Läs gratis den bruksanvisning för ZKTeco AQD-H35 (1 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 23 personer och har ett genomsnittsbetyg på 4.1 stjärnor baserat på 8 recensioner. Har du en fråga om ZKTeco AQD-H35 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/1

User Manual
Air Quality DetectorQD-H35 A
Version: 1.0
Display method: Common Screen display
Atmospheric preure: 86Kpa to 106Kpa ss
Detection method for CO2: Infrared (NDIR)
Detection method for PM: Laser scattering
Sampling time: 1.5 seconds
Product ze: 90*90*50mm Si
Concentration unit for CO2: PPM
Concentration unit for PM: ug/m3
Power source: Lithium battery with 2000 mAh capacity;
5V DC power charging via micro USB port
Product weight: 200g
Product Description
This product is an air quality monitor that detects Carbon
dioxe (CO2) in real-time monitoring. id
2
Considerations
Please read the instructions carefully before using this
device.
Please let the device work short mins outdoors before
use for most accurate results .
Please keep the manual handy for quick reference and
tubleshooting. ro
Precautions
Avoid covering the air intake areas during use to avoid
inaccurate measurements.
Avoid use of solnts to cleathe product as residual ven
fumes will skew air qu
ality readings.
Avoid water or other liquids near the product to avoid
electrical damage.
Do not allow unauthorized modi catioor repair of this n
product.
Features:
-Common Screen display
-Test variables: Carbon dioxide (CO2)
-Large 2000mAh capacity Lithium battery
-5V Micro USB charging
-Low battery warning
3
Instruions ct
1. Start Up
When you long-press the power bton, the air quality ut
monitor will boot up.
It would auto ash each 5 seconds switching data from
PM1.0, PM2.5, PM10.
4
Product Key Funion Description ct
Figure 1
Figure 2
Figure 3
①
Display reensc
②
Power bton ut
1.
Long press for 3 seconds to turn device on/o ;
2.Single click to switch Celsius and Fahrenheit;
3.Double click to turn on/o Alarm function(when turn on alarm
function, it would beep sound once CO2 value more than 0M)100PP
③
Air hole ofack b
④
Battery cover of back
⑤
Foot pads
⑥
Side air ow holes
⑦USB charng portgi
5
2. About Charging
When low battery icon is displayed, the device needs to be
charged. Insert the included or another compatible micro
USB charging cable into the deve. Attach the other end ic
to a USB DC charger (such as a smart phone charger) that
outputs DC 5V at >=1000mA. Fully charge for at least 2-3
hours before use. Avoid charging with a USB computer
port which only outputs 500mA.
3.Parameters
CO2 technical indicators
Measung range: 400 to 5000MSensoror CO2: Infrared ( NDIR) riPP f
Resolution: 1 PPM
Pruct List od
Air Quality monitor x 1
Micro USB charging cable x 1
Product Manual x 1
6
Copyright © 2021 ZKTECO CO., LTD. All Rights Reserved.
Ctra. Fuencarral 44. Edicio 1, Planta 2.
28108 Alcobendas, Madrid. Spain
Phone: +34 916 532 891
Mail: [email protected]
www.zkteco.eu
Produktspecifikationer
| Varumärke: | ZKTeco |
| Kategori: | Inte kategoriserad |
| Modell: | AQD-H35 |
Behöver du hjälp?
Om du behöver hjälp med ZKTeco AQD-H35 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad ZKTeco Manualer
10 Mars 2025
25 September 2024
23 September 2024
4 September 2024
4 September 2024
4 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
Inte kategoriserad Manualer
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025