Trotec BA30WP Bruksanvisning


Läs gratis den bruksanvisning för Trotec BA30WP (16 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 24 personer och har ett genomsnittsbetyg på 4.2 stjärnor baserat på 12.5 recensioner. Har du en fråga om Trotec BA30WP eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/16
TRT-BA-BA30WP-TC220325TTRT06-007-EN
BA30WP
EN
INSTRUCTIONS
HOT-WIRE ANEMOMETER
CONTROLLED VIA SMARTPHONE
2 EN
hot-wire anemometer controlled via smartphone BA30WP
Table of contents
Information on the use of these instructions .......................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................5
Operation ...............................................................................6
Maintenance and repair ......................................................14
Errors and faults..................................................................14
Disposal ...............................................................................15
Declaration of conformity ...................................................15
Information on the use of these instructions
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Notice
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
BA30WP
https://hub.trotec.com/?id=43337
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
Do not use the device in potentially explosive rooms or
areas and do not install it there.
Do not use the device in an aggressive atmosphere.
Do not immerse the device in water. Do not allow liquids to
penetrate into the device.
The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.
Protect the device from permanent direct sunlight.
Do not expose the device to strong vibrations.
Do not open the device.
Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
Use batteries of typeAAA.
Never charge batteries that cannot be recharged.
Different types of batteries and new and used batteries
must not be used together.
Insert the batteries into the battery compartment according
to the correct polarity.
Remove discharged batteries. Batteries contain materials
hazardous to the environment. Dispose of the batteries
according to the national regulations.
Remove the batteries from the device if you will not be
using the device for a longer period of time.
Never short-circuit the supply terminal in the battery
compartment!
EN 3
hot-wire anemometer controlled via smartphone BA30WP
Do not swallow batteries! If a battery is swallowed, it can
cause severe internal burns within2hours! These burns
can lead to death!
If you think batteries might have been swallowed or
otherwise entered the body, seek medical attention
immediately!
Keep new and used batteries and an open battery
compartment away from children.
Observe the storage and operating conditions (see
Technical data).
Intended use
Use this device in combination with a terminal device that is
compatible with the installed Trotec MultiMeasure Mobile app.
Only use the device for measurements of air velocity, volumetric
flow, air temperature and relative humidity within the measuring
range specified in the technical data. Observe and comply with
the technical data.
The Trotec MultiMeasure Mobile app on the terminal device is
used for both operation and the evaluation of the measured
values.
Data logged by the device can be displayed, saved or
transmitted either numerically or in form of a chart.
Any use other than the intended use is regarded as misuse.
Reasonably foreseeable misuse
Do not use the device in potentially explosive atmospheres, for
measurements in liquids or on live parts.
Radio waves may interfere with the operation of medical
equipment and cause malfunctions. Do not use the device near
medical equipment or within medical institutions.
Persons with pacemakers must observe a minimum distance of
20cm between the pacemaker and the device.
Also do not use the device near automatically controlled
systems such as alarm systems and automatic doors. Radio
waves may interfere with the operation of such equipment and
cause malfunctions. Make sure that no other devices are
malfunctioning during the use of your device.
Any unauthorised changes, modifications or alterations to the
device are forbidden.
Personnel qualification
People who use this device must:
have read and understood the instructions, especially the
Safety chapter.
Safety signs and labels on the device
Notice
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Warning of magnetic field
Information marked with this symbol indicates dangers
to the life and health of persons due to magnetic fields.
Disrupted operation or damage to pacemakers and
implanted defibrillators caused by the device
This symbol indicates that the device must be kept
away from pacemakers or implanted defibrillators.
Residual risks
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning
Magnetic field!
The magnet attachment can affect pacemakers and
implanted defibrillators!
Always keep a minimum distance of 20cm between
the device and pacemakers or implanted defibrillators.
Persons with pacemakers or implanted defibrillators
must not carry the device in their breast pocket.
Warning
Risk of damages or data loss due to magnetic field!
Do not store, carry or use the device in the vicinity of
data storage media or electronic devices such as hard
drives, television units, gas meters or credit cards!
There is a risk of data loss or damages. If possible,
keep the highest safety distance possible (at
least1m).


Produktspecifikationer

Varumärke: Trotec
Kategori: Inte kategoriserad
Modell: BA30WP

Behöver du hjälp?

Om du behöver hjälp med Trotec BA30WP ställ en fråga nedan och andra användare kommer att svara dig