Läs gratis den bruksanvisning för Avtec AXWO (5 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 4 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 2.5 recensioner. Har du en fråga om Avtec AXWO eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/5
OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
888-994-7636, fax 888-864-7636
uniedbrands.net
PART NUMBER PP MNL2207, REV. A (08/23)
This manual provides information for:
VENTILATION SYSTEMS
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED
IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Avtec suggests
that if you are suspicious of damage to make a notation on the delivery
receipt. It will be the responsibility of the consignee to le a claim with the
carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Avtec reserves the
right to make changes in design and specications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER _________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
INSTALLATION INSTRUCTIONS
Avtec hoods are provided with adjustable hanging brackets designed to receive
1/2” threaded rod with a 1/2” nut and washer. Supporting rods must be
connected to all factory installed brackets. Recommended hanging height is 6’-
6” above nished oor for canopies. Low side wall ventilators should be installed
directly upon a Avtec base or on a re rated wall. If wall mounted, the bottom of
the vent should be 36” above nished oor.
ALL AVTEC VENTILATION SYSTEMS MUST BE INSTALLED IN ACCORDANCE
WITH NFPA-96, REMOVAL OF SMOKE AND GREASE-LADEN VAPORS FROM
COMMERCIAL COOKING EQUIPMENT.
BAFFLE FILTER (AF) SERIES
Model AF ventilators are listed by UL and are built in accordance of NFPA-96
for use with UL listed re extinguishing systems for duct hood protection. They
are available with or without an automatic re damper. They utilize UL classied
removable bafe lters to extract grease and provide a limited re barrier. The
canopy contains a hidden grease trough and removable cup. Surface, plenum
and duct collar re extinguishing systems may be factory supplied.
MODULAR GREASE EXTRACTORS (AX) SERIES
Model AX ventilators are listed by UL and are built in accordance of NFPA-96 for
use with UL listed re extinguishing systems for duct hood protection. They are
available with or without an automatic re damper. These models utilize high
velocity removable grease extractors. The canopy contains a hidden grease
trough and removable cup. Surface, plenum and duct collar re extinguishing
systems may be factory supplied.
FIGURE 1
FIGURE 3 FIGURE 4
HOOD FACE
T-MOLDING
C-CHANNEL
FIGURE 2
INSULATED
SUPPLY DUCT
FIRE DAMPER &
VOLUME CONTROL
DAMPER
FLUID WEL
D
EXHAUST DUCT
ACCESS
PANEL
FRONT OR BACK
NOTE: HOLES DRILLED THROUGH HOOD ANGLE BY
INSTALLER AFTER BRACKET ATTACHMENT
POINTS HAVE BEEN DETERMINED.
HOOD
ANGLE
OF HOOD
HANGER BRACKET DETAIL
HANGER ROD
PRE-DRILLED
HOLE, ACCEPTS
UP TO 1/2"ÿ ROD
5/16" BOLT
HOLE, ACCEPTS
PRE-DRILLED
NUT
HANGER ROD
S.S. NUT & BOLT
BY OTHERS
Information contained in this document is known to be current and accurate at the time of printing/creation. Reference our product line website for the most updated
product information and specications. © 2023 Electrolux Professional, Inc. All Rights Reserved.
2 OM-VENTILATION SYSTEMS
EXHAUST
DUCT IS
FLUID
WELDED
TO
COLLAR
GREASE
TERMINATOR
OR
GREASE TROUGH
CEILING
EXHAUST DUCTALL WELD
CONSTRUCTION
HING
40" MINIMUM
10' - 0" MINIMUM
IMPORTANT - READ FIRST - IMPORTANT
CAUTION: DO NOT ATTEMPT TO SERVICE THIS UNIT YOURSELF AS REMOVING COVERS
MAY CAUSE UNNECESSARY EXPOSURE TO DANGEROUS VOLTAGE.
CAUTION: NEVER CONNECT THE UNIT TO A POWER SOURCE WHILE STANDING IN
WATER. WET HANDS AND WET FLOORS SHOULD BE AVOIDED WHEN
CONNECTING ANY ELECTRICAL APPLIANCE TO A POWER OUTLET.
CAUTION: FANS MAY HAVE MULTIPLE POWER CONNECTIONS. MAKE SURE ALL FANS
ARE ISOLATED FROM POWER PRIOR TO PERFORMING MAINTENANCE.
AUTO WASH DOWN (AW) SERIES
Model AW ventilators are listed by UL and are built in accordance of NFPA-96 for use
with UL listed re extinguishing systems for duct hood protection. They are available
with or without an automatic re damper. These systems utilize a high velocity grease
extractor and an integral water wash system cleans the inside of the grease
extraction chamber either by manual activation of the Wash Start button or by a
programmable timer. The duration of the wash is electronically controlled. The
wash system is also activated by an electrical thermostat or a manual switch in
the event of a re condition. A surface re extinguishing system is required and
may be factory supplied.
CANOPIES
1. Check all local codes prior to installation. Special requirements may be
necessary depending upon building material construction.
2. Move crated hood to location of installation and very carefully uncrate hood.
3. Raise hood to proper hanging height.
4. Suspend hood from adequate roof supports using 1/2” threaded rods with
nuts and washers (See Fig. 1).
5. Level hood left to right and front to back.
6. Brackets are provided for hoods which are to be installed end to end or back
to back. Bolt brackets together using 3/8” bolt through holes provided (See
Fig. 2).
7. Install C channel where the ends of the hood meet and install T moldings on
front face of hoods where they join. High temperature silicone can be used
to install channel and T moldings (See Fig. 3).
8. For make-up air hoods, the supply collar with built-in UL listed re damper
and air volume damper must be installed per instructions on collar.
9. Provide a removable service door in supply duct near re damper (See Fig.
4).
EXHAUST FAN & DUCT
1. Check all local codes prior to installation.
2. All exhaust fans are supplied with a hinge kit and grease box.
3. The exhaust fan curb should be installed directly above the hood if possible.
Always maintain the shortest duct run possible.
4. Cut hole and seal exhaust fan curb to roof.
5. Duct shall be sized to provide air velocities not exceeding 1200 FPM.
6. Install hinges and airline cable on exhaust fan cap and metal curb.
Remember to leave ample room for fan to tilt back. Fan will remain in tilted
back position.
7. Install grease collection box on side of fan that has grease tube discharge.
8. The exhaust duct must be constructed of 16 gauge carbon steel or 18 gauge
stainless steel. All seems must be uid welded.
9. A duct transition should be provided below exhaust fan inlet.
10. The exhaust duct must be uid welded to hood collar.
11. Make all necessary electrical connections and check fan for proper rotation.
NOTE: Fan will exhaust air running in wrong direction.
WALL ATTACHMENT
Control panels are provided with all auto wash type ventilators (Model AW) and
are optional with all bafe lter type (AF) and modular grease extractor type (AX).
Control panels with models (AF) and (AX) do not have the auto wash plumbing
assembly compartments.
Control panel dimensions and connection detail are shown on the enclosed shop
drawing. Panels may be surfaced mounted, partially recessed or fully recessed.
FIGURE 5
FIGURE 6 FIGURE 7
A
A
B
B
FIGURE 8 FIGURE 9
ENCLOSURE TOP
ENCLOSURE
SIDE
FIGURE 10 FIGURE 11
78" A.F.F.
END SEAM CAP
CENTER SEAM CAP
END SEAM CAP
SUPPLIED STAINLESS BOLTS
AND ACORN NUTS


Produktspecifikationer

Varumärke: Avtec
Kategori: ej kategoriserat
Modell: AXWO

Behöver du hjälp?

Om du behöver hjälp med Avtec AXWO ställ en fråga nedan och andra användare kommer att svara dig




ej kategoriserat Avtec Manualer

Avtec

Avtec AXWO Bruksanvisning

21 September 2025

ej kategoriserat Manualer

Nyaste ej kategoriserat Manualer