Uni-T UT22B-EU Bruksanvisning
                    Uni-T
                    
                    Inte kategoriserad
                    
                    UT22B-EU
                
                                
    Läs gratis den bruksanvisning för Uni-T UT22B-EU (5 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 27 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 14 recensioner. Har du en fråga om Uni-T UT22B-EU eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/5
                    
                    
                    
English
UNITED KINGDOM • 
Customer Service  Returns Address e-mail: customerservice@clasohlson.co.uk  Clas Ohlson Ltd, The Archway, 7-9 West Street, Reading, Berkshire, RG1 1TT
Ver. 20201126
UNI-T Voltage Tester
Art.no  36-8124  Model  UT22B-EU
Please read theentire instruction manual before using theproduct and then 
save it for future reference. We reserve theright for any errors in text or images 
and any necessary changes made to technicaldata. If you have any questions 
concerning technical problems please contact our Customer Services.
Safety
First read theentire instruction manual and make sure that you have understood 
all theinformation regarding safety and maintenance in order to be able to 
use thevoltage tester in asafeway. 
Warning:
•  To avoid electric shocks, pay special attention when themeasured voltage 
exceeds thesafe working voltage threshold (36V).
•  Do not measure voltages over 400V. The Hazardous Voltage indicator 
will turn on when themeasured voltage exceeds 50V and flash when 
thevoltage exceeds thepotentially lethal voltage threshold of 400V.
•  The voltage tester should not be connected to avoltage source for more 
than 5 seconds at atime.
•  The function of thevoltage tester should be checked on aknown voltage 
source before measuring is commenced.
•  Only grip thetest probes by thehandles. Never touch theelectrodes (tips) 
of thetext probes.
•  The voltage tester must only be used on circuits within thespecified 
measuring range (400V).
•  Do not use thevoltage tester if it is in any way damaged or malfunctioning.
•  Do not use thevoltage tester in awet or humid environment. Accurate 
readings can only be guaranteed within thetemperature and humidity 
ranges specified in the  sectionbelow.Specifications
•  Safety can no longer be guaranteed if thevoltage tester does not display 
reliable readings.
•  When using thevoltage tester, only touch thegripping surfaces of thetest 
probes, never touch themetaltips.
Symbols
Product description
The UT22B-EU is anautomatic voltage tester capable of 
testing AC/DC voltages from 12V to 400V. It is designed 
to be suitable for use by professional electricians and 
homeownersalike. Typical applications of thevoltage 
tester include testing thevoltage of acar battery 
(direct current) and testing thevoltage of awall socket 
(alternating current).
1.  Negative test electrode (−)
2.  Positive test electrode (+)
3.  High and hazardous voltage indicator (> 50 V)
4.  Voltage level indicators
5.  AC/DC voltage indicators
If thepositive indicator comes on, thepositive test probe (+) is connected to 
thepositive terminal of theobject undertest.
If thenegative indicator comes on, thenegative test probe (−) is connected to 
thenegative terminal of theobject undertest.
Note: If thevoltage under test is less than 10V, thetester may not detectit.
Care and maintenance
•  In theevent of abnormal operation or malfunction, stop using thevoltage 
tester immediately and contact your retailer.
•  Repairs must only be carried out by aqualified electrician.
•  Clean thevoltage tester by wiping it with aclean, drycloth.
•  Store thevoltage tester in adry and clean place out of children’sreach.
•  Make sure that thevoltage tester is dry before usingit.
Responsible disposal
This symbol indicates that theproduct should not be disposed 
of with general householdwaste. This applies throughout 
theentireEU. In order to prevent any harm to theenvironment 
or health hazards caused by incorrect waste disposal, 
theproduct must be handed in for recycling so that thematerial 
can be disposed of in aresponsible manner. When recycling 
your product, take it to your local collection facility or contact 
theplace of purchase. They will ensure that theproduct is disposed of in 
anenvironmentally sound manner.
Specifications
Measuring range  12−400 V AC/DC
Frequency range AC  0−60 Hz
Polarity detection  Automatic
Standard compliance  EN 61326-1:2013, EN 61326-2-2:2013,  
  EN 61243-3:2014
Measurement category  CAT III 400 V
Impedance (internal resistance)  17kΩ@ELVa.c (<50 V AC = 17kΩ)
Recovery time  <5 s
Overvoltage protection  > 400 V AC/DC
IP rating  IP54
Indication steps  ± 12, 24, 50, 120, 230, 400 V AC/DC
Polarity indicators   DC positive: (+) Plus sign lit,  
  DC negative: (−) Minus sign lit,  
  AC: (+/−) Both theAC and DC voltage  
  indicators lit
Operating temperature / humidity  −15 to 45 °C, RH < 85 %
Storage temperature  −20 to 60 °C
Dimensions  265x42x27mm
Weight  136 g
Warning, potential hazard. Follow theinstructions in this instruction 
manual. 
The voltage tester should not be disposed of in your bin as 
householdwaste. Thevoltage tester should be regarded as 
waste electrical and electronic equipment and taken to your local 
household waste recycling centre for disposal in accordance with 
local regulations.  
If you are unsure how to proceed, contact your local council.
The voltage tester complies with European Union standards.
1 2
3
4
5
Instructions for use
The function of thevoltage tester should be checked on aknown voltage 
source before measuring is commenced.
•  To test theDC voltage measurement function: use abattery with aknown 
voltage, such as acar battery.
•  To test theAC voltage measurement function: use aknown voltage, such 
as a230V wall socket.
Note: Do not use thevoltage tester if it is not functioning properly.
Measuring AC voltage
Touch thetips of thetest probes against theobject undertest.
For AC voltages over 12 V both thepositive (plus sign) and negative (minus 
sign) indicators willlight. The AC/DC voltage indicators come on in stages 
depending on themagnitude of thevoltage.
Measuring DC voltage
Touch thetips of thetest probes against theobject undertest.
For DC voltage over 12 V either thepositive or negative indicator will turn on 
depending on thepolarity. The AC/DC voltage indicators come on in stages 
depending on themagnitude of thevoltage.
Features
•  Measures alternating current and direct current from  
12 V to 400V.
•  Automatic identification of AC/DC voltage
•  Automatic identification of DC voltage polarity
•  Hazardous voltage indicator
•  Complies with thefollowing standards: RoHS, CE, and  
CAT III 400 V
•  Has aningress protection rating ofIP54. Harmful amounts 
of dust and water can not enter thevoltage tester and 
cause insulation faults.
Produktspecifikationer
| Varumärke: | Uni-T | 
| Kategori: | Inte kategoriserad | 
| Modell: | UT22B-EU | 
| Färg på produkten: | Zwart | 
| Sladdlängd: | 40 m | 
| Kompatibla operativsystem: | Win 98SE, ME, 2000, XP, Vista\nMac OS 9.x + | 
| Anslutning 1: | USB 1.1 | 
| Anslutning 2: | Cat.5e | 
Behöver du hjälp?
Om du behöver hjälp med Uni-T UT22B-EU ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Uni-T Manualer
                        
                         20 September 2024
                        
                    
                                                            
                        
                         3 September 2024
                        
                    
                                                            
                        
                         28 Augusti 2024
                        
                    
                                                            
                        
                         27 Augusti 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Buffalo
 - Analogis
 - Estella
 - Gami
 - Manitowoc
 - Vocopro
 - Wehkamp
 - Nous
 - Tork
 - IClever
 - Flame
 - Wago
 - Reltech
 - Alto
 - SolarEdge
 
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025