ZKTeco inBio-160 Bruksanvisning

Läs gratis den bruksanvisning för ZKTeco inBio-160 (4 sidor) i kategorin Tillträdeskontrollsystem. Guiden har ansetts hjälpsam av 7 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 4 recensioner. Har du en fråga om ZKTeco inBio-160 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
1
2
Box Lock Hole
State Indicator
Thread Hole
3.
3.
3.
3.3.Installation
Installation
Installation
InstallationInstallation
Backup Battery
Control Panel
Air Switch
Panel Box Insaid
Get the Panel off the track
Heat
2.
2.
2.
2.2.Components
Components
Components
ComponentsComponents
Thread holes
Screws
1.
1.
1.
1.1.Cautions
Cautions
Cautions
CautionsCautions
4.
4.
4.
4.4.LED Indicators and W
LED Indicators and W
LED Indicators and W
LED Indicators and WLED Indicators and Wire Illustration
ire Illustration
ire Illustration
ire Illustrationire Illustration
i
i
i
iin
n
n
nnB
B
B
BBI
I
I
IIO
O
O
OO I
I
I
IIn
n
n
nns
s
s
sst
t
t
tta
a
a
aal
l
l
lll
l
l
lla
a
a
aat
t
t
tti
i
i
iio
o
o
oon a
n a
n a
n an an
n
n
nnd C
d C
d C
d Cd Co
o
o
oon
n
n
nnn
n
n
nne
e
e
eec
c
c
cct
t
t
tti
i
i
iio
o
o
oon G
n G
n G
n Gn Gu
u
u
uui
i
i
iid
d
d
dde
e
e
ee
16
16
16
1616 0
0
0
0 0
V
V
V
VVe
e
e
eers
rs
rs
rsrsi
i
i
iio
o
o
oon
n
n
nn: 1
: 1
: 1
: 1: 1.
.
.
..3
3
3
33 D
D
D
DDa
a
a
aat
t
t
tte
e
e
ee: J
: J
: J
: J: Ja
a
a
aan
n
n
nn. 2
. 2
. 2
. 2. 20
0
0
001
1
1
114
4
4
4 4
1) Meaning of LED indicators:
LINK indicator (green): Constant light always indicates TCP/IP communication is normal.
ACT indicator (yellow): Flashing indicates data is transmitting through TCP/IP communication.
EXT RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
PC RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
POWER indicator (red): Light always indicates the control panel is power on.
RUN indicator (green): Flashing indicates that system is working normally.
CARD indicator (yellow): Flashing indicates a card is punched on reader.
2) Recommended use of wires
3) The auxiliary input may be connected to infrared body detectors, alarm switches, etc.
4 The auxiliary output may be connected to door bells, alarms, etc.)
5) State Indicators are connected to the panel box, that is power indicator, run status indicator and communication status indicator.
Power Supply
Temper Switch
After th e foll owin g inst alla tion , fix th e pane l to the t rack f irst , and th en ins tall o ther c ompo nent s .
Dissipation Hole
Control Panel
Control Panel
Panel Track
Panel Track
2
2
1
1
3) Install other components
2) Fix the box
1) Get through the thread hole
Interface Wire Specification Network cable Maximum length
Power (A) 18AWG*2PIN / 1.5M
Wiegand (B)
24AWG*6PIN
(6PIN, 8PIN, 10PIN for different
readers)
CAT-5 or above network cable, one
way DC impedance is less than 100Ω
/KM
100M
Electric Lock (C)
18AWG*2PIN+24AWG*2PIN,
18AWG*2PIN for lock connection,
24AWG*2PIN for door sensor
connection.
/ 50M
Button (D) 24AWG*2PIN / 100M
EXT485 (E)
20AWG*2PIN+24AWG*2PIN,
20AWG*2PIN for reader power
supply, 24AWG*2PIN for RS485
communication
CAT-5 or above network cable, one
way DC impedance less than 100Ω
/KM. In wire connection, +12V and
GND of power supply need to be
parallel and use double wires.
Share power with control panel: 100M
Use independence power supply
(connect RS485 signal interface only):
1000M
Ple as e note th e fo llo w ing ca utio ns. Mis -o pe ratio n may le ad to pers onal in ju ry or
equip ment fa ilu re:
1 Do not ene rgiz e th e sys tem be fore in sta lla tio n is com ple te ; ne ver ca rry ou t
in sta lla tio n activ itie s whe n the sy ste m is energiz ed.
2 All perip hera l devic es must b e gro unded .
3 The cond uits of wire s un der re la y must be ma tche d with meta le d co nduits , oth er wire s
4 It is stro ngly re commen ded th at th e le ng th of ex pose d part o f any co nnec tio n cable
should n ot be lo nger th an 4 mm . Pro fe ss iona l cla mpin g to ols may be u sed to a void
unin te ntio nal conta ct of e xpos ed wire s to avoid s hort- circ u it or co mmun icatio n fa ilu re .
5 It is re commen ded th at card read ers an d butto ns be in sta lle d at he ight o f 1.4 m-1 .5 m
above gro und .
6 It is re commen ded to u se th e power s upply for co ntro l pa nel, a nd exte rn al powe r
supply fo r eac h lock .
7 The applia nce sha ll be in sta lle d a nd wire d in accord anc e with natio na l ele ctric al
code and b y qualifie d p ers onnel o nly
Descrip tio n of normal w orkin g sta te :
Connec t the sy ste m to th e power su pply. If th e syste m work s pro perly , th e PO WER
in dic ato r (r ed) is lit consta ntly and th e RUN in dic ato r (g reen ) fla shes.
Valve reg ulated lea d-ac id ba ttery :
Constan t volt ag e ch arge vo ltag e reg ulati on
Cycle use : 14.5V ~14.9V (25 )
Initial cu rren t: less tha n 2.88 A
Stan d by use: 13.6V ~13.8V (25 )
Cap ac ity: 1 2V, 7.2A h /20 hr
Battery Type: L C-R A127R 2T1
Caution :
Do not ch ar ge in a gas tigh t containe r.
Do not sh ort the battery term ina ls.
Do not inc ine rate
Flush wit h water at o nce if co ntact is mad e wit h
elec trolyte (Acid )
Do not attem pt to d isasse mble the battery .
4
6.
6.
6.
6.6.
Lock
Lock
Lock
LockLock Connection
Connection
Connection
ConnectionConnection
5.DIP
5.DIP
5.DIP
5.DIP5.DIP Switch Settings
Switch Settings
Switch Settings
Switch SettingsSwitch Settings
1) 1-6 are used to set the number in communication: Switches control panel RS485 It is adopted binary coding and
address number should not be repeated in the network.
2) Number 7 switch is used to restore factory defaults: Switch it three times within 10 seconds and restart the device,
3) Number 8 switch is used to set terminal resistance in RS485 communication: Switch it toON” status, for adding
4) When electrical lock is connected with access control system, you need to parallel a Fr107 diode (equipped in the
1) The control panel provides lock control output interfaces. For NO lock, it is normal open when power is on, so
2) The control p anel sup ports “dry m ode” and “w et mode” b y using the ju mper. For “wet mo de, sho rt 2- 3 and
3) he standa rd For the Wieg and read er and the i nBIO reader, t power sup ply is 12V /3A. So we d o not recomme nd
little endian, the address number these 6 switches are shown in the figure below. Before setting is set by placing
For example: Set the device number as 39 (39=1+2+4+32), the switches status are 111001, that is set number 1, 2,
COM and NO terminals should be used. For NC lock, it is normal closed when power is on, so COM and NC
package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities.
a terminal resistance of 120 ohm between 485+ and 485-.
then all data will be cleared and the system restored to factory default setting.
the address, please keep the system powered off. Place the corresponding switches to the desired status, and the
3 and 6 switches at “ON.
1
2
4
8
16
32
Restor e Facto ry S ettin gs
RS485 Term i nal Resi st ance
EXTRS485 PCRS485
STATE
PWR
READER2READER1
SWITCH
OUT
ACT
1 2 3 4
O
5 6 7 8
N
terminals should be used.
4-5 termi nals. The con trol panel and th e lock use s eparate po wer supplie s: One is co nnecte d with +12V and
GND of POWE R interf ace (for t he control pa nel), th e other is c onnected wi th V+ and V- of LOCK int erface
(for the lo ck). For d etaile d settings fo r “dry mod e” and “we t mode” , please re fer to the Ins tallation G uide.
The factory de fault is d ry mode.
3
ACT
D
AUX Input1
E
RS485
Reader
State Indicator
D
Exit Button for
Lock 1
B
Reader for
Lock 1
B
Reader for
Lock 1
PC Network
Interface
Dip switch
RS485
Converter
PC
D
AUX Output1
C
Lock 1
A
Lock Power Input
A
Power Input
LINK
EXT
RS4 85
PC
RS4 85
STATE
PWR
REA DER2REA DER1
SWI TCH
OUT
ACT
that the the cont rol pane l If it is nece ssary to d o, so we sug gest using a lock and share a com mon powe r supply.
larger one suc h as 12V/5 A.Not incl uding the p ower res erved, the re are 2A cur rent for the lo ck. For th e common
electri cal lock ( the stan dby c urrent i s 300mA, t he max cur rent is 500mA ), the max imum con nected lock i s 4.
AUX Input 1 connect to the infrared human
body induction, wireless exit button, windows
sensor with dry contact (no voltage).
AUX Input 1 connect way is same.
Note:
Output Electrical Parameters:
Rated Voltage: 12V(DC)
Rated Current: 0.5A
1
2
3
4
7
5
6
5
1
AUX Output 1 connect to alarm, door bell and so on;
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC) MAX Current: 1.25A
Note:
AUX Output 1 connect way is same.
Lock1:
Port (SEN)connect to door sensor single with
dry contact (no voltage);
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC) MAX Current: 2A
Note:
When you select Wet mode,the power is Lock power,
Lock 1 total load don’t more than Lock power Rated
current (2A).
Lock 1 connect way is same.
2
Lock Power Input Electrical Parameters:
Rated Voltage: 36V(DC) Rated Current: 2A
Device Power Input Electrical Parameters:
Rated Voltage: 12V(DC) Rated Current: 2A
3
4
Exit button for Lock1 connect to Exit button with dry contact.(no voltage);
Reader 1 connect to WG Reader;
Port (+12V)Output Electrical Parameters:
Rated Voltage: 12V(DC) Rated Current: 0.5A
Port (BEEP GLED) Output Electrical Parameters:
Rated Voltage: 5V(DC) Raged Current: 0.5mA
SD Card Interface:
Function:
Backup Access
Control Logs
7
6
7
65
8.
8.
8.
8.8.Equipment Communication
Equipment Communication
Equipment Communication
Equipment CommunicationEquipment Communication
+
+
+
-
-
NC
NO
GND
COM
SEN
+
+
-
-
FR1 07
FR1 07
-
PC
PC
LED
1
2
3
4
5
48 5+
485 -
GND
48 5+
48 5+
48 5+
48 5-
48 5-
48 5-
GND
GND
GND
NO Lock
LOCK
LOCK
Enlarged diagram
of lock terminals
NC Lock
Lock Power
Diode
Diode
Jumper
terminal
1. TCP IP Communication/
2. RS485 Communication
The PC software can communicate with the panel according to the communication protocols (RS485 and TCP/IP) for data
exchange and remote management. The communication cable should be as far away from high-voltage lines as possible.
Do not keep the communication cable parallel to power cords or bind them together.
Switch
8# Control Panel
Serial Bus
1# Control Panel
2# Control Panel
48 5
Converter
DIP Switch
8# Control Panel
2# Control Panel
1# Control Panel
1) Internationally accepted RVVP (shielded twisted-pair) wires should be used for communication to effectively avoid inter
- of bus cascade connection. ference. RS485 communication wires should be connected by means
3) One RS485 bus may hold 63 control panels, but it is recommended to connect with less than 32 .access control panels
4) For the inBIO reader connection, if the reader and the control panel use the same power, it is recommended that the wire
5) when the wire is longer than 300 meters, it is necessary to ke ep To enhance the stability of communication number
2)It is recommended that the RS485 bus should be less than 6 00 meters to aid communication stability.
of the two devices to the system. As shown in the figure above, turn number 8 of the DIP switches of the 1 and 8# #
8 switch of the first and the last control panel at “ON” statu s. That adds the RS485 terminal resistance (120 ohm)
should be less than 100 meters. If greater length is required, please use a separate power supply.
EXTRS485 PCRS485
STATE
PWR
READER2READER1
SWITCH
OUT
ACT
EXTRS485 PCRS485
STATE
PWR
READER2READER1
SWITCH
OUT
ACT
EXTRS485 PCRS485
STATE
PWR
READER2READER1
SWITCH
OUT
ACT
EXT
RS485 PCRS485
STATE
PWR
READER2READER1
SWITCH
OUT
ACT
EXTRS485 PCRS485
STATE
PWR
READER2READER1
SWITCH OUT
ACT
EXTRS485 PCRS485
STATE
PWR
READER2READER1
SWITCH
OUT
ACT
1 2 3 4
O
5 6 7 8
N
Insert a screw driver to the rectangular hole in the four co rner of the panel back, push it in until hearing the “click
sound. Then remove the case from the panel. The following is wet m ode” lock connecti on with external power supply.
7.485
7.485
7.485
7.485 7.485
Reader (inBIO Reader)
Reader (inBIO Reader)
Reader (inBIO Reader)
Reader (inBIO Reader)Reader (inBIO Reader) Connection
Connection
Connection
ConnectionConnection
at "ON” status.
The control panel supports inBIO biometric verification reader and Wiegand reader. All inBIO reader operations are executed
For reader 1, 2 (the odd number is for entrance reader, and the even number is for exit reader), the door number is 1. And the
485 address is 1, 2, as in the figure below. For more information, please refer to the software user manual.
from the control panel including storage, verification, etc. Re-register the fingerprints is not required when replacing the reader.
For example, use the FR1200 reader , the standby current is less than 100mA, the max current is less than 120mA, When
separately power supplies, to make sure the steady ope ration.
Besides, a single EXT485 interface can supply maximu m 500m A(1 2V) current . So the entire cuttent consumption
should be less than this max value when the readers share po wer with t he pane l .
In calculation, more than twice of the normalplease use max current of the reader and start current is usually ,
work current, please consider of this situation.
inBIO reader connection: First of all, set the 485 address (device number) of the reader by DIP switch and software.
Attention: DIP switch configuration for FR KR E M RS Software configuration for unnormalized F MA and other fingerprint readers 1200, 500 & - ; 11, 300 .
the device is start, Instantaneous current can reach 2 40 mA. As inBIO reader, consider the starting current is
bigger onnectthrough the EXT485 interface can only c two readers for power supply, . So the power of control
panel connect only For some of the devices with much greater consumption, w e suggest to using the 2 readers.
#
1 R
e
a
der
#2 Read
e
r
PC
STATE
PWR
EXTRS485 PCRS485
SWITCH

Produktspecifikationer

Varumärke: ZKTeco
Kategori: Tillträdeskontrollsystem
Modell: inBio-160

Behöver du hjälp?

Om du behöver hjälp med ZKTeco inBio-160 ställ en fråga nedan och andra användare kommer att svara dig