Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA
773.869.1234 (USA) • 773.869.1212 (International)
www.tripplite.com
Important Safety Instructions 2
Installation 3
Basic Operation 5
Battery Replacement 11
Storage and Service 11
SmartOnline
True On-Line Tower UPS Systems
Warranty Registration 12
Espol
Français 25
13
Copyright ©2009 Tripp Lite. All rights reserved. SmartOnline
is a trademark of Tripp Lite.
Troubleshooting 9
Warranty
Registration:
register online today for a chance
to win a FREE Tripp Lite product—
www.tripplite.com/warranty
Not suitable for mobile applications.
2
UPS Location Warnings
• InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,
dustordirectsunlight.
• Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand
40ºC).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• Donotmountunitwithitsfrontorrearpanelfacingdown(atanyangle).
 Mountinginthismannerwillseriouslyinhibittheunit’sinternalcooling,eventually
 causingproductdamagenotcoveredunderwarranty.
UPS Connection Warnings
• ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.Donotplugthe
UPSintoitself;thiswilldamagetheUPS.
• DonotmodifytheUPS'splug,anddonotuseanadapterthatwouldeliminatetheUPS’s
groundconnection.
• DonotuseextensioncordstoconnecttheUPStoanACoutlet.Yourwarrantywillbe
voidedifanythingotherthanTrippLitesurgesuppressorsareusedtoconnectyourUPS
to an outlet.
• IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormust
provideclean,filtered,computer-gradeoutput.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
significantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaflammableanestheticmixturewithair,oxygenornitrous
oxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.This
mightdamagetheUPSandwillvoidthesurgesuppressorandUPSwarranties.
Battery Warnings
Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.
Observeproperprecautions.Donotdisposeofthebatteriesinafire.DonotopentheUPS
orbatteries.Donotshortorbridgethebatteryterminalswithanyobject.Unplugandturn
offtheUPSbeforeperformingbatteryreplacement.Usetoolswithinsulatedhandles.
Therearenouser-serviceablepartsinsidetheUPS.Batteryreplacementshouldbe
performedonlybyauthorizedservicepersonnelusingthesamenumberandtypeof
batteries(SealedLead-Acid).Thebatteriesarerecyclable.Refertoyourlocalcodesfor
disposalrequirementsorintheUSAonlycall1-800-SAV-LEADor1-800-8-BATTERY
(1-800-822-8837)orvisitwww.rbrc.comforrecyclinginformation.TrippLiteoffersa
completelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteon
theWebatwww.tripplite.com/support/battery/index.cfmtolocatethespecificreplacement
batteryforyourUPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation,operationandstorageofallTrippLiteUPSSystems.Failuretoheedthese
warningswillvoidyourwarranty.
2
Important Safety Instructions
1
2
3
1
33
Important Safety Instructions
Connection and Start-Up
Plug your UPS’s line cord into an
electrical outlet.
Your UPS must be connected to a dedicated
circuit of sufficient amperage.Note,however,
that the select models may be fitted with
differentplugtypes.Refertothe“OPRating/
PlugRating”chartprinted onthetopof your
UPS.
OnceyourUPSisplugged in,thefanandall
IndicatorLightswillturnON.The“LINE”and
LOADACTIVEMETER”LEDswillilluminate
andtheUPSwillemitabeeptoindicatenormal
operation. However, power is not supplied to
your UPS’sAC outletsuntil theUPS isturned
on.
Plug your equipment into your UPS.
Your UPS is designed to support computer
equipmentonly.YouwilloverloadyourUPSif
you connect household appliances or laser
printerstotheUPS'soutlets.
Turn your UPS ON:
• Pressthe“ON/TEST”Button
• Holditforseveralsecondsuntilyou
 hearabeep
• Releaseit
Your UPS will begin providing AC power to its outlets.
The “ON LINE” LED will illuminate.
Your UPS will function properly without these
connections.
Phone Line or Phone/Network
Line Surge Suppression
Your UPS has jacks which protect against
surges on a phone or network line.* Using
appropriate network cords connect your wall
jack to the UPS jack marked “IN.” Connect
your equipment to the UPS jack marked
“OUT.”Makesuretheequipmentyouconnect
to the UPS's jacks is also protected against
surgesontheACline.
*NotcompatiblewithPoE(PowerOverEthernet)applications.
Your model may differ.
1
2
3
Your model
may differ.
Installation
Optional Connections
1
Your model may differ.

Produktspecifikationer

Varumärke: Tripp Lite
Kategori: UPS
Modell: SU1000XLA

Behöver du hjälp?

Om du behöver hjälp med Tripp Lite SU1000XLA ställ en fråga nedan och andra användare kommer att svara dig




UPS Tripp Lite Manualer

UPS Manualer

Nyaste UPS Manualer