Aube TH115 AF Bruksanvisning
Läs gratis den bruksanvisning för Aube TH115 AF (3 sidor) i kategorin Termostat. Guiden har ansetts hjälpsam av 15 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 8 recensioner. Har du en fråga om Aube TH115 AF eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/3
                    
                    
                    
TH115 A/F/AF       400-115-003-B                    27/2/07                    1/2
Aube’s  TH115  programmable  thermostats  have  three  temperature
control modes:
1 Place the switch in Standby to cut power to the heater when not in use (e.g., in the sum-
mer). This will not affect the time and temperature settings.
2 If your thermostat is installed on a power base equipped with a ground fault protection,
to reset the ground fault protection, switch the thermostat to Standby and back to On.
3 The thermostat displays the percentage of heating time required to maintain the desired
temperature. For example,   is displayed when heating is activated 40 percent of the
time.
4 GFI appears when the ground fault protection has tripped.
Some  thermostat  configurations  can  be  modified  via
switches on the back of the faceplate (control module).
Default (factory) settings are inside the gray cells.
nRefer to the installation 
instructions of the power 
base.
oInsert the tabs at the top of 
the control module in the slots 
at the top of the power base.
pSecure the control module 
using the captive screw 
underneath the base.
NOTE
: Keep the thermostat's air vents clean and unobstructed at all times.
nPress the Hour button to set the hour.
oSet the Min button to set the minutes.
pSet the Day button to set the day.
qPress Mode/Ret to exit. 
The thermostat can automatically re-adjust its clock at Daylight Sav-
ings Time changeover. When this function is enabled (On), the ther-
mostat switches to Daylight Savings Time on the second Sunday of
March and to normal time on the first Sunday of November.
NOTE: The function is disabled (default setting) when the clock loses
its setting.
nPress the Day DLS button (3 seconds) until   appears 
on the screen.
oPress the   to toggle between On (enabled) and Off 
(disabled).
pPress the Day button briefly. The year setting is dis-
played.
qPress the   to set the current year.
rPress the Day button briefly. The month setting is dis-
played.
sPress the   to set the current month.
tPress the Day button briefly. The date setting is dis-
played.
uPress the   to set the current date.
vPress Mode/Ret to exit.
The display illuminates for 12 seconds when the backlight button is
pressed.
When either of the   buttons is pressed, the display also illuminates
for  12  seconds.  The  setpoint  temperature  appears  for  5  seconds,
then the actual (measured) temperature is displayed.
The thermostat normally displays the actual (measured) temperature.
To view the setpoint, press one of the   buttons once. The setpoint
will appear for the next 5 seconds.
To change the setpoint, press one of the   buttons until the desired
temperature is displayed. To scroll faster, press and hold the button.
The thermostat has 3 preset temperatures:
 Comfort temperature 
 Economy temperature 
 Vacation temperature 
To  use  a  preset  temperature,  press  the  corresponding  button.  The
corresponding icon  ,   or   will be displayed.
The following table shows the intended use and the default setting of
each of the preset temperatures.
To store a preset temperature:
nSet the desired temperature using the   buttons.
oPress and hold the corresponding button until the corresponding 
icon is displayed.
n
n
n
nn 1.
A mode:  controls the ambient air temperature
F mode:  controls  the  floor  temperature  using  an
external temperature sensor
AF mode:  controls the ambient air temperature
 maintains the floor temperature within desired
limits using an external temperature sensor
Display
% of heating time 1 to 24% 25 to 49% 50 to 74% 75 to 99% 100%
o
o
o
oo 2.
# Configurations UP DN
1 Display format °F / 12 h °C / 24 h
2Early Start a
a. Early Start can be used in Automatic mode only. When this function is enabled, the 
thermostat calculates the optimal time to start heating in order to obtain the desired 
temperature by the set time. The thermostat re-assesses the start time daily based 
on the previous day’s results.
Enable Disable
3Temperature control mode b
b. To select the F mode, place the switch in the F position. To select the AF mode, 
place the switch in the AF position and ensure that the remote temperature sensor 
is connected to the thermostat. To select the A mode, place the switch in the AF 
position and ensure that the remote temperature sensor is NOT connected to the 
thermostat.
F AF
p
p
p
pp 3.
On/Standby switch  1 
and GFCI reset  2
Day and time 
settings
Temperature 
adjustment buttons
Program button
Mode selection /
program exit
Temperature display
Mode display
Period display
Temperature 
preset buttons
Time and day display
Percentage of 
heating time 3
Backlight button
Program 
clear button
Preset temperature 
indicator
Appears when the 
setpoint is displayed
Temperature control 
mode indicator
Ground fault indicator 4
Power base
Control module
Air vents
Air vents
q
q
q
qq 4.
r
r
r
rr 5.
s
s
s
ss 6.
Icon Intended use A/AF modes F mode
Comfort 
(when at home) 21 °C (70 °F) 28 °C (82 °F)
Economy 
(when asleep or away from home) 17 °C (63 °F) 20 °C (68 °F)
Vacation 
(during prolonged absence)  10 °C (50 °F) 10 °C (50 °F)
Produktspecifikationer
| Varumärke: | Aube | 
| Kategori: | Termostat | 
| Modell: | TH115 AF | 
Behöver du hjälp?
Om du behöver hjälp med Aube TH115 AF ställ en fråga nedan och andra användare kommer att svara dig
Termostat Aube Manualer
                        
                         13 Augusti 2024
                        
                    
                                                            
                        
                         4 Augusti 2024
                        
                    
                                                            
                        
                         26 Juli 2024
                        
                    
                                                            
                        
                         26 Juli 2024
                        
                    
                                                            
                        
                         24 Juli 2024
                        
                    
                                                            Termostat Manualer
- Nest
 - Renkforce
 - Tellur
 - Heimeier
 - Warmup
 - Viessmann
 - Thermy
 - TP Link
 - Hive
 - Zehnder
 - ATAG
 - Robertshaw
 - Avidsen
 - Enda
 - Gira
 
Nyaste Termostat Manualer
                        
                         13 Oktober 2025
                        
                    
                                                            
                        
                         12 Oktober 2025
                        
                    
                                                            
                        
                         12 Oktober 2025
                        
                    
                                                            
                        
                         5 Oktober 2025
                        
                    
                                                            
                        
                         2 Oktober 2025
                        
                    
                                                            
                        
                         2 Oktober 2025
                        
                    
                                                            
                        
                         29 September 2025
                        
                    
                                                            
                        
                         28 September 2025
                        
                    
                                                            
                        
                         28 September 2025
                        
                    
                                                            
                        
                         28 September 2025