Elan Dombard 84320 Bruksanvisning

Elan Lättnad Dombard 84320

Läs gratis den bruksanvisning för Elan Dombard 84320 (8 sidor) i kategorin Lättnad. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 9 recensioner. Har du en fråga om Elan Dombard 84320 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/8
For warranty informaon please visit: kichler.com/warranty
1) Remove mounng pan[E] from main body[B] by
unscrewing three (3) countersunk mounng screws[G]
from side of main body. Retain screws for re-aaching
main body to mounng pan.
2) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in mounng
pan[E]. Thread mounng screws[F] into threaded holes
of mounng strap. Mounng screws should be threaded
the side of mounng strap opposite the outlet box[C].
Fixture Diagram
Parts List
Cauons
CAUTION RISK OF SHOCK
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
DIMMING:
This LED xture is compable with most standard
incandescent dimmers, LED dimmers, and electronic low
voltage dimmers.
For opmal performance, an electronic low voltage dimmer
should be used.
See kichler.com/dimming for a list of compable dimmers.
CLEANING:
• Always be certain that electric current is turned o before
cleaning.
• Only a so damp cloth should be used. Harsh cleaning
products may damage the nish.
Installaon Instrucons
[A] Mounting
Strap
[B] Main Body
[C] Outlet Box
[D] Strap
Mounting
Screw
[E] Mounting
Pan
[F] Mounting
Screw
[G] Countersunk
Mounting
Screw
3) Aach mounng strap to outlet box using the [A] [C]
strap mounng screws . Mounng strap can be [D]
adjusted to suit posion of xture.
4) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
5) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.) Neutral Wire
6) Raise mounng pan to ceiling, carefully passing over [E]
heads of mounng screws parally threaded into [F]
mounng strap.
7) Rotate the mounng pan to secure and ghten mounng
screws[F] up against mounng pan to secure pan to
ceiling. Mounng screws should be ghtened in the
keyholes as shown:
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Installaon Instrucons (connued)
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause
undesired operaon.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instrucons, may cause harmful interference to radio communicaons. However, there is
no guarantee that interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television recepon, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separaon between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Informaon:
IS-84320-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
REV 22-APR-2021
8) Raise main body[B] up over mounng pan , carefully [E]
aligning the mounng screw holes on the side of the
body with the holes on the side of the mounng pan.
9) Secure main body to mounng pan using countersunk
mounng screws[G] previously removed from main
body.