CyberPower RELAYIO600 Bruksanvisning


Läs gratis den bruksanvisning för CyberPower RELAYIO600 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 11 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 6 recensioner. Har du en fråga om CyberPower RELAYIO600 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
Rela
R
Quic
CyberPower Systems (US
4241 12th Avenue East S
Phone: 877-297-6937
Fax: 952-403-0009
www.CPSww.com
ay Control
Card
RELAYIO6
00
ck Reference Guide
SA), Inc.
uite 400 Shakopee, MN 55379
d
K01-0000427-00
Overview
The CyberPower Relay
solution for UPS status m
relays. In addition, the
R
UPS shutdown
in bat
CyberPower Online UPS
s
Installation G
Notice: The UPS can rem
1. Remove the
two retai
remove the cover.
2.
Install the CyberPowe
3. Re-
install and tighten
Technical Spe
Electrical
External S/D Voltage
Power Dissipation
Physical
Dimensions (HxWxD
Weight
Environmental
Operating Temperatu
Operating Humidity
Control Card (
RELAYIO600
monitoring and local device co
ELAYIO600
provides
1 input co
ttery mode
.
This card is
system
s with an
expansion po
uide
ain on when installing the
REL
ining screws of the expansion
er
RELAYIO600 card
into the ex
the retaining screws.
ecifications
RELAYIO600
e
7.5 -
12
1.35W M
(Default 12V
D)
43 x 67 x 1
55
1.7 x 2.64 x
6
88.6 g / 3.1
ure
0 - 40
32 - 104
0 to 95%
) offers users a
ntrol
via 5 output
ontact to perform
compatible with
ort.
LAYIO600 card
.
port cover then
xpansion port.
V
Max
input)
5
.7 mm
6.13
in
13 oz
%
Internal Circuit-DB9
I/O Pinout Definition-DB9
PIN
Assignment
Function I/O Jumper
PIN 1 UPS FAIL O/P JP1
PIN 2 SUMMARY ALARM O/P JP2
PIN 3 GND (Common for PIN 4)
Power GND N/A
PIN 4 REMOTE SHUTDOWN Power + Vcc
N/A
PIN 5 COMMON (For Relays) O/P N/A
PIN 6 BYPASS / UPS OFF O/P N/A
PIN 7 BATTERY LOW O/P JP3
PIN 8 UPS ON O/P N/A
PIN 9 POWER FAIL O/P JP4
Note1: Relay contact PIN 1/2/7/9 can be configured as Normally Open (NO)
or Normally Closed (NC).
Note2: Please see the Function Description section for details on jumper
position settings.
Internal Circuit-Terminal Block
I/O Pinout Definition-Terminal Block
Terminal
Assignment
Function I/O Jumper
T1 REMOTE SHUTDOWN Power + Vcc
N/A
T2 GND (Common for PIN 4)
Power GND N/A
T3 SUMMARY ALARM O/P JP2
T4 BYPASS / UPS OFF O/P N/A
T5 BATTERY LOW O/P JP3
T6 POWER FAIL O/P JP4
T7 UPS ON O/P N/A
T8 UPS FAIL O/P JP1
T9 COMMON (For Relays) O/P N/A
T10 COMMON (For Relays) O/P N/A
Note1: Relay contact T3/5/6/8 can be configured as Normally Open (NO) or
Normally Closed (NC).
Note2: Please see the Function Description section for details on jumper
position settings.


Produktspecifikationer

Varumärke: CyberPower
Kategori: Inte kategoriserad
Modell: RELAYIO600
Färg på produkten: Black, White
Vikt: - g
Bredd: 171.45 mm
Djup: 73 mm
Höjd: 171.45 mm
Anslutningsteknik: Bedraad
Genomsnittlig effekt: 125 W
Equalizerinställningar: Nee
Rekommenderad användning: Universeel
Impedans: 8 Ohm
Lämplig för utomhusbruk: Ja
Ljudutgångskanaler: 1.0 kanalen
Högtalarplacering: Inbouw in de muur/plafond
Antal förare: 1
Bashögtalare: Ja
Frekvensomfång: 58 - 22000 Hz
Känslighet: 90 dB
Förstärkare: Nee
Diameter woofer: 5.25 "
Antal basförare: 1
Diameter högtonenhögtalare: 1 "
Antal diskantdrivrutiner: 1
Tweeter: Ja

Behöver du hjälp?

Om du behöver hjälp med CyberPower RELAYIO600 ställ en fråga nedan och andra användare kommer att svara dig