Troubleshooting and Service
1. Consult the Troubleshooting from the APC by Schneider Electric Web site, www.apc.com.
2.If the problem persists, contact Schneider Electric IT (SEIT) Customer Support through the
APC by Schneider Electric Web site, www.apc.com.
 a. Note the model number and serial number and the date of purchase. The model and 
serial numbers are located on the rear panel of the unit and are available through the 
LCD display on select models.
 b. Call SEIT Customer Support and a technician will attempt to solve the problem over 
the phone. If this is not possible, the technician will issue a Returned Material 
Authorization Number (RMA#).
 c. If the unit is under warranty, the repairs are free. 
 d. Service procedures and returns may vary internationally. Refer to the APC by 
Schneider Electric Web site for country specific instructions.
3. Prepare to troubleshoot the problem over the phone. If this is not successful, and the unit is
still  under  warranty,  the  Technical  Support  Representative  will  provide  all  necessary
information to return the unit for replacement.
Back-UPS
 BX500CI
Adjust Transfer Voltage and 
Sensitivity Settings
User Guide
4
1
™
Place the Back-UPS to avoid:
 • Direct sunlight
 • Excessive heat
 • Excessive moisture
Connect  the  battery  by  pulling  the  battery
connector  handle  down,  and  then  pushing  it
into the unit.
Plug the Back-UPS BX500CI power cord directly into a wall outlet; not into a
surge protector or power strip.
Press the ON/OFF button to turn on the unit.
The green LED status indicator confirms that the Back-UPS is on and ready to 
provide protection.
The Back-UPS should charge for at least 10 hours to ensure sufficient runtime. 
The unit is being charged whenever it is connected to AC power, whether the 
unit is turned ON or OFF.
2
1
3
2
Place and Power On
Battery Replacement
The battery in the Back-UPS BX500CI is not user-replaceable. Contact SEIT Technical Support for a
list of authorized service centers near you. 
Warranty
Register your product on-line. http://warranty.apc.com
The standard warranty is two (2) years from the date of purchase. SEIT standard procedure is to 
replace the original unit with a factory reconditioned unit. Customers who must have the original unit 
back due to the assignment of asset tags and set depreciation schedules must declare such a need at 
first contact with an SEIT Technical Support representative. SEIT will ship the replacement unit once 
the defective unit has been received
 by the repair department, or cro
ss-ship upon the receipt of a valid 
credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground freight trans-
portation costs to ship the replacement unit to the customer.
APC by Schneider Electric IT Customer 
Support Worldwide
For country specific customer support, go to the APC by Schneider Electric Web site, www.apc.com. 
EN 990-5174   07/2013
©  2013 APC by Schneider Electric. APC, the APC logo and APC, the APC logo, and Back-UPS are owned
by Schneider Electric Industries S.A.S. or their affiliated companies. All other trademarks are property of
their respective owners.
bu054a
ON/OFF 
button  and 
LED Status 
Indicator
Battery 
connector
Battery 
backup 
and surge 
protected 
outlets
Specifications
  Input Voltage / Frequency 230 VAC nominal / 45-65 Hz
Brownout Transfer / 
Over-voltage Transfer
160 ±8% VAC, typical / 
280 VAC, typical
  Output UPS Capacity (total) 500 VA / 300 W
 Voltage On Battery 230 Vac rms 
 Frequency - On Battery 50 Hz, 60 Hz ±1 Hz
 Transfer Time 50 Hz: 6ms typical, 10ms maximum 
60 Hz: 5ms typical, 8ms maximum
Protection 
and Filter  AC Surge Protection 273 joules
 AC Input Resettable circuit breaker
  Battery Type (maintenance-free) Sealed, lead-acid battery
 Average Life 2 - 5 years depending on the number of 
discharge cycles and environmental 
temperature
 Typical Recharge Time  10 Hours 
  Physical Net Weight 5.1 kg 
 Dimensions (H x W x D) 18.55 cm x 11.5 cm x 21.3 cm 
3
Status Indicators
Automatic Voltage Regulation boosts the AC voltage when it drops below safe levels. This allows 
the equipment plugged into the unit to operate
 during low voltage c
onditions, conserving the 
battery power in the event of a power cut.
The Back-UPS will switch to battery power if the input voltage level becomes too low for the 
Automatic Voltage Regulation to compensate, or if the AC power is distorted.
If the Back-UPS switches to battery power too frequently or too infrequently, adjust the transfer 
voltage and sensitivity settings:
1. Ensure the Back-UPS is off. Plug it into AC power. 
2. Press and hold the ON/OFF button until the LED repeatedly flashes. The unit is now in 
Program Mode. 
3. Release the button. The LED will flash once, twice, or three times per second, indicating the 
current setting.
4. Press the ON/OFF button within two seconds to change the setting. Each time the button is 
pressed, the LED will flash at a different rate: once, twice, or th r second, ree times pe
indicating the new setting. Continue pressing the button until
 the desired sett
ing is reached. 
If the button is not pressed within five seconds, the Back-UPS will exit the Program Mode.
5. To exit Program Mode, release the button and wait for the LED to stop flashing.
Transfer Voltage and Sensitivity Settings
LED Flashing
Voltage 
Sensitvity 
Setting
Input Voltage 
Range (for AC 
Operation)
Usage
     Once per second Low 155 - 280 The Back-UPS will switch to battery 
power less often. Use with equipment 
that is not sensitive to low or high 
level voltage levels or minor voltage 
waveform distortions.
 Twice per second Medium 
(factory 
default)
 160 -280 Default, use in normal conditions.
Three times per 
second 
   High 165 - 270 The Back-UPS will switch to battery 
power during any small fluctuation in 
voltage. Use with equipment that is 
sensitive to low or high level voltage 
levels or minor voltage waveform 
distortions.
LED Status 
Indicator  Audible Alarm Condition
   On Off On-line - UPS is supplying conditioned AC power 
to the load
On (Off 
during 4 
beeps)
4 beeps repeated 
every 30 
seconds
On-Battery - Back-UPS is supplying battery 
power 
 Flashing Rapid Beeping 
(every 1/2 
second) 
Low Battery Warning - The UPS has 1.5 minutes 
of remaining battery power
   Flashing Constant tone Bad Battery Detected - Battery needs to be 
charged, or is at end of life.
 Off Short beep every 
4 seconds
Low Battery Shutdown - During On Battery 
operation the battery power was almost completely 
exhausted
   Off Constant Tone On Battery Overload - Connected equipment 
requires more power than provided by the Back-
UPS battery.
   On Constant Tone On Line Overload - The power drawn by the 
connected equipment exceeds the power capacity 
of the battery backup
 Flashing Chirp every 2 
seconds
Charger Warning - Back-UPS has experienced an 
internal problem, but continues to power the load. 
Contact Schneider Electric IT (SEIT) Technical 
Support.
   Off Constant Tone Charger Fault - Back-UPS has an internal 
problem, and is no longer powering the load. 
Contact SEIT Technical Support 
IEC jumper cable for 
PC connection
AC power cable
4
Produktspecifikationer
| Varumärke: | Apc | 
| Kategori: | Server | 
| Modell: | BX500CI | 
Behöver du hjälp?
Om du behöver hjälp med Apc BX500CI ställ en fråga nedan och andra användare kommer att svara dig
Server Apc Manualer
                        
                         14 December 2024
                        
                    
                                                            
                        
                         7 December 2024
                        
                    
                                                            
                        
                         27 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         8 September 2024
                        
                    
                                                            
                        
                         31 Augusti 2024
                        
                    
                                                            
                        
                         30 Augusti 2024
                        
                    
                                                            
                        
                         27 Augusti 2024
                        
                    
                                                            
                        
                         25 Augusti 2024
                        
                    
                                                            
                        
                         18 Augusti 2024
                        
                    
                                                            Server Manualer
- Jung
- Fujitsu
- EMC
- Western Digital
- Opengear
- Kathrein
- EXSYS
- Technics
- Vivotek
- Moxa
- Digital Watchdog
- Lantronix
- Mobotix
- Smart-AVI
- Monacor
Nyaste Server Manualer
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025