Uni-T UT161D Bruksanvisning
Uni-T
Multimeter
UT161D
Läs gratis den bruksanvisning för Uni-T UT161D (6 sidor) i kategorin Multimeter. Guiden har ansetts hjälpsam av 15 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 8 recensioner. Har du en fråga om Uni-T UT161D eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/6

United Kingdom •
www.clasohlson.co.uk
English
Ver. 20210530
Digital Multimeter with USB Interface – Quick Start Guide
Description
1. NCV (Non-Contact Voltage) detector
2. LCD display
3. [ Hz% / USB ] buon
• Short-press to select frequency measurement.
• Short-press to select Duty Cyclemeasurement.
4. [ Range ] buon
• Short-press to change the measurement range.
The buzzer will sound.
• Long-press to return to Autorange (automac measuring
range selecon mode).
5. [ SELECT ] buon
6. Funcon selector switch
7. Test lead input terminals
8. [ REL / USB ] buon▲
• Short-press to enter the relave value
measurement mode.
• Short-press to exit the relave value measurement mode.
• Long-press to acvate or deacvate the RS232/USB funcon.
The sleep funcon is deacvated when the RS232/USB
funcon is acvated and disappears from the display.
9. [ PEAK/ MAX MIN ] buon
• Short-press to toggle between max and min
measured values.
• Long-press to return to normal display mode.
10. [ HOLD ] buon and backlight switch
• Short-press to save a reading (data hold funcon),
short-press once more to delete the reading.
• Long-press to acvate the display backlight for 10 seconds.
Instructions for use
• Warning: Consult a qualied electrician before using
the instrument if you are at all unsure about its usage.
• Always ensure that the correct funcon and range is selected.
If in doubt about the correct range, start with the highest and
work downwards.
• When measuring voltage always ensure that the instrument is
switched to the correct funcon range and not set to the
current, resistance or diode test range.
Always ensure that you use the correct test lead socket for the
type of measurement to be made.
• Make sure that the object to be measured is not “live”, i.e.
conducng any current before connecng test leads in series
with it (such as when measuring current).
• Make sure that the test leads are in good condion with no
damage to the insulaon.
Measuring voltage
Measuring DC voltage
DC and AC current measurement
Art.no 36-8255 Model UT161D
Note: This is a quick start guide. A full instrucon manual in
English can be downloaded from www.clasohlson.se
Please read the enre instrucon manual before using the
product and then save it for future reference. We reserve the right
for any errors in text or images and any necessary changes made
to technical data. If you have any quesons concerning technical
problems please contact our Customer Services.
Safety instructions
• This measuring instrument is designed for indoor use.
• Do not use this instrument if it or the test leads appear to be
damaged, or if you suspect that the instrument might not work
properly.
• Make sure that your ngers are behind the nger guards when
using the test leads.
• Make sure that the power supply to the circuit being
measured is turned o before taking any measurements.
Even low currents can be dangerous!
• To avoid shocks you need to be careful when you work with
voltage higher then 60VDC or 30VAC RMS.
Voltages higher than this pose a risk of severe electric shocks.
• Set the rotary selector switch to the correct range and funcon
before starng to take readings. The measurement range must
not be changed during a measurement.
• This instrument is protected by fuses, but they will not protect
the instrument from all kinds of misuse.
Display symbols
The data hold funcon is acvated.
The sleep mode is acvated.
Indicates a negave reading
Indicator for AC measurement.
Indicator for DC measurement.
The Autorange mode is acvated
(the meter automacally selects the range).
The reading is too high for this measuring range.
Indicator for the diode test.
The connuity buzzer is acvated.
Maximum and minimum reading.
Data transmission in progress (USB).
Low baery warning – replace the baery.
REL is acvated, the stored value
minus the present value is displayed.
Resistance: Ω ohms, kΩ (kiloohms),
MΩ (megaohms).
Voltage: mV (millivolts), V (volts).
Current: μA (microamperea),
mA (milliamperes), A (amperes).
Capacitance: nF (nanofarads),
μF (microfarads), mF(millifarads).
Frequency: Hz (hertz), kHz (kilohertz),
MHz(megahertz).
U S B
A
U S B
RL
RL
2
4
5
6
3
7
8
9
10
1
1. Connect the black test lead
to
and the red test
lead to .
2. Set the funcon selector
to for DC voltage
measurement.
3. If you wish to change
the measurement range
manually, short-press
[ Range ] the required
number of mes.
4. Connect the test leads
across the source or load to
be measured.
1. Connect the black test
lead to and the red
test lead to (for
measuring 0–600 mA) or to
(for measuring
between 600mA and 10A).
2. Set the funcon selector to
the desired measuring range
, . or
3. The default measuring
funcon of the mulmeter
is DC, short-press
[ SELECT ] to change to AC
measurement.
4. Connect the test leads in
Hold (save the reading)
1. Short-press [ Hold ] to save the present reading.
2. The buzzer sounds once and appears on the display when
Hold is acvated.
3. The reading is deleted if you press the buon once again.
Backlight
Long-press [Hold/Light] to turn on the backlight. The light will turn
o automacally aer 10 seconds.
Measuring AC voltage
1. Connect the black test lead to
and the red test lead to
.
2. Set the funcon selector to for AC voltage measurement.
3. If you wish to change the measurement range manually,
short-press [ Range ] the required number of mes.
4. Connect the test leads across the source or load to be
measured.
series with the load and source of the current to be measured.
5. When measuring current between 600mA and 20A (without a
fuse) follow the method above but connect the red test lead to
20A max.
Measuring resistance
1. Connect the black test lead
to
and the red test
lead to .
2. Set the funcon selector
switch to resistance
measurement .
3. Connect the test leads to
the circuit to be tested.
Produktspecifikationer
| Varumärke: | Uni-T |
| Kategori: | Multimeter |
| Modell: | UT161D |
Behöver du hjälp?
Om du behöver hjälp med Uni-T UT161D ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Uni-T Manualer
10 September 2025
10 September 2025
10 September 2025
6 Augusti 2025
19 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
18 Juni 2025
16 Juni 2025
Multimeter Manualer
- Högert
- Rigol
- Greenlee
- Hager
- Sanwa
- Velleman
- Clas Ohlson
- Noyafa
- Digitus
- Chauvin Arnoux
- Kewtech
- Caltek
- Projecta
- PCE Instruments
- Elma
Nyaste Multimeter Manualer
20 Oktober 2025
13 Oktober 2025
7 Oktober 2025
7 Oktober 2025
26 September 2025
26 September 2025
26 September 2025
26 September 2025
26 September 2025
26 September 2025