Läs gratis den bruksanvisning för Best ILB3 (4 sidor) i kategorin ventilationskåpa. Guiden har ansetts hjälpsam av 4 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 2.5 recensioner. Har du en fråga om Best ILB3 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
Page 1
MODEL ILB3
IN-LINE BLOWER
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent power
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
to prevent backdrafting. Follow the heating equipment
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
corn Beef Flambe).
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-
lent steam explosion will result.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
!
FOR DOMESTIC COOKING ONLY
!
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on Kitchen Fire Safety Tips published by NFPA.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
WARNING
TABLE OF CONTENTS
This manual is divided into sections as follows:
!
TYPICAL INSTALLATION
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
!
MOUNTING OPTIONS
!
WIRING PLATE POSITION
!
DUCTING OPTIONS
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
!
USE AND CARE
!
SERVICE PARTS
!
WARRANTY
Page 2
MODEL ILB3
DUCTING (Horizontal blower discharge)
Two ways to connect ductwork to a factory-shipped unit.
ROOF CAP
ROUND
ELBOW
ROUND DUCT
WALL
CAP
IMPORTANT: Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating
the ventilator.
10 ROUND DUCT
(OUTLET)
CEILING JOIST
(16 centers
shown)
2 X 4 FRAMING
(wide side down)
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing &
upside-down)
MOUNTING USING HANGER KIT (included)
Blower factory-shipped in straight-through
discharge position.
TYPICAL INSTALLATION
Blower factory-shipped in straight-through
discharge position.
ACCESS PANEL
ACCESS
PANEL SCREW
GRILLE NUT
(Install into
square holes in
housing)
MOUNTING
BRACKET
10 ROUND
DUCT
(OUTLET)
10 ROUND
DUCT (INTAKE)
HANGER
KIT NUT &
WASHER
HANGER
KIT BOLT
& WASHER
HANGER KIT
EYE-BOLT
HANGER
KIT CHAIN
8 TO 10 ROUND TRAN-
SITION
10 ROUND
DUCT
(INTAKE)
8 TO 10
ROUND
TRANSITION
MOUNTING (Existing Frame Construction)
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
10 ROUND DUCT
Factory-shipped unit installed in new construction.
Blower
factory-
shipped
in straight
through
discharge
position.
Mounting brackets factory-
shipped in position for
½ ceiling material.
ADDITIONAL
FRAMING
CEILING JOIST
(16 centers
shown)
10 ROUND
DUCT
MOUNTING SCREW
8 TO 10 ROUND TRAN-
SITION
EXTENSION
SPRING
Page 3
MODEL ILB3
WIRING PLATE POSITION
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
Wiring plate mounts to side or top of housing.
HORIZONTAL POWER
CABLE CONNECTION
VERTICAL
POWER
CABLE
CONNECTION
Blower and duct connector
in
straight through dis-
charge position.
(Factory shipped)
DUCT
CONNECTOR
DUCT
CONNECTOR
Blower and duct connector
in
right angle discharge
position.
BLOWER
BLOWER
Change
blower &
duct
connector
positions for
right angle
discharge.
DUCTING (Vertical blower discharge)
Typical ductwork connection to a ventilator converted to
right angle discharge.
ROOF CAP
ROUND
DUCT
WIRING
PLATE
WHITE
TO
WHITE
BLACK
TO
BLACK
TOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
12¼"
9
1
/
2
"
to
10
1
/
2
"
12¼"
1½"
to
2½"
MOUNTING OPTIONS
12¼"
1
1
/
8
"
MAX.
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
(
New construction)
12¼"
10
3
/
4
"
to
11
3
/
4
"
12¼"
¼-20 hex nuts secure mounting brackets to housing. Loosen and
re-tighten or remove and replace nuts as necessary for desired
mounting bracket position.
Mounting brackets flipped
over and mounted to outlet
sides of housing.
(Outlet parallel to joists.)
(
Existing construction)
Mounting brackets mounted
to outlet sides of housing.
(Outlet perpendicular to joists.)
(
New construction)
Mounting brackets flipped
over and mounted to top of
sides of housing.
(Outlet parallel to joists.)
(
New or existing construction)
12¼"
1
1
/
2"
to
2
1
/
2"
Mounting brackets flipped
over to give approx. 1
more clearance.
(Outlet parallel to joists.)
(
New construction)
Mounting brackets mounted
to top of sides of housing.
(Outlet parallel to joists.)
(
New or existing construction)
120 VAC
LINE IN
(from
range
hood)
WIRING