Delta Dore Tyxia 611 Bruksanvisning
Delta Dore
Lättnad
Tyxia 611
Läs gratis den bruksanvisning för Delta Dore Tyxia 611 (1 sidor) i kategorin Lättnad. Guiden har ansetts hjälpsam av 12 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 6.5 recensioner. Har du en fråga om Delta Dore Tyxia 611 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/1

The TYXIA 611 pack enables
you to create a two-way lighng
without an exisng switch.
Recommendaons
IMPORTANT: the control wires are not
insulated from the mains power supply.
All connected equipment must be marked CE
and meet the requirements of the low voltage
devices as well as assembly recommendaons.
Local control wires can be extended up to 10
m (separate from the 230 V).
10A circuit breaker required.
Step 1 - Install your products
230V~
OFF
You can install the lighng receiver in a flush-mounted
box, behind a switch or control push-buon
(automac detecon on use) or behind a ceiling.
1.1 Connecon instrucons for terminals 1 2 3 4.
Strip the wires while respecng the strip length specified on the product.
1.1.1 Solid wires 1.1.2 Stranded wires
Push the wire fully
into the terminal.
Removal recommendaons
- Switch off the power supply.
- Use the tool supplied or a 2.5 mm screwdriver
to press the buon of the front terminal before
removing the wire. 2
1
1.2 Connecon instrucons for IN1 - COM - IN2 terminals
Use the wires supplied.
Push the wire fully into the terminal.
1.3 TYXIA 5610 connecon
Connect:
The light to terminals 3 and 4.
The switch to the IN1 -
COM terminals (input 1).
The 230 V power supply to terminals 1
and 2.
Switch the installaon power back on to
connue with the associaon operaon.
1.4 TYXIA 2310 installaon
This unit must not be placed on a metal surface.
Configuraon buons
Step 2 - Determine the operang mode of the TYXIA 2310
The operang mode of the TYXIA 2310 is, by default, mode A, i.e. for control-
ling 2 ON/OFF lighng channels.
IMPORTANT: If you approve this selecon, go directly to step 3,
'Associate your products'.
Otherwise, determine the operang mode suited to your installaon.
Mode B: Scenario mode to simultaneously control different receivers.
Mode C: Dimmer mode to control a dimmer lighng channel.
Open the unit.
Press the T2 buon several mes to select
your desired operang mode.
...... ...
EXIT
1
2
ON/OFF
ON/OFF
... ... ...
Mode A Mode B Mode C
The LED fl ashes
once
The LED fl ashes
twice
The LED fl ashes
three mes
Step 3 - Associate your products
❶Set the TYXIA 5610 receiver to associaon
standby mode. Press and hold the buon for 3
seconds unl the LED flashes, release.
❷ On the TYXIA 2310 emiers, send the
associaon order: Mode A or B: Press the
buon of the channel you want to associate
for 3 seconds (1 or 2).
Mode C: Press the 1 and 2 buons
at the same me and hold for 3 seconds.
❸ When the receiver LED has stopped flashing.
The products are now associated.
Number of associated emiers: 16 maximum
Troubleshoong
Summary of funcons accessible using the receiver buon
3’’
A
>10’’ 20’’>
C
>
B
Associaon/
Configuraon
Removing an
associaon
Removing
all associaons
Press and hold the buon for x seconds
AAssociaon/Configuraon
Press the receiver buon for 3 seconds unl the LED flashes, release.
BRemove an associaon
On the TYXIA 5610 receiver:
Press the receiver buon for 10 seconds unl the LED flashes rapidly, release.
On the TYXIA 2310 emier:
Mode A or B: Press the buon of the channel you want to delete for 3 seconds
(1 or 2).
Mode C: Press the 1 and 2 buons at the same me and hold for 3 seconds.
CRemove all associaons
Press the receiver's buon for 20 seconds.
Press and hold unl the LED switches off aer the rapid flashing phase, release.
The receiver has no wireless connecon.
The receiver locks in off mode
When an overload is detected, the product locks in off mode for 30 seconds be-
fore authorising a new acvaon. The LED flashes rapidly throughout this phase.
To exit the receiver from this secure mode, replace the bulb connected by a bulb
with lower power (refer to compability table).
You wish to change the operang mode of a product which has already been
associated. - You must first delete any associaon.
Replacing the baeries
Red Red Red
2s
The red LED flashes each me you press = Baery fault
Compability
① 230 V halogen or 230 V incandescent bulbs.
② 230V energy-saving compact fl uorescent bulbs.
③ 230V LED bulbs.
④ Very low voltage 12V halogen or LED bulbs with AC or DC electronic
transformer.
⑤Very low voltage 12V halogen bulbs with ferromagne c or toroidal transformer.
⑥Fluorescent tube.
200 W 100 W 100 W100 W100 W
LEDLED
150 W 100 W
M
Hi-Fi
230 V~ 50 Hz
2
1
230 V~
1
IN1
COM
TYXIA
5610
1 2 3 4
230V~
200W max
1234
Standby 0.06W
230 V~ 0.6 VA
IN1
CO M
IN1
CO M
ON
OFF
ON
OFF
230V~
µ
N S1NL
2
7mm 0,5 mm
KY31A02
123 4
230V
EN
Technical characteriscs
TYXIA 5610
- Power supply 230 V~ 0.6 VA
- Class II insulaon
Stand-by consumpon: 0.06 W
- Storage temperature: -10 °C / +70 °C
- Operang temperature: -10 °C / +40 °C
- IP 40 (flush mounng box)
- Dimensions: 41 x 36 x 14.5 mm
- X3D wireless remote control device:
868.7 MHz to 869.2 MHz
- Maximum wireless power < 10 mW Category 2 receiver
TYXIA 2310
- CR 2430 lithium baery power supply (included),
Baery life 10 years depending on use
- Storage temperature: -10 °C / +70 °C
- Operang temperature: -10 °C / +40 °C
- IP 40 - IK 04
- Dimensions: 84 x 84 x 13 mm
- X3D wireless remote control device:
868.7 MHz to 869.2 MHz
- Maximum wireless power < 10 mW Category 2 receiver
EN Wireless two-way pack
Use an electrically
isolated tool to per-
form the acons on
the receiver configu-
raon buon.
TYXIA
Switch off the installaon
power supply.
Do not strip the wires when they are
connected to the product as you
could damage the internal connector.
1 2 3 4
TYXIA
5610
TYXIA
5610
... ... ...
> 3s
µ
N S1NL
µ
N S1NL
1 2 3 4
TYXIA
5610
OK
OFF
µ
N S1NL
1
2
>3s
>3s
1
2
Removal recommendaons
Turn the wire while pulling on it.
1
2
123 4
TYXIA 2310
TYXIA 2310
TYXIA 5610
On / Off
On / Off
Alim. 230 V
230 V
200 W maxi.
TYXIA 611 pack
Using the tool
supplied or a 2.5
mm screwdriver,
press the terminal
buon then insert
the wire.
Important : If you have selected opera ng mode B (scenario
control), set each item to the required state (e.g. shu ers
lowered, ligh ng off ) before moving on to stage 1.
Produktspecifikationer
Varumärke: | Delta Dore |
Kategori: | Lättnad |
Modell: | Tyxia 611 |
Behöver du hjälp?
Om du behöver hjälp med Delta Dore Tyxia 611 ställ en fråga nedan och andra användare kommer att svara dig
Lättnad Delta Dore Manualer
4 September 2024
1 September 2024
31 Augusti 2024
31 Augusti 2024
29 Augusti 2024
29 Augusti 2024
28 Augusti 2024
27 Augusti 2024
26 Augusti 2024
Lättnad Manualer
- GP
- Wiesenfield
- CAT
- Lutec
- Enlite
- Toolcraft
- Fotodiox
- 9.solutions
- Cineo
- Razer
- Pontec
- Canarm
- TP Link
- Monacor
- Normann
Nyaste Lättnad Manualer
9 April 2025
9 April 2025
9 April 2025
8 April 2025
8 April 2025
8 April 2025
7 April 2025
5 April 2025
5 April 2025
5 April 2025