Läs gratis den bruksanvisning för Aiphone IXW-HWCBP (4 sidor) i kategorin internt kommunikations system. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 2 recensioner. Har du en fråga om Aiphone IXW-HWCBP eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
IXW-HWCBP
Hand Wave Call Button and Surface Mount Box
IXW-HWCBP includes a touchless switch attached to a mounting plate, a PS-POE, and the SBX-2G/A
surface mount box. This device can be connected to any IX Series door station with a trigger input and a PoE
passthrough. It will place calls to the programmed station without having to touch the call button. The touchless
switch is powered by the PS-POE. The switch’s contact output will trigger a contact input on the door station. The
contact input will need to be programmed and assigned to a calling group. This instruction manual will show how
to connect the IXW-HWCBP to the door station and program the door station for contact input calling.
Wiring
1 of the IX Series door station. LAN 2 connects to the included PS-POE. Connect the power output of the
PS-POE to the red (+VDC) and black (Gnd) wires of the touchless switch. Connect the green (N/O) and yellow
(Common) wires of the touchless switch to contact input 1 on the IX Series door station (brown/blue wires on
CN2).
- Instructions -
Speci cations
Dimensions: 4-¹³ " H x 4- " W x 4" D
Package Contents
Qty 1 Panel with touchless switch
Qty 1 SBX-2G/A
Qty 1 PS-POE
Qty 4 speed nuts for panel mounting
Qty 4 screws for panel mounting
Qty 1 three-foot patch cable
Installation
1. Secure SBX-2G/A to wall
2. Connect included patch cable, power wires, and
a ground wire to PS-POE and place unit
inside the SBX-2G/A
3. Connect included patch cable to LAN 2 of IX
series door station
3. Connect touchless switch to input of IX series
door station and PS-POE
- Green (N.O.) to Brown (CN2 of IX-DV)
- Yellow (Common) to Blue (CN2 of IX-DV)
- White (N.C.) not used
- Red (+VDC) to + of PS-POE
- Black (GND) to - of PS-POE
4. Secure switch panel to SBX-2G/A
Back View
PoE+ Switch
Cat-5e / Cat-6
PS-POE
PoE IN
- +
N.C. (not used)
Red = +VDC
Black =Gnd
,;'9
IX-DV
IXW-HWCBP
If a PoE passthrough is
not available, connect
the PS-POE directly to
the PoE switch
Patch cable supplied
IXW-HWCBP Instr
0321
Aiphone Corporation
www.aiphone.com
tech@aiphone.com
800-692-0200
The rst step is to enable the contact input on the IX Series door station will connect to the
IXW-HWCBP. Open IX Support Tool and select the system to edit. Door stations can have up to 6
contact inputs. These instructions will show using contact input 1. In the upper left corner of the screen
click to switch from Station View Table View Station View to .
Enabling Door Station Option Input
1.1 - Option Input
Expand Option Input / Relay Output
Settings Option Input and click .
1.2 - Select a Station
Use the drop-down menu or click Next
to choose the station number of the door
station to be con gured. Click Select.
1.3 - Option Input / Name
Select using the Option Input 1
drop-down menu and assign a .Name
1.4 - Choose a Function
Select for this option input.Call
1.5 - Contact Settings
Select for the Make Type and
0 (Immediate) Detection Time for the
Range.
Click to Update
save your settings.
Programming
Aiphone Corporation
|
www.aiphone.com
|
tech@aiphone.com
|
(800) 692-0200
Page 2
For more details about the features and information above, please contact Technical Support.
Door Station Option Input Call
The next step is to assign a call group to the trigger input. The call group for the trigger input, will be
the same group assigned to the call button.
2.1 - Call Origination
Expand and click Call Settings
Call Origination.
2.3 - Select an Input
Use the drop-down menu and
select .Option Input 1
2.4 - Select a Destination
Click under Open Call
Destination and select group
01 Priority. Use the drop-down
menu to select the calling
priority.
2.2 - Select a Station
Use the drop-down menu to
choose the station number of
the door station to be con gured
and click .Select
Click to Update
save your settings.
Aiphone Corporation
|
www.aiphone.com
|
tech@aiphone.com
|
(800) 692-0200
Page 3
For more details about the features and information above, please contact Technical Support.

Produktspecifikationer

Varumärke: Aiphone
Kategori: internt kommunikations system
Modell: IXW-HWCBP

Behöver du hjälp?

Om du behöver hjälp med Aiphone IXW-HWCBP ställ en fråga nedan och andra användare kommer att svara dig




internt kommunikations system Aiphone Manualer

internt kommunikations system Manualer

Nyaste internt kommunikations system Manualer