflect your actual experience. Some models featured in this guide may be unavailable in your
country or region. For local sales information, visit https://www.tp-link.com.
• The speed of the ports in Extend Mode will downgrade to 10 Mbps. The actual transmission
distance may vary due to power consumption of PoE-powered devices or the cable quality and
type.
• PoE budget calculations are based on laboratory testing. Actual PoE power budget is not
guaranteed and will vary as a result of client limitations and environmental factors.
• This guide uses the specific formats to highlight special messages. The following table lists the
notice icons that are used throughout this guide.
Remind to be careful. A caution indicates the potential which may result in device damage.
Remind to take notice. The note contains the helpful information for the better use of the
product.
Related Document
This Installation Guide is also available in PDF on our website. To obtain the latest
documentation and product information, visit the official website: https://www.tp-link.com.

7
Unmanaged/Easy Smart Rackmountable Switches
Installation
Keep the equipment room at an appropriate level of temperature and humidity. Too much or too
little humidity may lead to bad insulation, leakage of electricity, mechanical property changes,
and corrosion. High temperatures may accelerate aging of the insulation materials, significantly
shortening the service life of the device. To find out the best temperature and humidity conditions
for the device, check the following table.
Environment Temperature Humidity
Operating
0 °C to 50 °C
(for DS1018GMP)
0 °C to 40 °C (for other models)
10% to 90%RH Non-condensing
Storage 5% to 90%RH Non-condensing-40 °C to 70 °C
Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact
of metal contact points. Some measures have been taken for the device to prevent static electricity,
but too strong static electricity can cause deadly damage to the electronic elements on the internal
circuit board. To avoid the effect of static electricity on the operation of the switch, attach much
importance to the following items:
■Dust the device regularly, and keep the indoor air clean.
■Keep the device well grounded and ensure that the static electricity has been transferred.
Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected by external
interferences, such as conducted emission by capacitance coupling, inductance coupling, and
impedance coupling. To decrease the interferences, make sure to take the following measures:
■Use the power supply that can effectively filter interference from the power grid.
■Keep the device far from high-frequency and strong-current devices such as radio transmitting
station.
■Use electromagnetic shielding when necessary.
Lightning Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air in the
electric discharge path can be instantly heated up to 20,000 °C. As this instant current is strong
enough to damage electronic devices, more effective lightning protection measures should be
taken.
■Ensure that the rack and the device are well earthed.

8
Unmanaged/Easy Smart Rackmountable Switches
Installation
■Make sure the power socket has a good contact with the ground.
■Keep a reasonable cabling system and avoid induced lightning.
■Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note:
For detailed lightning protection measures, refer to the Lightning Protection Guide from the
Related Documents of our website:
https://www.tp-link.com/us/conguration-guides/lightning_protection_guide.
Installation Site
When installing the device on a rack or a flat workbench, attach much importance to the following
items:
■The rack or workbench is flat, stable, and sturdy enough to support the weight of 5.5 kg at least.
■The rack or workbench has a good ventilation system. The equipment room is well ventilated.
■The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Installation Tools
■Phillips screwdriver
■ESD-preventive wrist wrap
■Cables
Note:
These tools are not included with our product. If needed, you can purchase them separately.
2.4 Product Installation
■Desktop Installation
To install the device on the desktop, follow the steps:
1. Set the device on a flat surface which is strong enough to support the entire weight of the device
with all fittings.
2. Remove the adhesive backing papers from the rubber feet.
3. Turn over the device and attach the supplied rubber feet to the recessed areas on the bottom at
each corner of the device.

10
Unmanaged/Easy Smart Rackmountable Switches
Connection
Chapter 3 Connection
3.1 Ethernet Port
Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows.
Figure 3-1 Connecting the RJ45 Port
RJ45 Port RJ45 Cable
3.2 SFP Port
The following figure demonstrates the connection of SFP port to an SFP module.
Figure 3-2 Inserting the SFP Module
SFP Slot
SFP Module
Note:
DS1018GMP has 2 SFP ports which support 1000 Mbps SFP module connection.
3.3 Verify Installation
After completing the installation, verify the following items:
■There should be 5 to 10 cm of clearance around the device for ventilation and make sure the air flow is
adequate.
■The voltage of the power supply meets the requirement of the input voltage of the device.

11
Unmanaged/Easy Smart Rackmountable Switches
Connection
■The power socket, device and rack are well grounded.
■The device is correctly connected to other network devices.
3.4 Power On
Plug the negative connector of the provided power cord into the power socket of the device and plug
the positive connector into a power outlet as the following figure shows.
Figure 3-3 Connecting to Power Supply
Note:
The gure is to illustrate the application and principle. The provided plug and the socket in
your region may dier from the gures above.
3.5 Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically
to ensure the device functions properly. During this time, the LED indicators will respond as follows:
1. The PWR/Power LED indicator will light up.
2. The LED indicators of all the por ts will flash momentarily and then turn off again after the
initialization.
3.6 Accessing the Switch
Note:
Only for DS1016GE/DS1024GE, you can access and manage the switch.
After the initialization finished, you can access and manage the switch using the Web-based GUI
(Graphical User Interface) or using the Configuration Utility.
Using the Web-Based GUI
To access and manage the switch using the Web-Based GUI, take the following steps:
1. Find the IP address of the switch.
■By default, the switch receives an IP address from a DHCP server (or a router that functions as a
DHCP server) in your network. You can find this IP address on the DHCP server.
■If the switch cannot receive an IP address from a DHCP server, it uses the static IP address of
192.168.0.1, with a subnet mask of 255.255.255.0.
Produktspecifikationer
Varumärke: | TP Link |
Kategori: | Inte kategoriserad |
Modell: | Omada DS1016GE |
Behöver du hjälp?
Om du behöver hjälp med TP Link Omada DS1016GE ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad TP Link Manualer

20 Februari 2025

17 Februari 2025

17 Februari 2025

28 Januari 2025

28 Januari 2025

25 Januari 2025

8 Januari 2025

3 Januari 2025

3 Januari 2025

3 Januari 2025
Inte kategoriserad Manualer
- Inte kategoriserad Comtek
- Inte kategoriserad Tece
- Inte kategoriserad Maturmeat
- Inte kategoriserad IKEA
- Inte kategoriserad CELLFAST
- Inte kategoriserad Adobe
- Inte kategoriserad Lantus
- Inte kategoriserad Fujitsu
- Inte kategoriserad Volvo
- Inte kategoriserad Stamony
- Inte kategoriserad Narva
- Inte kategoriserad Axis
- Inte kategoriserad Topex
- Inte kategoriserad Create
- Inte kategoriserad Peltor
Nyaste Inte kategoriserad Manualer

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025