Läs gratis den bruksanvisning för Aiphone IXW-HWCBP (4 sidor) i kategorin internt kommunikations system. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 2 recensioner. Har du en fråga om Aiphone IXW-HWCBP eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/4

IXW-HWCBP
Hand Wave Call Button and Surface Mount Box
IXW-HWCBP includes a touchless switch attached to a mounting plate, a PS-POE, and the SBX-2G/A
surface mount box. This device can be connected to any IX Series door station with a trigger input and a PoE
passthrough. It will place calls to the programmed station without having to touch the call button. The touchless
switch is powered by the PS-POE. The switch’s contact output will trigger a contact input on the door station. The
contact input will need to be programmed and assigned to a calling group. This instruction manual will show how
to connect the IXW-HWCBP to the door station and program the door station for contact input calling.
Wiring
A PoE+ switch is required when using the IXW-HWCBP. Connect a network cable from the PoE+ switch to LAN
1 of the IX Series door station. LAN 2 connects to the included PS-POE. Connect the power output of the
PS-POE to the red (+VDC) and black (Gnd) wires of the touchless switch. Connect the green (N/O) and yellow
(Common) wires of the touchless switch to contact input 1 on the IX Series door station (brown/blue wires on
CN2).
- Instructions -
Specifi cations
Dimensions: 4-¹³ " H x 4- " W x 4" D⁄ ⁷ ⁄
Package Contents
Qty 1 Panel with touchless switch
Qty 1 SBX-2G/A
Qty 1 PS-POE
Qty 4 speed nuts for panel mounting
Qty 4 screws for panel mounting
Qty 1 three-foot patch cable
Installation
1. Secure SBX-2G/A to wall
2. Connect included patch cable, power wires, and
a ground wire to PS-POE and place unit
inside the SBX-2G/A
3. Connect included patch cable to LAN 2 of IX
series door station
3. Connect touchless switch to input of IX series
door station and PS-POE
- Green (N.O.) to Brown (CN2 of IX-DV)
- Yellow (Common) to Blue (CN2 of IX-DV)
- White (N.C.) not used
- Red (+VDC) to + of PS-POE
- Black (GND) to - of PS-POE
4. Secure switch panel to SBX-2G/A
Back View
PoE+ Switch
Cat-5e / Cat-6
PS-POE
PoE IN
- +
N.C. (not used)
Red = +VDC
Black =Gnd
,;'9
IX-DV
IXW-HWCBP
If a PoE passthrough is
not available, connect
the PS-POE directly to
the PoE switch
Patch cable supplied
IXW-HWCBP Instr
0321
Aiphone Corporation
www.aiphone.com
tech@aiphone.com
800-692-0200

The fi rst step is to enable the contact input on the IX Series door station will connect to the
IXW-HWCBP. Open IX Support Tool and select the system to edit. Door stations can have up to 6
contact inputs. These instructions will show using contact input 1. In the upper left corner of the screen
click to switch from Station View Table View Station View to .
Enabling Door Station Option Input
1.1 - Option Input
Expand Option Input / Relay Output
Settings Option Input and click .
1.2 - Select a Station
Use the drop-down menu or click Next
to choose the station number of the door
station to be confi gured. Click Select.
1.3 - Option Input / Name
Select using the Option Input 1
drop-down menu and assign a .Name
1.4 - Choose a Function
Select for this option input.Call
1.5 - Contact Settings
Select for the Make Type and
0 (Immediate) Detection Time for the
Range.
Click to Update
save your settings.
Programming
Aiphone Corporation
|
www.aiphone.com
|
tech@aiphone.com
|
(800) 692-0200
Page 2
For more details about the features and information above, please contact Technical Support.

Door Station Option Input Call
The next step is to assign a call group to the trigger input. The call group for the trigger input, will be
the same group assigned to the call button.
2.1 - Call Origination
Expand and click Call Settings
Call Origination.
2.3 - Select an Input
Use the drop-down menu and
select .Option Input 1
2.4 - Select a Destination
Click under Open Call
Destination and select group
01 Priority. Use the drop-down
menu to select the calling
priority.
2.2 - Select a Station
Use the drop-down menu to
choose the station number of
the door station to be confi gured
and click .Select
Click to Update
save your settings.
Aiphone Corporation
|
www.aiphone.com
|
tech@aiphone.com
|
(800) 692-0200
Page 3
For more details about the features and information above, please contact Technical Support.
Produktspecifikationer
Varumärke: | Aiphone |
Kategori: | internt kommunikations system |
Modell: | IXW-HWCBP |
Behöver du hjälp?
Om du behöver hjälp med Aiphone IXW-HWCBP ställ en fråga nedan och andra användare kommer att svara dig
internt kommunikations system Aiphone Manualer
30 Juni 2025
29 Juni 2025
29 Juni 2025
12 Juni 2025
internt kommunikations system Manualer
Nyaste internt kommunikations system Manualer
22 Juni 2025
18 Juni 2025
16 Juni 2025
14 Juni 2025
14 Juni 2025
13 Juni 2025
1 Juni 2025
30 Maj 2025