Braun Age Precision PRT 2000 Bruksanvisning

Braun Termometer Age Precision PRT 2000

Läs gratis den bruksanvisning för Braun Age Precision PRT 2000 (4 sidor) i kategorin Termometer. Guiden har ansetts hjälpsam av 33 personer och har ett genomsnittsbetyg på 4.0 stjärnor baserat på 7 recensioner. Har du en fråga om Braun Age Precision PRT 2000 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
English
Description
1. Measuring sensor 5. Large display with colour-coded indicator lights
2. Extra gentle exible tip 6. Battery compartment cover (back)
3. On/O button (side) 7. Protective cap
4. Age Precision™ button
Warnings and Precautions
•YourBraunDigitalThermometerisa3-in-1thermometersuitableforunderarm,oralorrectaluse.
Whichevermethodisused,itisrecommendedthatfor15minutespriortouse,avoideatingordrinking
anyliquids,exercising,takingshowersorbaths,orsmoking.
•Thisthermometerisintendedforhouseholduseonly.Thisproductisnotintendedtodiagnoseany
disease,butisausefulscreeningtoolfortemperature.Useofthisthermometerisnotintendedasa
substituteforconsultationwithyourphysician.
•TheAgePrecision™featureisnotintendedforpre-termbabiesorsmall-for-gestationalagebabies.The
AgePrecision™featureisnotintendedtointerprethypothermictemperatures.
•Pleaseconsultyourphysicianifthethermometershowselevatedtemperature.High,prolongedfever
requiresmedicalattention,especiallyforyoungchildren.
•Parents/guardiansshouldcallthephysicianuponnoticinganyuntowardsign(s)orsymptom(s).For
example,achildwhoexhibitsirritability,vomiting,diarrhea,dehydration,changesinappetiteor
activity,evenintheabsenceoffever,orwhoexhibitsalowtemperature,maystillneedtoreceive
medicalattention.Childrenwhoareonantibiotics,analgesics,orantipyreticsshouldnotbeassessed
solelyontemperaturereadingstodeterminetheseverityoftheirillness.
•TemperatureelevationasindicatedbyAgePrecision™maysignalaseriousillness,especiallyin
neonatesandinfants,oradultswhoareold,frail,haveaweakenedimmunesystem.Pleaseseek
professionaladviceimmediatelywhenthereisatemperatureelevationandifyouaretaking
temperaturefor:
-Neonatesandinfantsunder3months.Consultyourphysicianimmediatelyifthetemperature
exceeds37.4°Cor99.4°F.
-Patientsover60yearsofage.Fevermaybebluntedorabsentinelderlypatients.
- Patients having diabetes mellitus or a weakened immune system
(e.g.HIVpositive,cancerchemotherapy,chronicsteroidtreatment,splenectomy).
- Patients who are bedridden
(e.g.nursinghomepatient,stroke,chronicillness,recoveringfromsurgery).
-Atransplantpatient(e.g.liver,heart,lung,kidney).
•Donotallowchildrenunder12yearsofagetotaketheirtemperaturesunattended.
•Donotallowchildrentowalkorrunduringtemperaturetaking.
•Thisthermometercontainssmallpartsthatcanbeswallowedorproduceachokinghazardtochildren.
Alwayskeepthethermometeroutofchildren’sreach.
•Donotmodifythisequipmentwithoutauthorizationofthemanufacturer.
•ManufacturingdateisgivenbytheLOTnumberlocatedatthebackofthethermometer.Therstthree
(3)digitsrepresenttheJuliandatethattheproductwasmanufactured,andthenexttwo(2)digits
representthelasttwonumbersofthecalendaryeartheproductwasmanufactured.Thelastidentiers
arethelettersthatrepresentthemanufacturer.
•Anexample:LOT:11614FAMimpliesthisproducthasbeenmanufacturedonthe116thdayofthe
year 2014.
What is new about Braun Age Precision™ Thermometer?
•Clinicalresearchshowsthedenitionoffeverchangeswithage1.Forexample,whatisanormal
bodytemperatureina4yearold,mayberegardedasafeverinanewborn.Braun’sAgePrecision™
thermometerisanageadjustablethermometerwithapatentedFeverInsight®colour-codeddisplay.
Itusesmedicalguidelinestointerprettemperatureandtakestheguessworkoutofinterpreting
temperaturefortheentirefamily.
•Temperaturereadingsvarydependingonthesiteofmeasurement.Anoraltemperatureisgenerally
0.1°C higher than underarm (axillary) temperature and rectal temperature is generally 0.6°C higher than
underarm temperature.1,2
Braun’s Age Precision™ feature is optimized for underarm temperature taking.
•Temperaturereadingsvaryfrompersontoperson.Thebestmethodtodetermineyourownnormal
temperatureistousethethermometerwhenyouarefeelingwell.Recordyourreadingtwiceaday
(earlymorningandlateafternoon).Taketheaverageofthetwotemperatures.Thisisconsideredyour
normalbodytemperature.Anyvariationfromitmayindicatesomesortofillnessandyoushould
consult your physician.
Itisimportanttorememberfeverisasymptom,notadisease,andisjustoneofthemanypossiblesignsof
illness.Ifyourchildexhibitssignsofaseriousillness,contactyourphysician
How to Use Your Braun Age Precision™ Thermometer
3 Simple Steps:
1. Switch on the thermometer by pressing the On/O button
Youwillhearashortbeepanddisplaysegmentcheckwillbeperformed.Afterthesegmentcheck,last
temperaturereadingwillbedisplayedfor2seconds.Subsequently,theageiconsandagerangewill
cycle,untiltheAgePrecisionbuttonispressed.
2. Select the age by pressing the AgePrecision™ button
WhentheAgePrecision™buttonispressed,theagerangeiconswillstopcycling,andstopontheage
range icon that was showing when the button was pressed. Keep pressing the button until the desired
agesettingisdisplayed.Thethermometerhas3agesettings:
•0-3months
•3-36months
•36monthsuptoanadult
Aftertheageisselected,theagerangeiconremainssteadilylit.
Thedisplaywillshowthreedashedlinesandthethermometer
is ready to start the measurement.
3. Take the measurement by placing it on the measurement site.
Oncetemperatureriseisdetectedbythermometerinmeasurementmode,itwillbegintomeasure.
Ifthethermometerdoesn’tmeasureatemperaturerise,theageiconandthreedashedlineswillbe
shown until the thermometer automatically turns o.
Aftermeasurement(generally8secondsaftertemperaturechangeisdetected),theconrmation
beepindicatesthatanaccuratetemperaturemeasurementhasbeentaken:1longbeepfornormal
temperature,10shortbeepsforelevatedandhightemperature.Theresultwillbeshownonthe
display.InterpretthereadingwiththehelpofthecolourcodedFeverInSight®displaythatusesmedical
guidelinestointerprettemperaturebasedontheageofthepatients.
Note:Usershavetoshutdownthethermometerandstartupagaintotakeanothermeasurementand/or
changeagesetting.TheBraunAgePrecision™thermometerturnsoautomatically
20secondsafterthemeasurementorafter90secondswithoutmeasurement.
Reading the measurement with Fever InSight® Colour Coded Display
BraunAgePrecision™ThermometercomeswiththepatentedFeverInSight®displaythatoersacolour
indication along with the temperature readout and helps you better understand the temperature reading
basedonpatients’age.
- Green backlight indicates readingnormal
-Yellowbacklightindicateselevated temperature
-Redbacklightindicateshigh temperature
TheFeverInSight®colourcodeddisplayforinterpretingfeverhasbeendesignedforuseintheunderarm
mode only according to the table below.
SiteAge rangeGreen
Normal temperature
Yellow
Elevated temperature
Red
Hightemperature
Underarm
0-3 Months35.7 – 37.3 °C> 37.3 °C
3-36 Months35.3 – 37.4 °C37.5–38.4°C >38.4°C
36 Months-
adult 35.3 – 37.4 °C37.5 – 39.4 °C> 39.4 °C
Ifyouusethethermometerintheoralorrectalmodebyplacingitatthosesites,pleasedonotusethe
displaylightsprogrammedintothethermometerfordeterminingfever.Instead,refertotheoralandrectal
tablesrespectivelyasshownbelowtodetermineifyouhaveafever.
SiteAge range Normal temperatureElevated temperatureHigh temperature
Oral
0-3 Months35.8–37.4°C> 37.4 °C
3-36 Months35.4 – 37.6 °C37.7–38.5°C >38.5°C
36 Months
to Adult35.4 – 37.7 °C> 39.4 °C37.8-39.4°C
Rectal
0-3 Months36.3 – 37.9 °C> 37.9 °C
3-36 Months 35.9–38.1°C38.2–39.0°C> 39.0 °C
36 Months-
adult 35.9–38.2°C38.3–39.9°C> 39.9 °C
Note:Duetohumanphysiology,temperaturemeasurementstakenfromdierentsitesonthesame
personshowvariability.Forexample,rectalreadingstendtorunhigherthanoralaswellasunderarm
readingstakenfromthesameperson.
Tips for Measuring at Dierent Sites
Under-the-arm (axillary) use
Thismethodisusedforbabiesandyoungchildren.
1. Wipe the underarm with a dry towel.
2.Placetheprobetipunderthearmsothetipistouchingtheskinandpositionthepatient’sarmnextto
thepatient’sbody(Fig.1).
Withayoungchild,itissometimeshelpfultohugthechildtokeeptheirarmnexttotheirbody.This
ensures that the room air does not aect the reading.
3.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
4.Turnothethermometerandcleanasrecommendedbelow.
Fig.1Fig.2
Oral use
Thismethodissuitableforchildrenwhoareoldenoughtosafelykeepthethermometerinsidethemouth.
1.Itisimportanttoplacethetipofthethermometerwellunderthetongueoneithersidetogetagood,
accuratereading.Placesensortipinareasmarkedwith“√”underthetongue(Fig.2).Keeppatient’s
mouth closed and make him/her sit still to help ensure an accurate measurement.
2.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
3.Turnothethermometerandcleanasrecommendedbelow.
Rectal use
Commonlyusedforbabies,youngchildren,orwhenitisdiculttotakeanoralorunderarmtemperature.
1.Coverthethermometer’stipwithaprobecoverandlubricatewithawater-solublejellyforeasier
insertion.
Donotuseapetroleumjelly.Readthelabelofthelubricanttobesureyouareusingtherightkind.
2.Laythepatientonhis/herside.Ifthepatientisaninfant,theproperpositionforababyistolayonits
stomachwithlegshangingdown,eitheracrossyourkneesorattheedgeofabedorchangingtable.
Thispositionstheinfant’srectumforsafeandeasyinsertionofthethermometer.
3.Gentlyinsertthetipofthethermometer 1.3cmor1/2inchintotherectum.IfyouNO MORE THAN
detectresistance,stop.Holdthethermometerinplaceduringmeasurement.
4.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
5.Turnothethermometerandcleanasrecommendedbelow.
Memory
Whenthethermometeristurnedon,thedisplaywillshowatest,afterwhichthelastmeasured
temperaturewillbeshownforapproximately1second.Letter“M”willbedisplayednexttothe
temperature reading.
Changing the Temperature Scale
Withpowero,pressandholdtheOn/Obuttonforabout5secondsuntil“---“withasteady“°C”or
“°F”appearsonscreen.ReleaseandpresstheOn/Obuttonagaintoswitchfromthecurrentscaletothe
alternatescaleandrelease.Afterabout3secondstheunitisreadyfortakingtemperatureinthechosen
scale and the age range icons start to scroll.
Care and Cleaning
•Cleantheprobetipbywashingwithsoapandwarmwaterorbydisinfectingwithrubbingalcohol(70%
isopropyl alcohol).
•Wipedrywithsoftcloth.
•DO NOT BOIL OR CLEAN IN DISHWASHER.Thiswillcausethethermometertonolongerfunctionand
will void the warranty.
•Donotwashtheunitwithanythinnerorchemicalsolvent
•Storeyourthermometerinadrylocation,freefromdustandcontaminantsandawayfromdirect
sunlight
Replacing the Batteries
WhenthebatterysymbolonLCDdisplaytwinklescontinuallyreplace with new battery.
1.Insertcoinintoslot.RotatedooruntilslotislinedwithUNLOCKsymbol.
2.Replacebattery
3.RotatebatterydoortoLOCKEDposition.
Errors and Troubleshooting
Whenmeasuredtemperatureishigherthan42.9°C,LCDwilldisplay“Err°C”
andrelevantageicon.Redbacklightstaysonfor5seconds.
Whenambienttemperatureisoutofrange(seeProductSpecicationsbelow)
orothersystemerrorsoccursuchasshortorbrokencircuit,LCDwilldisplay“Err
toindicatesystemerror.Redbacklightstaysonfor5seconds.
Limited Two Year Warranty
Kazwarrantsthisproductagainstanydefectsthatareduetofaultymaterialorworkmanshipforaperiod
oftwoyearsfromtheoriginaldateofconsumerpurchaseorreceiptasagift.Thiswarrantyapplieswhen
usedfornormalhouseholduseinaccordancewiththeUseandCareManualandexcludesthebatteryand
damagetotheproductresultingfromaccidentormisuse.Thisproductisnotwarrantedwhenusedina
professionalenvironment.
InnoeventshallKazbeliableforanyspecial,incidental,indirectorconsequentialdamagesinconnection
withthepurchaseoruseofthisproductorcostsovertheoriginalcostofproduct.
Iftheproductshouldnotperformtospecicationswithinthewarrantyperiod,pleasecontactConsumer
Relationsat1-800-477-0457oremailatc[email protected]morwritetoKazUSAInc,Consumer
RelationsDepartment,250TurnpikeRoad,Southborough,MA01772.InCanada,youcancontactus
at510BronteStreetS,Milton,ON,L7T2X6,Canada.Kazreservestherighttoreplaceanonconforming
productwiththemostcomparableproductcurrentlyavailable.Thisproducthasaveyearminimum
expectedlifetime.
Product Specications
Displayedtemperaturerange:32.0°C-42.9°C(89.6°F-109.2°F)
Operatingambienttemperaturerange:10–40°C(50–104°F)
andrelativehumidityrangeof15%~95%
Displayresolution:0.1°Cor°F
AccuracyfordisplayedtemperaturerangeMaximumLaboratoryError
35°C–42°C(95.9°F–107.6°F):±0.1°C(±0.2°F)atanambientof23±5°C
outsidethisrange:±0.2°C/0.4°F(within32.0°C-42.9°C(89.6°F-109.2°F))
Batterylife:500timesmeasurementswithin2years
Servicelife:2000measurements
Storage/Transporttemperature-25-55±2°Cand15-95RH%±5%
and relative humidity
Ifthedeviceisnotusedwithinspeciedtemperatureandhumidityrangesthetechnicalaccuracyofthe
measurement cannot be guaranteed.
Explanation of symbols
TypeBFappliedparts Seeinstructionforuse
Operating temperature  Storagetemperature
Keep dry
IP22:Protectedagainstsolidforeignobjectsof12.5mmdiameterandgreater.Protectedagainstvertically
fallingwaterdropswhenthedeviceistiltedupto15degrees.
Thisthermometerisspeciedtooperateat1atmosphericpressureorataltitudeswithanatmospheric
pressure up to 1 atmospheric pressure (760-1060 hPa).
SeeInstructionforuseEquipmentwithtypeBFappliedparts
Subjecttochangewithoutnotice.
Thisapplianceconformstothefollowingstandards:
StandardReferenceEditionTitle:EN12470-3:2003Clinicalthermometers-Part3:Performanceofcompact
electrical thermometers (non-predictive and predictive) with maximum device.
EN60601-1:2006Medicalelectricalequipment–Part1:Generalrequirementsforbasicsafetyand
essentialperformance.
English
Français
GB
FR
Guidanceandmanufacturer’sdeclaration–electromagneticemissions
ThePRT2000equipmentisintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Emissions TestComplianceElectromagnetic environment – guidance
RFEmissions
CISPR11 Group 1
TheMEequipmentusesRFenergyonlyforit’sinter-
nalfunction.Therefore,itsRFemissionsareverylow
andarenotlikelytocauseanyinterferenceinnearby
electronic equipment.
RFEmissions
CISPR11 Class BComplies
HarmonicemissionsIEC
61000-3-2 Not Applicable
TheMEequipmentis
solely battery powered.
Voltageuctuations/
icker emissionsNot Applicable
Non-Life Support Equipment Separation Distance Calculation
(3Vrms / 3V/m compliance)
Ratedmaximumoutput
poweroftransmitter(W)
Separationdistanceaccordingtofrequencyoftransmitter(m)
150kHzto80MHzin
ISMbands
80MHzto800MHz800MHzto2.5GHz
d = [ 7 ] P
E1
0.01/0.120.23
0.1 /0.730.38
1/1.22.3
10 /7.33.8
100/1223
d = [
3,5] P
V
1
d = [3,5] P
E1
Guidance and manufacturer’s declaration – electromagnetic immunity
ThePRT2000isintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Immunity testIEC60601 test
level
Compliance
level
Electromagnetic environment
– guidance
Electrostatic discharge
(ESD)
IEC61000-4-2
±6kVContact
±8kVAir Complies
Floorsshouldbewood,concrete,
orceramictile.Ifoorsare
coveredwithsyntheticmaterial,
the relative humidity should be
atleast30%
RadiatedRF
IEC61000-4-3
3V/m80MHzto
2.5GHz Complies
Fieldstrengthsoutsidethe
shieldedlocationfromxedRF
transmitters,asdeterminedby
anelectromagneticsitesurvey,
shouldbelessthan3V/m.
Interferencemayoccurinthe
vicinityofequipmentmarked
withthefollowingsymbol:
Separationdistancecalculation
providedabove.Ifaknown
transmitterispresentthespecic
distance can be calculated using
the equations.
ConductedRF
IEC61000-4-6
3Vrms150kHzto
80MHz
Not Applicable
(no electrical
cabling)
Electricalfasttransient
IEC61000-4-4
±2kVpowerline
±1kVI/Olines Not Applicable
TheMEequipment
is solely battery powered.
Surge
IEC61000-4-5
±1kV
dierential
±2kVcommon
Not Applicable
Powerfrequency
magneticeld
IEC61000-4-8
3 A/mComplies
Powerfrequency
magneticeldsshouldbeat
levelscharacteristicofa
typical location in a typical
commercial or hospital
environment.
Voltagedips,short
interrupts and voltage
variations on power
supply input lines
IEC61000-4-11
>95%dip0.5
cycle
60%dip5cycles
70%dip25cycles
95%dip5sec.
Not Applicable
TheMEequipment
is solely battery
powered.
ENISO14971:2012Medicaldevices–Applicationofriskmanagementtomedicaldevices.
ENISO10993-1:2009Biologicalevaluationofmedicaldevices–Part1:EvaluationandTesting.
EN60601-1-2:2007Medicalelectricalequipment–part1-2:Generalrequirementsforbasicsafetyandes-
sentialperformance–Collateralstandard:electromagneticcompatibility–Requirementsandtests
EN980:2008Symbolsforuseinlabelingofmedicaldevices.
EN1041:2008Informationsuppliedbythemanufacturerofmedicaldevices.
EN60601-1-11:2010Medicalelectricalequipment--Part1-11:Generalrequirementsforbasicsafetyand
essentialperformance--Collateralstandard:Requirementsformedicalelectricalequipmentandmedical
electrical systems used in the home healthcare environment.
ThisproductconformstotheprovisionsoftheECdirective93/42/EEC.
MEDICALELECTRICALEQUIPMENTneedsspecialprecautionsregardingEMC.Fordetaileddescriptionof
EMCrequirementspleasecontactourConsumerRelationsDepartment.
PortableandmobileRFcommunicationsequipmentcanaectMEDICALELECTRICALEQUIPMENT.
Pleasedonotdisposeoftheproductinthehouseholdwasteattheendofitsusefullife.Disposal
can take place at your local retailer or at appropriate collection points provided in your country.
Toprotecttheenvironment,disposeofemptybatteriesatappropriatecollectionsitesaccordingto
national or local regulations.
1HerzogL,PhillipsSG.Addressingconcernsaboutfever.ClinPediatr(Phila)2011May;50(5):383-90.
2Sund-LevanderM,ForsbergC,WahrenLK.Normaloral,rectal,tympanicandaxillarybodytemperature
inadultmenandwomen:asystematicliteraturereview.ScandJCaringSci2002June;16(2):122-8.
Age Precision
Digital
Thermometer
PRT 2000
Age PrecisionMC
Thermomètre
numérique
Downloaded from www.vandenborre.be

Betygsätt denna manual

4.0/5 (7 Recensioner)

Produktspecifikationer

Varumärke: Braun
Kategori: Termometer
Modell: Age Precision PRT 2000
Färg på produkten: Blue, Grey
Vikt: - g
Bredd: 225 mm
Djup: 141 mm
Höjd: 30 mm
Typ av förpackning: Doos
Ethernet LAN: Ja
Snabbstartsguide: Ja
Inkluderar AC-adapter: Ja
Antal Ethernet LAN (RJ-45)-portar: 4
Antal USB-anslutningar: 1
USB-version: 2.0
Anslutning för nätadapter: Ja
Ethernet LAN, dataöverföringshastigheter: 10,100,1000 Mbit/s
Kabelteknik: 10/100/1000Base-T(X)
Nätverksstandard: IEEE 802.11b, IEEE 802.11g, IEEE 802.11n
Säkerhetsalgoritmer som stöds: 64-bit WEP, 128-bit WEP, 152-bit WEP, WDS, WPA, WPA-PSK, WPA2, WPA2-PSK
Typ av antenn: Extern
Antenner kvantitet: 3
Antennförstärkningsnivå (max): 5 dBi
Förvaringstemperatur: -40 - 70 °C
Användarmanual på CD-ROM: Ja
Firmware-uppgradering möjlig: Ja
Nätverksprotokoll som stöds: Dynamic IP, Static IP, PPPoE, PPTP(Dual Access), L2TP(Dual Access), BigPond
Webbaserad hantering: Ja
Stöder Mac-operativsystem: Ja
Förvaringsfuktighet: 5 - 90 procent
Återställningsknapp: Ja
Frekvensomfång: 2.4 - 2.4835 GHz
MAC-adressfiltrering: Ja
Ethernet WAN: Ja
Stöder Linux: Ja
Brandvägg: Ja
IP-adressfilter: Ja
DoS-attackförebyggande: Ja
Utström: 1.5 A
Spännande: 12 V
DHCP-server: Ja
Ethernet-gränssnittstyp: Gigabit Ethernet
Antennanslutning: RP-SMA
Universal Plug and Play (UPnP): Ja
Quality of Service (QoS): Ja
Auto MDI/MDI-X: Ja
DHCP-klient: Ja
Dataflödeshantering: Ja
DMZ-stöd: Ja
Full duplex: Ja
WPS-tryckknappssäkerhet: Ja
Löstagbara antenner: Ja
Drifttemperatur (TT): 0 - 40 °C
Relativ luftfuktighet i drift (VV): 10 - 90 procent
VPN-egenskaper: PPTP, L2TP, IPSec (ESP Head)
Filterbeskrivning: Domain
Överföringskraftsområde: 0 - 20 dBmW

Behöver du hjälp?

Om du behöver hjälp med Braun Age Precision PRT 2000 ställ en fråga nedan och andra användare kommer att svara dig