Läs gratis den bruksanvisning för Tripp Lite Metered PDUMH15-ISO (12 sidor) i kategorin Elskena. Guiden har ansetts hjälpsam av 5 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 3 recensioner. Har du en fråga om Tripp Lite Metered PDUMH15-ISO eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/12
1
Metered Rack PDU
Important Safety Instructions 2
Important Warnings 2
Installation 3
Features 4
Warranty & Warranty Registration 4
Español 5
Français 9
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved.
14-02-330-932567.indb 1 4/23/2014 3:58:20 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will void the
product warranty.
Important Warnings
• ThePDUprovidesconvenientmultipleoutletsbutitDOESNOTprovidesurgeor
linenoiseprotectionforconnectedequipment.
• ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfromexcessmoisture,
temperatureextremes,conductivecontaminants,dustordirectsunlight.
• DonotconnectthePDUtoanungroundedoutletorextensioncordsoradaptersthateliminate
theconnectiontoground.
• ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmustnotexceedthe
individualoutlet’sloadrating.
• ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceedthe
maximumloadratingforthePDU.
• DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-serviceable
partsinside.
• DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
• DonotattempttousethePDUifanypartofitbecomesdamaged.
• DonotattempttomountthePDUtoaninsecureorunstablesurface.
• Neverattempttoinstallelectricalequipmentduringathunderstorm.
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentortosignificantly
affectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthe
presenceofaflammableanestheticmixturewithair,oxygenornitrousoxide.
14-02-330-932567.indb 2 4/23/2014 3:58:20 PM
3
Installation
Note: The illustrations may differ somewhat from your PDU
model.
1
Determine Installation Configuration.ThePDU
supportsfourprimaryinstallationconfigurations:1U
Rack,0URack,WallandUnder-Counter.Choosea
configurationandfollowtheinstallationinstructions
intheappropriatesectionofStep1before
proceedingtoStep2.
Note: Regardless of installation configuration, the
user must determine the fitness of hardware and
procedures before mounting. The PDU and included
hardware are designed for common rack and rack
enclosure types and may not be appropriate for all
applications. Exact mounting configurations may vary.
1-1
1U Rack Installation.AttachthePDUtotherackby
insertingfouruser-suppliedscrews(A)throughthe
PDUmountingbrackets(B)andintothemounting
holesoftherackrailasshown.
1-2
0U Rack Installation. Part 1:Removethescrews
(C)attachingthemountingbracketstothePDU,
changetheorientationofthebracketsasshownand
reattachthebrackets.Useonlythescrewssupplied
bythemanufacturerortheirexactequivalent(#6-
32,1/4”flathead). Part 2:AttachthePDUvertically
byinsertingtwoormoreuser-suppliedscrews(A)
throughthePDUmountingbrackets(B)andinto
mountingpointsintherackorrackenclosure.
1-3
Wall Installation. AfterrepeatingPart1above,
attachthePDUtoastablemountingsurfaceby
insertingtwoormoreuser-suppliedscrews(A)
throughthePDUmountingbrackets(B)andinto
securemountingpointsonthemountingsurface.
1-4
Under-Counter Installation. AfterrepeatingPart1
above,attachthePDUtoastablemountingsurface
byinsertingfouruser-suppliedscrews(A)throughthe
PDUmountingbrackets(B)andintosecuremounting
pointsonthemountingsurface.
2
Attach the input plug of the PDU to a grounded
outlet. Inserttheplugdirectlyintoagroundedoutlet
thatdoesnotshareacircuitwithaheavyelectrical
load(suchasanairconditionerorrefrigerator).
2
1-1
1-2
1-3
1-4
A
B
B
A
C
A
B
C
B
C
A
C
3
Note: Select models include an input plug adapter that converts the twist-lock input plug to a
straight-blade input plug. Attach the input plug adapter to the input plug if you wish to plug
the PDU into a compatible straight-blade outlet.
3
Attach equipment to the PDU. DonotexceedtheloadratingofthePDU.Thetotalelectrical
currentusedbythePDUwillbedisplayedonthedigitalmeterinamperes.
14-02-330-932567.indb 3 4/23/2014 3:58:22 PM

Produktspecifikationer

Varumärke: Tripp Lite
Kategori: Elskena
Modell: Metered PDUMH15-ISO
Vikt: 2090 g
Bredd: 50.8 mm
Djup: 114.3 mm
Höjd: 57.2 mm
Förpackningens bredd: 520.7 mm
LED-indikatorer: Status
Ursprungsland: Kina
Certifiering: UL1449, CSA
Modell: Enfas
Montage: Horisontell / Vertikal
Rackkapacitet: 0U/1U
Överspänningsskydd: Ja
Kabellängd: 4.5 m
Produktens färg: Svart
Låddjup: 254 mm
Vikt inkl. förpackning: 2650 g
Ytterförpackningens bruttovikt: 14610 g
Ytterförpackningens höjd: 247.6 mm
Produkter per ytterförpackning: 6 styck
Ytterförpackningens längd: 349.2 mm
Ytterkartong GTIN (EAN/UPC): 10037332183245
Ytterförpackningens bredd: 527 mm
Effekt skyddsfunktioner: Överbelastning
Temperaturintervall (förvaring): -30 - 50 ° C
Intervall för relativ operativ luftfuktighet: 5 - 95 %
Hållbarhetscertifiering: RoHS
Utgångsspänning: 100; 120; 127 V
Material, hölje: Metall
Växelström Frekvens: 50 - 60 hz
Displaytyp: LCD
Högsta strömstyrka: 15 A
Antal uttag AC: 14 AC-utgångar
Altitud vid drift: 0 - 3000 m
Maximal styrka: 1520 W
Energivärdering: 3840 J
AC försäljningsställen: NEMA 5–15R
EMI / RFI-brusfiltrering: Ja
Uttag: NEMA L5-15P
Ingångsspänning (Volt): 100; 120; 127 V
Belastningskapacitet: 140 VA
PDU typer: Mätt