Läs gratis den bruksanvisning för Ventus WA110 (1 sidor) i kategorin Temperaturregulator. Guiden har ansetts hjälpsam av 21 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 11 recensioner. Har du en fråga om Ventus WA110 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/1

DIGITAL THERMOMETER WA 110
SPECIFICATIONS:
* 2-piece display
* C / F option
* Min / max memory
* Indoor / outdoor temperature
* Reset function.
* Frost alarm (-1 deg.C ~ 4 deg.C) (adjustable)
* Battery: 1 AAA
* Temperature scale: Indoor: -20 ~ 70 deg.C deg.C Outdoor: -50 ~ 70 deg.C deg.C
* Tolerance: + / -1 gr.C. + / -2 Gr.F
Functions :
MIN / MAX: shows the lowest and the highest temperature when the button is pressed. Hold the button for 3
seconds and min / max reset.
ALE: Setting the alarm
C / F: switch between Celsius and Fahrenheit and setting the temperature alarm range.
RESET: Reset
APPLICATION:
When batteries are installed, the LCD display shows all numbers and letters, and the alarm will sound 4
times. After 5 seconds the temperature will be displayed. Frost alarm is turned off and the temperature is
given in Celsius.
VIEWING THE MIN / MAX TEMPERATURE:
Press MIN / MAX to display the highest temperature indoors and outdoors. Press the button again and the
display show the lowest temperature indoors and outdoors. Press again and the display returns to the here
and now temperature. Do you wish to delete min / max temperatures hold button for 3 seconds.
ALARM SET: (only outdoors)
Press ALE to activate the alarm function. (ALE ON appears in the display) Press again and the alarm
function is turned off. (ALE OFF displayed) If the button is not affected in 2 seconds the display returns to the
here and now temperature. Hold the button for 3 seconds and you can now set the alarm for outdoor
temperature. Use the C / F to set the desired temperature. When the desired temperature is set and the
temperature in the top line is higher than the bottom line and the outdoor temperature falls within the preset
temperature alarm will go off. Conversely, if the temperature in the bottom line is higher than the top line and
the outdoor temperature reaches the preset temperature alarm will go off.
Press ALE to return for inside / outside door temperature. When the alarm goes off, it sounds for 5 seconds
every minute until the temperature falls within the preset tolerance or press the EFA button.
Produktspecifikationer
Varumärke: | Ventus |
Kategori: | Temperaturregulator |
Modell: | WA110 |
Behöver du hjälp?
Om du behöver hjälp med Ventus WA110 ställ en fråga nedan och andra användare kommer att svara dig
Temperaturregulator Ventus Manualer
1 September 2024
Temperaturregulator Manualer
- Davis
- Ygnis
- Honeywell
- Carel
- Inkbird
- Kathrein
- Berker
- Cocraft
- ACV
- Fluke
- Emko
- Opticlimate
- Wachendorff
- Hager
- Astralpool
Nyaste Temperaturregulator Manualer
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
28 December 2024
17 December 2024