Läs gratis den bruksanvisning för Trotec BZ26 (10 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 12 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 6.5 recensioner. Har du en fråga om Trotec BZ26 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/10

TRT-BA-BZ26-TC220429TTRT01-002-EN
BZ26
EN
INSTRUCTIONS
CO AIR QUALITY MONITOR₂

2 EN
CO₂ air quality monitor BZ26
Table of contents
Information on the use of these instructions .......................2
Safety .....................................................................................2
Information about the device................................................3
Transport and storage...........................................................5
Operation ...............................................................................6
Maintenance and repair ........................................................9
Disposal ...............................................................................10
Information on the use of these instructions
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Notice
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
BZ26
https://hub.trotec.com/?id=46639
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in an aggressive atmosphere.
• Do not immerse the device in water. Do not allow liquids to
penetrate into the device.
• The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.
• Protect the device from permanent direct sunlight.
• Do not open the device.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Use batteries of typeAAA.
• Never charge batteries that cannot be recharged.
• Different types of batteries and new and used batteries
must not be used together.
• Insert the batteries into the battery compartment according
to the correct polarity.
• Remove discharged batteries. Batteries contain materials
hazardous to the environment. Dispose of the batteries
according to the national regulations.
• Remove the batteries from the device if you will not be
using the device for a longer period of time.
• Never short-circuit the supply terminal in the battery
compartment!

EN 3
CO₂ air quality monitor BZ26
• Do not swallow batteries! If a battery is swallowed, it can
cause severe internal burns within2hours! These burns
can lead to death!
• If you think batteries might have been swallowed or
otherwise entered the body, seek medical attention
immediately!
• Keep new and used batteries and an open battery
compartment away from children.
• Observe the storage and operating conditions (see
Technical data).
Intended use
Only use the device for air quality (CO
2
level), indoor
temperature and humidity measurements within the measuring
range specified in the technical data. Observe and comply with
the technical data.
Any use other than the intended use is regarded as misuse.
Reasonably foreseeable misuse
Do not use the device in potentially explosive atmospheres, for
measurements in liquids or at live parts.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Personnel qualification
People who use this device must:
• have read and understood the instructions, especially the
Safety chapter.
Residual risks
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Notice
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Notice
Do not use abrasive cleaners or solvents to clean the
device.
Information about the device
Device description
The CO₂air quality monitor is a mains-powered measuring
device with a comprehensive range of measurement options.
It comes with the following functional properties and equipment
features:
• PASmeasurement of carbon dioxide concentrations in the
room air
• Simultaneous indication of CO₂values, room temperature,
humidity level, date, weekday and time
• Minimum and maximum value function for CO₂, air
temperature and humidity
• Carbon dioxide alarm function with acoustic alarm for a
freely definable limit value
• Additional CO₂indicator icon (feel-good indication)
• Automatic baseline calibration
• Manual calibration
Automatic baseline calibration
The expected CO
2
fresh air value is about400ppm (0.04%vol)
nowadays. The device assumes this value to be the lowest limit
value (baseline).
A special algorithm continuously monitors the lowest CO
2
value
detected by the sensor over a pre-configured time interval for
several days. The algorithm slowly corrects any long-term drift
detected compared to the expected CO
2
fresh air value of
400ppm (or 0.04%vol).
If the device is used normally indoors, the carbon dioxide
content will always drop almost to the low level of the outdoor
air in the course of a week.
By recording the values over a period of 8days and then
comparing the lowest value to the 400pm point, the device
determines whether or not it needs to adjust the zero point.
The algorithm makes use of the fact that the CO
2
content in
buildings and rooms regularly stabilizes at a minimum for a
certain period of time when they are not occupied. In rooms that
are continuously occupied or where there is a constantly
increased CO
2
concentration (e.g. in greenhouses), the principle
of automatic balancing therefore does not work.
Produktspecifikationer
Varumärke: | Trotec |
Kategori: | Inte kategoriserad |
Modell: | BZ26 |
Enhetsplacering: | Vrijstaand |
Typ av operation: | Draaiknop |
Färg på produkten: | Roestvrijstaal |
Dörrgångjärn: | Neer |
Inbyggd display: | Nee |
Grill: | Ja |
Wi-Fi-kontroll: | Nee |
Konvektionsmatlagning: | Ja |
Rotisserie: | Ja |
Husmaterial: | Roestvrijstaal |
Total inomhuskapacitet (ugnar): | 22.8 l |
Antal ugnar: | 1 |
Kontrollposition: | Voorkant |
LED-indikatorer: | Ja |
På / Av knapp: | Ja |
Material genom: | Glas |
Energiförbrukning (konventionell): | - kWu |
Energiförbrukning (tvungen konvektion): | - kWu |
Att laga: | Ja |
Ugnsstorlek: | Klein |
Typ av ugn: | Elektrische oven |
Total ugnseffekt: | 1500 W |
Ugn med nettokapacitet: | 12.6 l |
Skriv timer: | Mechanisch |
Antal hyllor: | 3 schappen |
Antihalkfötter: | Ja |
Pizza funktion: | Ja |
Snabb värme: | Ja |
Antal rutnät: | 1 |
Materialbricka: | Roestvrijstaal |
Uppvärmning av hela grillytan: | Ja |
Timerns varaktighet: | 60 min |
Behöver du hjälp?
Om du behöver hjälp med Trotec BZ26 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Trotec Manualer
8 Oktober 2024
4 Oktober 2024
29 September 2024
27 September 2024
24 September 2024
23 September 2024
23 September 2024
22 September 2024
16 September 2024
16 September 2024
Inte kategoriserad Manualer
- Varytec
- Eissound
- Khind
- Somfy
- GoldenEar Technology
- Xplora
- Technical Pro
- MyAVR
- Cropico
- Hamron
- Auriol
- Team
- Dupla
- Noris
- Stiga
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025