Apc Line-R LE600 Bruksanvisning
                    Apc
                    
                    Inte kategoriserad
                    
                    Line-R LE600
                
                                
    Läs gratis den bruksanvisning för Apc Line-R LE600 (1 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 37 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 19 recensioner. Har du en fråga om Apc Line-R LE600 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/1
                    
                    
                    
Thank you for purchasing APC’s Line-R Automatic Voltage Regulator! Please fill out and
mail the product warranty registration form, or fill out an online form at www.apc.com.
The Line-R automatically corrects brownouts (by boosting low voltage) and overvoltages (by
stepping down high voltage) from the power utility service to levels that are safe for computers,
as well as other sensitive equipment. APC’s Line-R provides the highest degree of protection
from  line  voltage  sags  and  swells,  and  has  been  designed  for  many  years  of  reliable,
maintenance-free service.
Applications
CAUTION: The total power consumption of all equipment plugged into the Line-R must not
exceed the “Maximum Output Power Capacity” rating listed in the Specifications table. A total
load in excess of this rating will cause the power switch/circuit breaker to “trip”.
The Line-R is designed for use with voltage sensitive equipment such as a: computer, monitor,
inkjet printer, scanner or fax. It is also designed for use with home electronics (TVs, stereos,
CD players, etc.).
Appliances not suitable for use with the Line-R are items such as refrigerators, freezers, power
tools,  air conditioners,  dehumidifiers, blenders, or any device that employs  an  AC motor  for
operation. Not for use with life sustaining equipment and any device with a power requirement
exceeding the “Maximum Output Power Capacity” rating listed in the Specifications table.
Features
ON/OFF Power Switch/Circuit Breaker
The Line-R provides an ON/OFF power switch/circuit breaker which functions as the master
power  switch  for  the  Line-R  and  all  devices  connected  to  the  device.  It  also  functions  as  a
circuit breaker to protect the unit from being overloaded. If the circuit breaker “trips”, unplug
the last device connected to the unit, turn the power switch/circuit breaker to the OFF position,
place the power switch/circuit breaker to the ON position.
Line-R™
Automatic Voltage Regulator
Models LE600 and LE1200
Lights when input voltage is high. 
Flashes  when  input  voltage  is  above  rated  Input
Voltage Range.
Input voltage is normal.
Lights when input voltage is low. 
Flashes  when  input  voltage  is  below  rated  Input
Voltage Range.
ON/OFF  Power  Switch/Circuit  Breaker  applies  and
removes power to/from the Line-R. This switch also
functions  as  a  circuit  breaker  in  the  event  of  an
over-load condition. ON/OFF
Power Switch/
Circuit Breaker
AC Outlets (4)
(connect equipment here)
Transformer
Block AC 
Outlet
AC Plug
(to wall outlet)
Building Wiring 
Fault Indicator
(see Plug the 
Line-R into Wall 
Outlet)
User Selectable Voltage Switch
(see Select Input Voltage)
Installation
• Placement -  Please  install the Line-R in a  protected environment  free of  excessive dust,
mechanical vibration, inflammable gases and explosive or corrosive atmospheres.
Do  not  block  the  top  or  side  air  vents  on  the  unit.  Allow  1  inch  (2.5  cm)  minimum  vent
clearance.
• Select  Input  Voltage  -  The  Line-R  provides  a  three-position  User  Selectable  Voltage
Switch for adjusting the input voltage for the region where it is being used (example: Mexico
-  127V,  United  States  -  120V,  or  Jamaica  -  110V).  Slide  the  switch  to  select  the  proper
voltage for your location.
• Plug the Line-R into Wall Outlet - Plug the Line-R into a grounded AC wall outlet. If the
Building Wiring Fault Indicator is lit, the building wiring presents a potential shock hazard
and should be serviced by a qualified electrician before putting this device into service. The
Line-R should only be used in buildings having proper grounding, with conductors protected
by fuses or circuit breakers.
• Connect Your Equipment - Plug equipment into the Line-R rear-panel outlets and switch 
the equipment ON. The equipment will not be powered until the Line-R is switched ON. 
CAUTION: The total power consumption of all equipment plugged into the Line-R must not
exceed the ratings listed in the Specifications table below. A total load in excess of the listed
ratings will cause the ON/OFF power switch/circuit breaker to “trip”. 
• Switch ON the Line-R - Press the front panel ON/OFF power switch/circuit breaker to the
ON (l) position. This switch may be used as the master ON/OFF switch for the device and all
equipment connected to the unit.
Specifications
Characteristics Model LE600 Model LE1200
Maximum Output Power 
Capacity
600 W or 600 VA 1200 W or 1200 VA
Nominal Output Voltage 110, 120, or 127 (User Selectable)
Nominal Input Current 5 A   10 A 
Input Voltage Range 80 - 130V (Selector Switch set to 110V) 
85 - 140V (Selector Switch set to 120V) 
90 - 150V (Selector Switch set to 127V) 
Maximum Input Voltage 250V
Surge Energy 702 Joules
Output Regulation +6 to -12%
Response Time < 2 AC Cycles
Efficiency >93%
Nominal Frequency 50/60 Hz
Number of Outlets 4
Operating Temperature 32 - 104°F (0 - 40°C)
Relative Humidity 0 - 95% Non-condensing
Dimensions 4.6 x 8.4 x 5.5 inches (118 x 214 x 141 mm)
Weight 7.25 lb (3.3 kg) 9.7 lb (4.4 kg)
2.5 cm
(1 inch)
Limited Warranty
Schneider Electric IT (SEIT) warrants its products to be free from defects in materials and 
workmanship under normal use and service for the lifetime of the original purchaser. Its 
obligation under this warranty is limited to repairing or replacing, at its sole option, any such 
defective products. To obtain service under warranty you must obtain a Returned Material 
Authorization (RMA) number from SEIT or an SEIT Service Center with transportation 
charges prepaid and must be accompanied by a brief description of the problem and proof of 
date and place of purchase. This warranty applies only to the original purchaser.
APC by Schneider Electric IT Customer Support Worldwide 
For country specific customer support, go to the APC by Schneider Electric Web site, www.apc.com.
© 2014 APC by Schneider Electric. APC, the APC logo, SurgeArrest and Line-R are owned by Schneider 
Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective 
owners.
EN 990-1286C
07/2014
Produktspecifikationer
| Varumärke: | Apc | 
| Kategori: | Inte kategoriserad | 
| Modell: | Line-R LE600 | 
Behöver du hjälp?
Om du behöver hjälp med Apc Line-R LE600 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Apc Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         28 Januari 2025
                        
                    
                                                            
                        
                         11 December 2024
                        
                    
                                                            
                        
                         11 December 2024
                        
                    
                                                            
                        
                         5 December 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         14 Oktober 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Honor
- Sunwoda
- Basetech
- Musser
- Corsair
- Plustek
- Norton Clipper
- Melinera
- Yellow Garden Line
- Martha Stewart
- Broil King
- Intermec
- Vitek
- StrikeMaster
- Senseca
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025