Crestron CLW-SWEX-P Bruksanvisning
Läs gratis den bruksanvisning för Crestron CLW-SWEX-P (2 sidor) i kategorin Växla. Guiden har ansetts hjälpsam av 69 personer och har ett genomsnittsbetyg på 3.7 stjärnor baserat på 35 recensioner. Har du en fråga om Crestron CLW-SWEX-P eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
CLW-SWEX-P
Cameo
®
 Wireless In-Wall Switch, 120 V
Operations & Installation Guide
Description
Crestron
®
 in-wall dimmers and switches are modeled after the popular, modern look of 
Cameo
®
 keypads. Available with adjustable button layouts and designer colors, the 
Cameo dimmers and switches are more versatile and affordable than previous 
generations. Like their cousin keypads, button caps can be swapped in the eld, making it 
easy to change engraving or color. And their streamlined look inspires the combination of 
in-wall lighting control with centralized lighting control—delivering the ultimate, entire 
home control solution.
Specications
Specications for the CLW-SWEX-P are listed in the following table.
CLW-SWEX-P Specications
Installation
WARNING:  To avoid re, shock, or death, turn off power at circuit breaker or fuse and 
test that power is off before wiring! 
WARNING:  New installations should be checked for short circuits prior to installing a 
CLW-SWEX-P switch. With the power off, close the circuit and restore power. If the loads 
do not work or a breaker trips, check and correct the wiring or xture (if necessary). Install 
the switch only when the short is no longer present. The warranty is void if the switch is 
installed and operated with a shorted load.
NOTES:  Observe the following points.
•  This product should be installed and used in accordance with appropriate electrical 
codes and regulations.
•  This product should be installed by a qualied electrician.
NOTE:  Before using the CLW-SWEX-P, ensure the device is using the latest rmware. 
Check for the latest rmware for the CLW-SWEX-P at www.crestron.com/rmware. 
Firmware is loaded onto the device using Crestron Toolbox™.
1.  Turn power off at the circuit breaker.
2.  Wire the device as shown in the following diagrams.
Wire the CLW-SWEX-P
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) or 
scan the QR code to the right for additional information and the latest 
rmware updates.
*  A neutral wire is required for normal operation.
Important Notes (Read Before Installation)
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO 
OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE OR A 
TRANSFORMER-SUPPLIED APPLIANCE.
ATTENTION: GRADATEURS COMMANDANT UN BALLAST-AFIN DE RÉDUIRE LE 
RISQUE DE SURCHAUFFE ET LA POSSIBILITÉ D’ENDOMMAGEMENT À D’AUTRES 
MATÉRIELS, NE PAS INSTALLER POUR COMMANDER UNE PRISE OU UN APPAREIL 
ALIMENTÉ PAR UN TRANSFORMATEUR.
•  Neutral: The CLW-SWEX-P requires a neutral connection to operate.
•  Codes: Install in accordance with all local and national electrical codes.
•  Wiring: Use copper wire only that are rated for at least 75°C.
•  Lamp Type: For use with permanently installed incandescent, magnetic low voltage, 
tungsten-halogen, or CFL only.
•  Temperature: For use where temperatures are between 32° to 104°F (0° to 40°C).
•  Electrical Boxes: Devices mount in standard electrical boxes. For easy installation, 
use 3 1/2 in (89 mm) deep electrical boxes. Several devices can be installed in one 
electrical box (multigang). For a smooth appearance, one-piece multigang 
faceplates (not supplied) can be installed. When installing into a multigang box, do 
not fully tighten the devices to the box until the faceplate has been aligned.
•  Switches: Mechanical 3- or 4-way switches do not work with the CLW-SWEX-P 
series switchers.
•  Spacing: If mounting one device above another, leave at least 4 1/2 in (115 mm) 
vertical space between them.
•  Low Voltage Applications: Operation of a low voltage circuit with all lamps 
inoperative or removed may result in current ow in excess of normal levels. To 
avoid transformer overheating and premature transformer failure, Crestron 
recommends the following:
>  Do not operate low voltage circuits without operative lamps in place.
>  Replace burned-out lamps as quickly as possible.
>  Use transformers that incorporate thermal protection or fuse transformer 
primary windings to prevent transformer failure due to overcurrent.
Make Connections to the CLW-SWEX-P
NOTE:  Refer to the CLW-SLVU-P Installation Guide (Doc. 7364) for wiring details.
3.  Push all power wires back into the electrical box and fasten the device to the electrical 
box with the provided screws.
4.  Attach the decorative faceplate.
5.  Ensure all buttons actuate without sticking.
6.  Restore power at the circuit breaker.
YesNo
Do not insert the wires behind the screw head. 
Insert the wires into the wire entry holes.
Changing Button Assemblies
The button assembly can be removed and replaced with other button assemblies. To 
change a button assembly, perform the following procedure.
1.  Remove the button assembly by squeezing the sides of the bezel near the bezel 
snaps, as shown in the following diagram.
Squeeze at the arrow 
points and pull to 
remove the button 
assembly.
NOTE:  When the button assembly is removed, power to the unit and load is 
removed automatically.
2.  Remove the button(s) from the front of the button assembly.
Gently spread the 
frame apart to remove 
the buttons.
3.  Insert the new buttons through the front of the bezel and snap them into place. 
Ensure that the LED is on the left side.
4.  Attach the button assembly to the device. Ensure that the LED is on the left side.
Gently spread the 
frame apart to insert 
the buttons.
Operation
NOTE:  The device may be warm to the touch during operation. This is normal.
Basic Operation
Operation described in this guide assumes the CLW-SWEX-P is operating in Local mode 
(without the use of a control system). The CLW-SWEX-P can also operate in Remote 
mode in which button behavior is dictated entirely by the control system program. The 
CLW-SWEX-P is shipped with a rocker switch already installed. In this conguration, the 
unit will function as shown below.
The LED is bright when the 
load is on and dim when 
the load is off (night light).
Tap to turn on the 
load.
Tap to turn off the 
load.
Default Button Functions
The gures below illustrate the default functions available for each physical button 
conguration and tap action sequence.
Button Press
Double Button Press (Press Twice within 1/2 Second)
Master and Slave Operation
For more information on master and slave operation, refer to the CLW-SLVU-P Installation 
Guide (Doc. 7364).
1.  Delayed off can be added via control system programming.
2. Fast off functionality is only performed if a delay has been added via control system programming.
On
On
—
—
Off
1
Fast
Off
2
Off
1
Fast
Off
2
Black
Black
White
Line
120 V~
Load
White
To one or more 
CLW-SLVU-P 
(Optional, sold 
separately)
SPECIFICATION  DETAILS 
Power Requirements  120 Vac, 60 Hz, line power 
Load Types  CFL, Electronic Ballasts, Incandescent, Magnetic 
Low Voltage, Tungsten-Halogen 
Load Ratings 
Minimum Load  25 W 
Incandescent/Tungsten 
Halogen/Magnetic 
Ballasts 
1000 VA/W 
Electronic Ballasts/CFL  600 VA 
Motor  1/2 HP 
Environmental 
Temperature  32° to 104°F (0° to 40°C) 
Humidity  10% to 90% RH (non-condensing) 
Connections 
Hot  (1) 14-12 AWG, screw terminal, brass, line power 
input 
Remote  (1) 14-12 AWG, screw terminal, blue, remote 
Load  (1) 14-12 AWG, screw terminal, red, load output 
Neutral  (1) 14-12 AWG, screw terminal, silver, neutral* 
Ground  (1) 18 AWG Class 1 ying lead, green, ground 
(wire nut included) 
Maximum Number of 
Remote CLW-SLVU-P Units 
9 
Produktspecifikationer
| Varumärke: | Crestron | 
| Kategori: | Växla | 
| Modell: | CLW-SWEX-P | 
Behöver du hjälp?
Om du behöver hjälp med Crestron CLW-SWEX-P ställ en fråga nedan och andra användare kommer att svara dig
Växla Crestron Manualer
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         25 September 2024
                        
                    
                                                            
                        
                         24 September 2024
                        
                    
                                                            
                        
                         21 September 2024
                        
                    
                                                            
                        
                         21 September 2024
                        
                    
                                                            
                        
                         21 September 2024
                        
                    
                                                            
                        
                         21 September 2024
                        
                    
                                                            
                        
                         20 September 2024
                        
                    
                                                            
                        
                         20 September 2024
                        
                    
                                                            Växla Manualer
- Fibaro
- LevelOne
- Mercury
- IB Connect
- Trendnet
- Fantini Cosmi
- Tripp Lite
- Suevia
- Inverto
- ZyXEL
- Ansmann
- DEHN
- Atlona
- Panasonic
- Goobay
Nyaste Växla Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025