AMX DX-RX-4K60 Bruksanvisning
                    AMX
                    
                    Inte kategoriserad
                    
                    DX-RX-4K60
                
                                
    Läs gratis den bruksanvisning för AMX DX-RX-4K60 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 14 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 7.5 recensioner. Har du en fråga om AMX DX-RX-4K60 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
DIP Switch Toggles – Default OFF (for Auto-setup, see next page) 
Before installing the units, find the scenario you are using in the table below and set the 
DIP switch toggles accordingly. Toggle #4 is reserved for future functionality. 
For standalone pair upgrades, set Toggles #1-2-3 to ON and connect one unit to a 
Controller. 
COMMON SCENARIOS 
TOGGLES 
Standalone Setup 
1 - 2 - 3 
AV signals only (plus serial/IR passthrough) 
OFF - OFF - OFF 
AV with Ethernet passthrough to networked device (plus serial/IR 
passthrough)* 
ON - OFF - OFF 
AV with NetLinx control of TX/RX unit and serial/IR ports** 
ON - ON - ON 
AV with NetLinx control of TX/RX unit and serial/IR ports, plus Ethernet 
passthrough to network device* 
ON - ON - ON 
Switcher Setup (TX/RX with Enova DGX/DVX /DGX 100 Series Switcher) 
1 - 2 - 3 
AV signals only 
OFF - OFF - OFF 
AV with Ethernet passthrough to networked device* 
ON - OFF - OFF 
AV with NetLinx control of TX/RX unit and serial/IR ports 
OFF - OFF - ON 
AV with NetLinx control of TX/RX unit and serial/IR ports, plus Ethernet 
passthrough to network device* 
ON - OFF - ON 
* Connect ICS LAN port of DXLink unit to network device (e.g., laptop, IP controlled 
projector, ICSLan Device). In standalone setup, connect ICS LAN port of other DXLink 
unit to network. 
** In standalone setup using NetLinx control of DXLink serial/IR ports, only one of the 
DXLink units should be connected to network (the unit with #1 Toggle enabled). 
Source Device 
Destination Device
DXLINK Transmitter  DXLINK Receiver
FIG. 3 DXLINK TX AND RX AS EXTENDER SOLUTION 
Mounting Options (Rack Trays and Mounting Brackets) 
For details on the four versatile mounting kit options for V Style modules (rack tray, rack 
tray with fill plates, surface mount, and pole mount), see www.amx.com
IMPORTANT: When mounting under a surface, the module should be mounted upright and 
lowered in the mounting bracket slots to provide an airflow gap between the surface and 
the vent holes. If not using V Style brackets, be sure to leave a gap between the top of 
the unit and the surface for heat to escape. 
Twisted Pair Cable Pinouts and RJ-45 LEDs 
The DXLink and ICS LAN 10/100 ports both use twisted pair cable. FIG. 4 shows two 
pinouts that can be used for either port. FIG. 5 shows the LEDs for each port. 
FIG. 4 RJ-45 PINOUTS 
FIG. 1 
DIP SWITCH TOGGLES ENABLE/DISABLE SPECIAL FUNCTIONALITY 
Overview 
The DX-TX-4K60 and DX-RX-4K60 transmit HDMI, audio, USB and control over twisted 
Yellow LED 
On - Speed status is 100 Mbps 
Off- Speed status is 10 Mbps 
ICS LAN 10/100 Port 
Green LED 
Yellow LED 
On - Authenticated HDCP 
Flashing - Video active; no HDCP 
Off- No Video 
DXLink Port 
pair cable. The TX also has an HDMI local loop out. DXLink Modules can be set up in 
one of three ways: 
•
Endpoint Mode (Switcher) – connect one or more to a switcher with an integrated 
Controller. 
•
Endpoint Mode (Standalone) – connect TX/RX pair directly to each other with one 
Green LED 
On - Link status is active 
Off- Link status is not active 
FIG. 5 RJ-45 PORTS 
On - Connection established 
Off- Connection not established 
connected to a NetLinx Central Controller via LAN or directly to Controller. 
•
Extender Mode (Standalone) – connect TX/RX pair directly to each other. 
These Modules support InstaGate Pro® and SmartScale® Technology. 
The Hardware Reference Manual – DXLink Twisted Pair 4K60 Transmitters/Receiver 
contains complete documentation (including full specifications and supported input 
and output resolutions); for details, see www.amx.com.
System Setup 
The DX-TX-4K60 and DX-RX-4K60 work with a switcher that supports DXLink 
Technology or as a stand-alone pair to transmit audio, video and control signals. The 
Transmitter receives audio and video from the HDMI source and transmits both audio 
and video over the DXLink twisted pair cable. This DXlink cable can be connected directly 
to a DXLink Receiver or to a DXLink input on a DXLink switcher where it can be routed to 
a DXLink output and connected to a DXLink Receiver. The DXLink Receiver converts the 
DXLink input to HDMI and analog audio outputs. On the Transmitter, stereo audio 
connections are provided as a supplemental audio input. Both the Transmitter and the 
Receiver support RS-232 for serial data transfer, USB, IR, and Ethernet. 
Destination Device 
Attaching Signal, Transport, and Control Cables 
Important Twisted Pair Cabling Requirements and Recommendations: 
•
DXLink cable runs require shielded category cable (STP) of Cat 6 (or better). 
•
For cable runs longer than 70 meters total, shielded category cable (STP) of Cat 6A 
or better is required. 
•
DXLink twisted pair cable runs for DXLink equipment shall only be run within 
a common building.* 
•
DXLink (RJ-45) connectors must not be used for connecting to a standard 
Ethernet Network. The connector is used for signal transport. 
•
Do not create a network (Ethernet) loop. A network loop is created when the 
enclosure and one or more of its DXLink Modules are connected to a common LAN 
(or a standalone pair when both endpoints connect to the same network). 
•
DXLink delivers 10.2Gb/s throughput over shielded category cable. Based on this 
bandwidth requirement, we recommend following industry standard practices 
designed for 10 Gigabit Ethernet when designing and installing the cable 
infrastructure. 
•
The cables should be no longer than necessary to reach the end-points. We 
recommend terminating the cable to the actual distance required rather than 
leaving any excess cable in a service loop. 
Source Device 
DXLINK Input Board 
Cat x 
DXLINK Output Board 
•
For more information, see the Hardware Reference Manual – DXLink Twisted Pair 
4K60 Transmitters/Receiver. 
HDMI IN 
DXLINK Transmitter 
Up to330ft 
(100m) 
D
C 
F 
L 
T 
LAN 100/1000 
Cat x 
Up to330ft 
(100m) 
DXLINK Receiver 
HDMI OUT 
* “Common building” is defined as: Where the walls of the structure(s) are physically 
connected and the structure(s) share a single ground reference. 
For more details and helpful cabling information, reference the white paper titled 
“Cabling for Success with DXLink” available at www.amx.com 
or contact your AMX 
representative. 
FIG. 2 DXLINK TX AND RX AS ENDPOINTS WITH COMPATIBLE DXLINK EQUIPMENT 
Cat x Up to330ft(100m)
HDMI IN
HDMI OUT
ON 
1 2 3 4
ID USB MODE
QUICK START GUIDE 
DXLink™ Twisted Pair 4K60 Transmitter/Receiver 
Produktspecifikationer
| Varumärke: | AMX | 
| Kategori: | Inte kategoriserad | 
| Modell: | DX-RX-4K60 | 
Behöver du hjälp?
Om du behöver hjälp med AMX DX-RX-4K60 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad AMX Manualer
                        
                         2 Januari 2025
                        
                    
                                                            
                        
                         2 Januari 2025
                        
                    
                                                            
                        
                         2 Januari 2025
                        
                    
                                                            
                        
                         2 Januari 2025
                        
                    
                                                            
                        
                         2 Januari 2025
                        
                    
                                                            
                        
                         27 December 2024
                        
                    
                                                            
                        
                         7 December 2024
                        
                    
                                                            
                        
                         25 September 2024
                        
                    
                                                            
                        
                         25 September 2024
                        
                    
                                                            
                        
                         24 September 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Invacare
- Star Micronics
- Pigtronix
- Naim
- Celexon
- NightStick
- LightZone
- Ices
- WestBend
- IODD
- Schaffner
- Scheppach
- Adastra
- SAVS
- A-Designs
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025