ZKTeco TF1700 Bruksanvisning


Läs gratis den bruksanvisning för ZKTeco TF1700 (2 sidor) i kategorin Tillträdeskontrollsystem. Guiden har ansetts hjälpsam av 29 personer och har ett genomsnittsbetyg på 4.1 stjärnor baserat på 9 recensioner. Har du en fråga om ZKTeco TF1700 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
Version
Version
Version
VersionVersion1.1 Date
1.1 Date
1.1 Date
1.1 Date1.1 DateSep.
Sep.
Sep.
Sep.Sep.
:
:
:
: : :
:
:
: :
2011
2011
2011
20112011
TF1700InstallationGuide
1.Equipment Installation
2.Structure and Function
3. LockConnection
23
WiringHole
Before t
Before t
Before t
Before tBefore the dev
he dev
he dev
he devhe device is fas
ice is fas
ice is fas
ice is fasice is fastene
tene
tene
tenetened, pleas
d, pleas
d, pleas
d, pleasd, please
e
e
ee
stick th
stick th
stick th
stick thstick the pape
e pape
e pape
e papee paper to the pla
r to the pla
r to the pla
r to the plar to the place whe
ce whe
ce whe
ce whece where you
re you
re you
re youre you
want to in
want to in
want to in
want to inwant to instal
stal
stal
stalstall it, then m
l it, then m
l it, then m
l it, then ml it, then make ho
ake ho
ake ho
ake hoake holes and
les and
les and
les andles and
lay cabl
lay cabl
lay cabl
lay cabllay cables acc
es acc
es acc
es acces according t
ording t
ording t
ording tording to the mo
o the mo
o the mo
o the moo the mounting
unting
unting
untingunting
paper.
paper.
paper.
paper. paper.
TF1700 Mounting Paper
(only for your reference)
Fixing Hole
Fixing Hole
Fixing Hole
10
11
12
13
(1) Postthemountingtemplateonthe
wallDrilltheholesaccordingto.
themarksonthe templateholes (
(2) Removethescrewsonthe
(3) Takeawaythebackplate.
(5) Tighten the screws on the bottom,
plate on the wall accordingtothe
(4) Fixthe plastic pad and theback
forscrewsandwiring ).
bottomofdevice .
2. Structure and Function
fixthedevice tothebackplate.
.mounting paper
RS485
TCP/IP
Lock
Sensor
Alarm
RS485 Converter
Exit Button
ExternalReader
DoorBell
%
%
%
%
%
BUTT
BUTT
BUTT
BUTTBUTTON
ON
ON
ONON
EXIT
EXIT
EXIT
EXITEXIT
AccessControlSystemFunction
(1) If a registered user verified, the device will export the
signal to unlock the door.
(3) If only the dllegalremoved, the deviceevice being ily
(4) is Externalcardreadersupported.
(5) is it is Externalexitbuttonsupportedconvenient to ,
(1) ThesystemsupportsNOlockandNClock. ForexampletheNOlock normally open at power (
(2) When the electrical lock is connected to the Access Control System, you need to parallel one FR107
(2) Doorsensorwilldetecttheonoffstate If the door is -
unexpected opened or improperly closed, the alarm signal
(digital value) will be triggered.
will export alarm signal.
open the door inside.
(7) Supports, modeswith/RS485 TCPIP to connect PC. One
PC can manage multiple devices.
(6) External door bell is supported.
NCLOCK
-
+
DC12V
+
NCLOCK
+
-
NOLOCK
-
-
FR 107
+
-
FR 107
-
+
DC12V
+
-
-
+
DC power
-
+
DC12V
-
+
DC power
+
-
FR 107
+
(1) Sharepower with the lock:
(2) Does not sharepower with the lock:
Devicedoesnotsharepowerwith the lock :
①:‘I’: device output current, ‘’: lock voltage,’: lock current.UILOCKLOCK
Devicesharepowerwith the lock:
U=12V, I-I1AAndthedistancebetweenthelockandtheLOCKLOCK> device is 10 meters.……①;
A. U=12V, I-I1AhedistancebetweenthelockandtheLOCKLOCK;.;. B ULOCK12V C T device is >10 meters.
Warning: No operating with power on
onis connected with "NO" and "COM" terminals, and the NC lock is connected with)
diode (equipped in the package) to prevent the self-inductance EMF affect the system,
"NC" and "COM" terminals.
do not reverse the polarities.
1
4.OtherConnection
5.Power Connection
6
5
4
+
Door Bell
%
%
%
%
%
EXIT
EXIT
EXIT
EXIT EXIT
BUTT
BUTT
BUTT
BUTTBUTTON
ON
ON
ONON
Alarm Power
Exit Button
Door Sensor
5Power Connection:.
Input DC 12V, 500mA (50mA standby)
Positive is connected with ‘+12V’, negative is connected
with ’GND’ ().do not reverse the polarities
DC12V
-
-
+
Alarm
Alarm Voltage output DC 12V
Warning: No operating with power on
GND
+12V
AccessControl Panel
6. Wiegand Output
The device supports standardWiegand 26
output, so you can connect it with most of the
7. Wiegand Input
supports to connect with cardreader.an independent
The device has the function ofWiegandinput signal . It
They are installed each side of the door, to control the
access control devices by now.
DATA0
GND
DATA1
DATA1
DATA0
GLED
RLED
BEEP
( Pleaseuse Wiegand signal extender in long distance or interferenceenvironment).
(2) To keep the stability of Wiegand signal, connect the device and the access control or card reader in same
(1) Please keep the distance between the device and Access Control or Card Reader less than 90 meters
‘GND’ in any case.
8OtherFunctions.
SideViewBackView
TamperMagnet
ResetButton
(1) Manual Reset:
(2) Tamper Function:
other restart it.abnormality, you can use ‘Reset’ function to
button hole with than 2mm).asharptool (the tip diameter less
Operation: Removetheblackrubber capthen sticktheReset ,
Ifthedevicedoesnotwork properly because of misoperation or
Indeviceinstallation, user need to put the magnet between the device
and movedthe back plate. If the device being illegally , and the magnet
being away from the device, it will trigger the alarm.
485 RS485++
There are two modes that the PC software communicate and exchange information with the device:
RS485 and TCP/IP, and supports remotecontrol.
9. Communication
(1) RS485Mode:
TerminalsPCSerialPorts
Please use specified RS485 wire, RS485 active converter
and bus-type wiring.
485 RS485--
Terminals definition please refers to the right table.
485+
485-
485+ 485-
RSBus485
485+ 485- 485+ 485-
RS485
Converter
IPAddress:192.168.1.100
SubnetMask:255.255.255.0
IPAddress:192.168.1.124
Subnet Mask:255.255.255.0
() : ACrossovercable Thedevice and PC connected
(2) TCP/IP Mode:
Two ways for TCP/IP connection.
directly.
Switch
(): BStraight cableThe device and PC connected to
LAN/WAN through switch/Lanswitch.
10. Cautions:
()2Werecommend the 3DCA12VpowersupplyPlease contact our technical stafffordetails. / .
()5Please connect the ‘GND’ before all the other wiring especially under the environment with much
()3Pleasereadcarefullytheterminaldescriptionandwiringbyrulestrictly . Anydamage
() 4Keep theexposedpartofwire less than 5mm, to avoid unexpected connection.
() 1Powercableisconnected after all the other wiring. If the device is working abnormally, please shut
caused byimproper operations will be out of the range of our guarantee.
damage the device, and it is not included in the warranty.
()6Do not change the cable type because of long distance between the power and the device.
down the power first, then make the necessary check. Kindly reminds you that any hot-plugging may
(7) Please use specified RS485 wire, RS485 active converter, and adopt bus-type wiring. If the communication
wire is longer than 100 meters, it is needed to parallel a terminal resistance on the last device of RS485 bus,
lock and access together.
and the value is about 120 ohm.
electrostatic.
GND
NO1
NO2
COM2
BELL+
BUT
COM1
SEN
NC1
BELL-
Purple
Brown
White
Red
Black
Yellow
Gray
Orange
Blue
Green
GND
+12V
Red
Black
GND
485+
WD1
WD0
485-
White
Black
Yellow
Blue
Green
IWD0
BEEP
GND
RLED
IWD1
GLED
+12V
Purple
White
Red
Black
Gray
Blue
Green
GND
NO1
NO2
COM2
BELL+
BUT
COM1
SEN
NC1
BELL-
Purple
Brown
White
Red
Black
Yellow
Gray
Orange
Blue
Green
GND
+12V
Red
Black
GND
NO1
NO2
COM2
BELL+
BUT
COM1
SEN
NC1
BELL-
Purple
Brown
White
Red
Black
Yellow
Gray
Orange
Blue
Green
GND
+12V
Red
Black
NOLOCK
-
+
DC12V
+
-
+
-
FR 107
GND
NO1
NO2
COM2
BELL+
BUT
COM1
SEN
NC1
BELL-
Purple
Brown
White
Red
Black
Yellow
Gray
Orange
Blue
Green
GND
+12V
Red
Black
GND
NO1
NO2
COM2
BELL+
BUT
COM1
SEN
NC1
BELL-
Purple
Brown
White
Red
Black
Yellow
Gray
Orange
Blue
Green
GND
+12V
Red
Black

Betygsätt denna manual

4.1/5 (9 Recensioner)

Produktspecifikationer

Varumärke: ZKTeco
Kategori: Tillträdeskontrollsystem
Modell: TF1700
Inbyggd display: Ja
Bredd: 62.5 mm
Djup: 41.5 mm
Höjd: 185 mm
fingeravtrycksläsare: Ja
Modell: Basic åtkomstkontrolläsare
Autentiseringstyp: Access chip/card, Biometric, Password
PC-anslutning: RJ-45
Kortkapacitet: 10000 kort
Produktens färg: Svart
Skärmtyp: OLED
Temperatur vid drift: -10 - 50 ° C
Internationellt skydd (IP) kod: IP65
DC-spänningsområde: 0 - 12 V
USB-port: Ja
Skärmstorlek (HxB): 64 x 128 mm
Knappsats integrerade: Ja
Åtkomstkod läsare: Ja
Tillgång chip / kortläsare: Ja
Knappsats, antal tangenter: 15
PC-ansluten: Ja
Logkapacitet: 50000

Behöver du hjälp?

Om du behöver hjälp med ZKTeco TF1700 ställ en fråga nedan och andra användare kommer att svara dig