Viking VBI7360WLSS Bruksanvisning
Läs nedan 📖 manual på svenska för Viking VBI7360WLSS (24 sidor) i kategorin kylskåp. Denna guide var användbar för 5 personer och betygsatt med 4.5 stjärnor i genomsnitt av 3 användare
Sida 1/24

Installation
Guide
Integrated Refrigerator / Freezer
7 SERIES
VBI7360 / CVBI7360
FBI7360 / CFBI7360
MVBI7360 / CMVBI7360
MFBI7360 / CMFBI7360

2
Table of Contents
Warnings and Important Information _______________________________________________________ 3
Professional Bottom-Freezer
Dimensions _______________________________________________________________________ 5
Speci cations ______________________________________________________________________ 6
Cutout Dimensions__________________________________________________________________ 7
Anti-Tip Dimensions (36”) ____________________________________________________________ 8
General Information
Electrical Requirements ______________________________________________________________ 9
Water Requirements ________________________________________________________________ 10
Unpacking & Moving ___________________________________________________________________ 11
Installation
Door/Drawer Panel Adjustments ______________________________________________________ 11
Custom Front Panel Dimensions ______________________________________________________ 12
Custom Front Panel Install ___________________________________________________________ 13
Water Line Installation ______________________________________________________________ 14
Leveling Unit ______________________________________________________________________ 16
Kickplate Installation _______________________________________________________________ 16
Flush Mount Side Trim ______________________________________________________________ 17
Door Stop Adjustment ______________________________________________________________ 18
System Speci cations and Data _______________________________________________________ 19
Performance Checklist __________________________________________________________________ 20
Control Panels _________________________________________________________________________ 20
Service & Registration __________________________________________________________________ 21

33
IMPORTANT – Please Read and Follow!
• Make sure that incoming voltage is the
same as unit rating. An electric rating
plate specifying voltage, frequency,
wattage, amperage, and phase is
attached to the product.
• To reduce the risk of re, electrical shock,
or injury to persons, installation work
and electrical wiring must be done by
a quali ed technician in accordance
with all applicable codes and standards,
including re-rated construction.
• The installer should leave these
instructions with the consumer who
should retain them for local inspector’s
use and for future reference.
For additional information or installation
videos, visit our website at www.
vikingrange.com in the US or brigade.ca in
Canada.
DANGER
WARNING
You will be killed or seriously injured if you
don't follow instructions.
You can be killed or seriously injured if you
don't follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
Your safety and the safety of others is very
important.
We have provided many important safety
messages in this manual and on your appliance.
ALWAYS read and obey all safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be preceded by the
safety alert symbol and the word “DANGER” or
“WARNING.” These words mean:
It is your responsibility to:
• comply with installation speci cations and dimensions.
• properly install unit.
• remove any moldings or decorative panels that prevent the unit from being serviced.
• make sure that you have these materials (not provided with your unit), which are necessary
for proper installation:
• 1/4” (6 mm) copper tubing with shuto valve
• 1– Saddle valve (do not use self-piercing feature of the valve)
• assure that oor will support unit, door panels and contents (approximately
1200 pounds [540 kg]).
• provide a properly grounded electrical outlet.
• assure that location will permit appliance doors to open 90º minimum.

4
WARNING
TIP OVER HAZARD
Appliance is top heavy and tips
easily when not completely
installed. Keep doors closed until
appliance is completely installed
and secured per installation instructions.
Use two or more people to move and install
appliance. Failure to do so can result in death or
serious injury.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power or turn
power disconnect switch to
OFF position before removing
top grille. Failure to do so can result in death or
electrical shock.
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any signi cant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not
installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose- tting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
Power On/O Switch
Your unit is shipped with the power switch on. When rst plugged in, the
display will ash. Push any button to initiate display.
The power on/o switch is located to the left of the center behind the
access panel. It is used to turn the power o when cleaning or servicing
the refrigerator.
To turn power o , remove the access panel. Press the power on/o switch
to the o position.
To turn power on, press power on/o switch to the on position. Replace
access panel.
B
access panel
IMPORTANT – Please Read and Follow!

5
5
50-1/2”
(128.3 cm)
12-1/8”
(30.8 cm)
17-1/16”
(43.3 cm)
24-5/8”
(62.5 cm)
83-15/16”
(213.2 cm)
36”
(91.4 cm)
22-1/2”
(57.2 cm)
4-1/16” (10.3 cm)
A
Dimensions (Integrated Bottom-Freezer)
Dimension A
VBI7360/CVBI7360
FBI7360/CFBI7360 27-3/8" (69.5 cm)
MVBI 360/CMVBI 3607 7 27" (68.5 cm)

6
6
Speci cations (Integrated Bottom-Freezer)
36” Integrated Refrigerator/Freezer
Description VBI7360 / CVBI7360 MVBI 360 / CMVBI 3607 7
Overall width 36" (91.4 cm)
Overall height (from bottom) 83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max
Overall depth from rear To front edge kickplate: 22-1/2” (57.2 cm)
To front of door panel: 24-5/8” (62.5 cm)
To front of handle endcap:
27-3/8" (69.5 cm)
To front of handle endcap:
27" (68.5 cm)
Cutout width 36" (91.4 cm)
Cutout height 84-3/16" (213.8 cm) min to 85-3/16" (216.3 cm) max
Cutout depth 25” (63.5 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi;
maximum 120 psi
Overall interior dimensions
Refrigerator
Freezer
Total capacity
13.6 cu. ft. (385.8 liters)
6.35 cu. ft. (180.1 liters)
19.95 cu. ft. (565.9 liters)
Approximate shipping weight 565 lbs. (254.3 kg)
36” Integrated Refrigerator/Freezer w/Custom Panels
Description FBI7360 / CFBI7360
Overall width 36" (91.4 cm)
Overall height (from bottom) 83-15/16" (213.2 cm) min to 84-3/4" (215.7 cm) max
Overall depth from rear To front edge kickplate: 22-1/2” (57.2 cm)
To front of door panel: 24-5/8” (62.5 cm)
To front of handle endcap: 27-3/8" (69.5 cm)
Cutout width 36" (91.4 cm)
Cutout height 84-3/16" (213.8 cm) min to 85-3/16" (216.3 cm) max
Cutout depth 25” (63.5 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi;
maximum 120 psi
Overall interior dimensions
Refrigerator
Freezer
Total capacity
13.6 cu. ft. (385.8 liters)
6.35 cu. ft. (180.1 liters)
19.95 cu. ft. (565.9 liters)
Approximate shipping weight 565 lbs. (254.3 kg)

8
8
Anti-Tip Dimensions (Bottom-Freezer)
WARNING
TIP OVER HAZARD
Appliance is top heavy and tips easily when not
completely installed. To avoid avoid a hazard due to
instability of the appliance, it must be installed according
to the instructions including the anti-tip bracket
C
C
Cabinet
Rear
Floor A
Cabinet
Opening
Dimension A = Cabinet opening minus the refrigerator height + 1-1/4" (3.2 cm)
Anti-tip Bracket
There are 12 hole locations on the anti-tip
bracket. Of those 12, at least 4 places must
be used.
NOTE: Number of fasteners must be
suitable for load in order to prevent tipping.

9
9
General Information
Area Requirements
Verify the following:
• Unit can t into residence and can be
moved around corners and through
doorways.
• Floors can support unit’s weight plus
food weight (approximately 1200
pounds [540 kg] per unit).
• Floors underneath refrigerator are level
with surrounding nished oor.
• Remove anything attached to rear or side
walls that can obstruct unit installation.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
• Water line is in correct location.
•
DO NOT install a refrigeration unit near
a heat source, nor in a location where the
surrounding temperature will fall below
60º F (16º C).
Electrical Requirements
It is the customer’s responsibility to:
• Contact a quali ed electrical installer.
• Assure that the electrical installation
is adequate and in conformance with
the National Electrical Code, ANSI/NFPA
70-latest edition or Canadian Electrical
Code C22.1-1998 and C22.2 No. 0-M91
(or latest edition), and all local codes and
ordinances.
A 115 volt, 60-Hz, 15 amp, fused, electrical
supply is required. It is required that a
separate circuit serving only this appliance
be provided. This appliance is equipped
with a power supply cord having a 3-prong
grounding plug. To minimize possible
shock hazard, the cord must be plugged
into a mating 3-prong, grounding-type wall
receptacle.
If the supply cord is damaged, it must be
replaced by the manufacutrer or it service
agent or a quali ed service technician in
order to avoid a hazard.
DO NOT use an extension cord or
ungrounded (two-prong) adapter.
If codes permit a separate grounding wire
to be used, it is recommended that a quali ed
electrician determine that the grounding path is
adequate.
DO NOT ground to a gas line. Check with a
quali ed electrician if you are not sure if the
appliance is properly grounded. DO NOT
have a fuse in the neutral or grounding circuit.
Anti-Tip Requirements
The anti-tip device should be installed prior to
moving the unit into place.
Use only 1/4” (6 mm) copper tubing for
water line. DO NOT install copper tubing
in area where temperatures drop below
35º F (1.7º C). Before attaching copper
tubing to the unit, ush at least 2 quarts
(1.9 L) of water through the copper tubing
and into a bucket to remove any particles
in the water line.
WARNING
To avoid serious illness or death, connect to a
potable water supply only. DO NOT use unit
where water is microbiologically unsafe or of
unknown quality, without adequate disinfection
before or after the system. Systems certi ed
for cyst reduction may be used on disinfected
water that may contain lterable cysts. The
contaminants or other substances removed or
reduced by this water treatment system are not
necessarily in your water.
CAUTION
Be sure to have a replacement cartridge
available when lter change is required.
• If water ltration system has been allowed to
freeze, replace lter cartridge.
• If system has not been used in several months,
and water has an unpleasant taste or odor, ush
system by dispensing 2-3 glasses of water. If
unpleasant taste or odor persists, change lter
cartridge.
• Make sure to tighten the water lter to its home
position. An improper tightened water lter
will not allow the water to ow.
Water Supply Requirements

10
10
General Information
• Viking Range, LLC is not responsible
for property damage due to improper
installation or water connection.
• Connect 1/4” (6 mm) exible copper tubing to
household plumbing in compliance with local
codes and ordinances.
• Length of copper tubing must reach from water
supply connection to the unit connection with an
additional length to facilitate moving the unit out
of enclosure for cleaning or service. Tubing should
be soft instead of rigid and ends should be free of
burrs.
• Copper tubing route must be above 35º F
(1.7º C) to prevent water line from freezing.
• DO NOT use plastic water lines from
the household plumbing to the water
inlet valve connection on the refrigeration
unit.
• DO NOT use the self-piercing feature of
a saddle valve. The hole made by the
piercing lance is too small for the water
ow rate required by the ice maker.
• If saddle valve is not used, place a separate shut-
o valve in an easily accessible location between
water supply and the unit. DO NOT install shut-o
valve behind the unit.
• The installation of Viking Range, LLC units with
a reverse osmosis system is acceptable as long
as the water pressure remains within the
allowable PSI as stated below. It is important
to note that with many reverse osmosis systems,
the pressure starts o high, but then it decreases as
the water level of the reverse osmosis storage area
drops. This must be considered when checking the
water pressure coming into the unit.
• Connect a vertical or horizontal 1/2” (1.3 cm) to
1-1/4” (3.2 cm) COLD water line near water area.
• Run water line through the oor, back, or side wall
in area shown on page 7. Connect to water supply
coming from back of unit on the left side.
• Water pressure must be greater than 20 psi and
less than 120 psi on non-dispenser units and
greater than 35 psi and less than 120 psi on
dispenser units.
Area Requirements
• Most of the unit’s weight is at the top.
Extra care is needed when moving the unit to
prevent tipping.
•
DO NOT remove protective lm until unit is in
operating position.
• All four leveling legs must contact the oor to
support and stabilize the full weight.
• DO NOT drop unit.
• Remove exterior shipping materials prior to
moving unit into home, except door latching
device.
• Use two or more people to move and install unit.
Failure to follow this instruction can result in back
or other injury.
• To avoid personal injury, wear gloves when
performing any installation procedure and
wear eye protection when cutting metal
straps.
Tip Over Hazard
Appliance is top heavy and tips easily when not
completely installed. Keep doors closed until
appliance is completely installed and secured per
installation instructions. Use two or more people to
move and install appliance. Failure to do so can result
in death or serious injury.
Unpacking Unit
1. Remove top and bottom strap.
2. Remove top cap.
3. Cut carton rear approximately 1/4” (0.6 cm) to
1” (2.5 cm) from right corner with a utility knife
extended 1/4” (0.6 cm).
4. Remove carton and exterior packaging. Save
cardboard shipping material to protect oor
surface when installing unit. Remove anti-tip
board, kickplate and side trim from rear of unit.

11
11
Moving Unit
Remove shipping brackets from skid by removing four
bolts (two on each side) with a 1/2” (1.3 cm) deep-well
socket wench and a pair of pliers. Note: Tilting unit is not
required to remove shipping brackets.
1
A
Slip appliance dolly between unit and skid.
Remove unit from skid. Note: Use excess packaging
to protect decorative trim; also, verify that
leveling legs are up (0” adjustment).
Door / Drawer Panel Adjustments
On the side of each panel, at the top and bottom there is a vertical slot with a cam spacer for front to back
adjustments. In the center, there is a horizontal adjustment for up and down. All hardware needs to be
loosened before adjusting.
F
Vertical slot for front to back
adjustment
Vertical slot for front to
back adjustment
Horizontal slot for up and
down adjustment
Produktspecifikationer
Varumärke: | Viking |
Kategori: | kylskåp |
Modell: | VBI7360WLSS |
Behöver du hjälp?
Om du behöver hjälp med Viking VBI7360WLSS ställ en fråga nedan och andra användare kommer att svara dig
kylskåp Viking Manualer

2 April 2025

1 April 2025

10 December 2024

10 December 2024

10 Oktober 2024

8 Oktober 2024

5 Oktober 2024

27 September 2024

15 September 2024

13 September 2024
kylskåp Manualer
- kylskåp APW Wyott
- kylskåp New Pol
- kylskåp WhiteLine
- kylskåp Trisa
- kylskåp Insignia
- kylskåp Fagor
- kylskåp Daikin
- kylskåp Brass Monkey
- kylskåp Svan
- kylskåp Gourmetmaxx
- kylskåp Delfield
- kylskåp Tricity Bendix
- kylskåp Castor
- kylskåp Bartscher
- kylskåp Zanussi
Nyaste kylskåp Manualer

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

8 April 2025

8 April 2025

8 April 2025