    Läs gratis den bruksanvisning för Crestron GLS-REMOTE-ODT/OIR (2 sidor) i kategorin Fjärrkontroll. Guiden har ansetts hjälpsam av 30 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 15.5 recensioner. Har du en fråga om Crestron GLS-REMOTE-ODT/OIR eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
GLS-REMOTE-ODT/OIR
IR Remote for GLS Occupancy Sensors
Operations Guide
Description
The Crestron® GLS-REMOTE-ODT/OIR is a compact IR 
wireless remote designed specically for setting up and 
commissioning a GLS-ODT-C-CN, GLS-ODT-C-NS, 
GLS-OIR-C-CN, or GLS-OIR-C-NS. The 
GLS-REMOTE-ODT/OIR provides buttons for 
programming and setting up the sensor without the 
need for a laptop computer or ladder. The 
GLS-REMOTE-ODT/OIR operates on two AAA batteries 
(included).
GLS-REMOTE-ODT/OIR Physical View
2. Congure the Sensor
After entering OCC Setup mode or VAC  mode, the sensor can be congured.Setup 
Additional Resources
Visit the product page on the 
Crestron website 
(www.crestron.com) for additional 
information and the latest rmware 
updates.
GLS-REMOTE-ODT/OIR 
OCC
SETUP
VAC
SETUP
EXIT
SETUP
30s 2m 5m
10m 15m 30m
DISABLE
DISABLE
ENABLE
ENABLE
US
OFF
US
LOW
US
MED
US
HIGH
PIR
OFF
PIR
LOW
PIR
MED
PIR
HIGH
B
ONLY
A
ONLY
A+B
1234
RESET
FORCE
VAC
SET
ID
1. Enter a Setup Mode
During operation of the remote, the sensor will emit one 
short beep for a successful entry and one short beep 
followed by long beep for an unsuccessful entry. The 
sensor will emit two short beeps when a setup mode is 
exited.
To enter a setup mode, press and hold the OCC SETUP 
or VAC SETUP button for 3 seconds. To exit either setup 
mode  press the  button. ,EXIT SETUP 
Setup Mode Table
COMMAND  DESCRIPTION 
OCC SETUP  OCC Setup mode allows the user 
to configure the sensitivity of the 
sensor when it is in an occupied 
state. 
Press and hold for 3 seconds to 
place the sensor into OCC Setup 
mode. 
VAC SETUP  VAC Setup mode allows the user to 
configure the sensitivity of the 
sensor when it is in a vacant state.  
Press and hold for 3 seconds to 
place the sensor into VAC Setup 
mode. 
While in VAC Setup mode, the 
sensor beeps to indicate that 
motion is detected. 
EXIT SETUP  Press to exit the active setup mode 
and return the sensor to normal 
operation. 
The sensor exits the active setup 
mode if no buttons are pressed on 
the remote for 5 minutes. 
COMMAND  DESCRIPTION 
TIMEOUT 
(30s, 2m, 5m, 10m, 
15m, 30m) 
SHORT TIMEOUT 
(ENABLE / DISABLE) 
US 
(A+B, A ONLY, 
B ONLY) 
These buttons set the time that the sensor must not see any motion before going to the 
vacant state. Timeout settings may be applied in OCC Setup or VAC Setup modes.  
These buttons enable or disable Short Timeout mode. Short Timeout mode limits the 
timeout to 60 seconds for the rst 90 seconds of occupancy after which the normal timeout 
applies. Short timeout settings may be applied in OCC Setup or VAC Setup modes. 
Th enable or disable some or all of the ultrasonic (US) sensors. The A and B ese buttons 
sensor banks are labeled under the cover of the sensor. If the sensor is not accessible, the 
A sensor bank is on the same side as the red LED and the B sensor bank is on the same 
side as the green LED. US settings may be applied in OCC Setup or VAC Setup modes. 
•A+B enables both banks of the ultrasonic sensors.
•A ONLY enables bank A and disables bank B.
•B ONLY enables bank B and disables bank A.
LED 
(ENABLE, DISABLE) 
SENSITIVITY 
(PIR HIGH, 
PIR MED, PIR LOW / 
PIR OFF) 
SENSITIVITY 
(US HIGH, US MED, 
US LOW, US OFF) 
SET ID 
Press these buttons to enable or disable the LEDs during normal operation. The green LED 
is for US detection and the red LED is for PIR detection. The LEDs are always enabled 
during a setup mode. LED settings may be applied while in OCC Setup or VAC Setup 
mode. 
When in OCC Setup mode, these buttons set the sensitivity of the passive infrared (PIR) 
sensor while the room is occupied. When in VAC Setup mode, the set the sensitivity of y 
the PIR sensor while the room is vacant. Settings for PIR LOW, PIR MED, or PIR HIGH 
indicate the sensitivity to motion. PIR OFF disables the PIR sensor regardless of which 
state the sensor is in. 
Refer to the “Detection Range” section in the sensor’s installation guide at 
www.crestron.com/manuals for more information on sensitivity. 
When in OCC Setup mode, th the sensitivity of the US sensor while the ese buttons set 
room is occupied. When in VAC Setup mode, th the sensitivity of the US sensor while ey set 
the room is vacant. Settings for US LOW, US MED, or US HIGH indicate sensitivity to 
motion. US OFF disables the ultrasonic sensors regardless of the sensor state. 
Refer to the “Detection Range” section in the sensor’s installation guide for more 
information on sensitivity. 
This button sets or changes the Net ID of the sensor. 
1. Press and hold the   button for 3 seconds. The sensor emits 3 short beeps SET ID
to indicate that it is ready for Net ID entry.
2. Enter the Net ID of the sensor using the numeric keypad on the remote. The 
sensor emits 1 short beep for each number entry.
3. Press   to conrm the entry. The sensor emits one long beep to indicateSET ID
successful Net ID entry and three short beeps to indicate failed entry.
RESET  Hold this button for 3 seconds to reset the sensor back to its factory default settings. The 
Net ID is not changed during device reset. The factory settings are listed below: 
•Remote Timeout: 0 minutes
•Local Timeout: 5 minutes
•Short Timeout: Disabled
•US: A+B enabled
•LED: Enabled
•Sensitivity: PIR medium and US medium
FORCE VAC  Hold this button for 3 seconds to force the sensor to enter the vacant state. The sensor 
ignores triggers for 5 seconds and then reverts to normal operation. 
CUSTOM 
(1, 2, 3, 4) 
These buttons are reserved for future custom programming. 
Produktspecifikationer
| Varumärke: | Crestron | 
| Kategori: | Fjärrkontroll | 
| Modell: | GLS-REMOTE-ODT/OIR | 
Behöver du hjälp?
Om du behöver hjälp med Crestron GLS-REMOTE-ODT/OIR ställ en fråga nedan och andra användare kommer att svara dig
Fjärrkontroll Crestron Manualer
                        
                         10 September 2024
                        
                    
                                                            
                        
                         10 September 2024
                        
                    
                                                            
                        
                         9 September 2024
                        
                    
                                                            
                        
                         8 September 2024
                        
                    
                                                            
                        
                         8 September 2024
                        
                    
                                                            
                        
                         8 September 2024
                        
                    
                                                            
                        
                         8 September 2024
                        
                    
                                                            
                        
                         8 September 2024
                        
                    
                                                            Fjärrkontroll Manualer
- NAD
- Lutron
- Milwaukee
- KPN
- Bang Olufsen
- Audio-Technica
- Engel Axil
- JL Audio
- Fibaro
- Waeco
- CME
- Syrp
- Autel
- Maginon
- Asustor
Nyaste Fjärrkontroll Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         4 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         31 Mars 2025
                        
                    
                                                            
                        
                         31 Mars 2025
                        
                    
                                                            
                        
                         30 Mars 2025