Etekcity Lasergrip 1080 Bruksanvisning
                    Etekcity
                    
                    Termometer
                    
                    Lasergrip 1080
                
                                
    Läs gratis den bruksanvisning för Etekcity Lasergrip 1080 (2 sidor) i kategorin Termometer. Guiden har ansetts hjälpsam av 28 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 14.5 recensioner. Har du en fråga om Etekcity Lasergrip 1080 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
Thank you for purchasing the Lasergrip 1080 Infrared Thermometer by 
Etekcity. This easy-to-use device lets you conveniently and accurately 
measure surface temperatures from a distance without the need of any 
direct contact. Should you have any questions or concerns, feel free to 
contact our helpful customer support team toll-free at 855.686.3835 or 
by email at support@etekcity.com.
NOTE: The Lasergrip cannot measure the temperature of objects behind 
glass. Inaccuracy may also occur when exposed to steam, dust or any 
other contaminants in the air.
NOTE: The Lasergrip LCD will display ‘OH’ when the measured 
temperature is above the measurable range, and will display ‘OL’ when the 
measured temperature is below the measurable range.
NOTE: The Lasergrip cannot measure the 
temperature of objects behind glass. Inaccuracy 
may also occur when exposed to steam, dust or 
any other contaminants in the air.
WARNING: THIS DEVICE PRODUCES   LASER RADIATION. USE CLASS 2
EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. DO NOT 
LOOK INTO DIRECT OR REFLECTED LASER-LIGHT BEAM OR VIEW BEAM 
WITH OPTICAL INSTRUMENTS. DO NOT AIM LASER-LIGHT AT ANOTHER 
PERSON OR ANIMAL. LASER RADIATION MAY DAMAGE YOUR EYE. DO 
NOT DISASSEMBLE THE DEVICE.
IMPORTANT: Read all of the instructions in this manual. 
Failure to comply with the instructions in this manual or use 
of the device, in ways other than the ones mentioned in this 
manual, may result in hazardous radiation exposure.
Safety Use & Care
Features
Specications
Operation
Function Diagram
•  DO NOT point the laser-light at another person or animal.
•  DO NOT attempt to point laser-light at an aircraft.
• Avoid direct/indirect eye contact with the laser-beam. Laser radiation 
may cause eye damage.
•  DO NOT view the beam with optical instruments. 
• In the vicinity of use, make any bystanders aware of the dangers of 
looking directly into the laser beam. 
•  DO NOT allow children to operate the device.
• Use a 9V battery when replacing the battery within the device. Make 
sure to insert the battery in accordance with the correct polarities.
•  ALWAYS remove the batteries when cleaning the device.
•  DO NOT use leaking batteries or dispose old batteries in fire. 
• Remove battery for storage if the device is not being used for a 
prolonged period of time.
•  DO NOT disassemble the device or tamper with internal components. 
Doing so will void any warranty.
•  DO NOT touch the lens or wipe it using anything other than a soft 
cloth or cotton swab.
• Laser guided targeting for aiming precision
• Narrow distance-spot ratio for accurate results at greater distances
• Safely measure hazardous or inaccessible objects
• Standard 9V battery powers up to 12 hours of cumulative use
• Auto-off after 15 seconds of inactivity
Measurement Range:  -58°F ~ 1022°F (-50°C ~ 550°C)
Accuracy: ±2% / ±2°C 
Resolution: 0.1°F / °C
Maximum Output: < 1 mW
Wavelength: 630 - 670 nm
Distance-Spot Ratio: 12:1
Response Time: < 500 ms
Emissivity (Adjustable): 0.1-1.0
Battery: DC 9V
1.  LCD Display
2.  Unit(°C/°F)/DOWN
3.  Emissivity Adjustment Mode
4.  UP/Laser Pointer/Backlight
5.  Measurement Trigger
6.  Battery Compartment
7.  Laser Hole
8.  IR Sensor
1.  Low Battery
2.  Laser On
3.  Back-light On
4.  Continue Scanning
5.  °C / °F
6.  Temperature Result
7.  Max Temperature / 
Emissivity Result
8.  Max Temperature Sign
9.  Adjustable Emissivity Sign
1.  Once the battery is properly installed, press the measurement trigger 
to activate the device.
2.  Point the Lasergrip towards the surface of measurement.
3.  Press and hold the measurement trigger and the laser will activate for 
aiming guidance.
4.  Keep holding the trigger as you move the Lasergrip if you wish to live 
scan the surface area for temperature measurement.
5.  Once the laser is pointed to the desired point of measurement, release 
the trigger and the LCD display will lock the calculated temperature.
6.  Press the measurement trigger once again to make another 
measurement.
• Keep the thermometer away from electromagnetic fields produced by 
objects such as arc welders and induction heaters.
•  DO NOT expose the thermometer to direct sources of heat for 
extended periods of time.
• The thermometer measures surface temperature, not internal 
temperature. Do not use the Lasergrip as a reliable source to measure 
body temperatures.
Surface Temperature Measurement
HOLD for continuous 
temperature reading
RELEASE to lock the 
temperature result
To switch between units of temperature 
measurement, press the °C/°F button at any 
time while the Lasergrip is on.
To activate and deactivate the laser, press the 
laser pointer On/Off button at any time while the 
Lasergrip is on.
To activate and deactivate the display backlight, 
press and hold measurement trigger and then 
press the display backlight On/Off button at the 
same time.
To adjust the emissivity value before 
measurement, press the emissivity adjustment 
mode button, then use the UP   and DOWM 
buttons to navigate to the desired value. You 
may refer to the emissivity reference chart for 
correct surface emissivity values. To transfer 
into Max Temperature Mode, press the mode 
button again. 
Unit Conversion
Laser Activation
Display Backlight Operation
Emissivity Adjustment & Max Temperature
Display Icon Key
Package Contents
1 x Etekcity Lasergrip 1080 Infrared Thermometer
1 x 9V DC Battery
1 x User Manual
Infrared Thermometer
Model No.: 
Lasergrip 1080
Questions or Concerns?
support@etekcity.com • (855)-686-3835
Produktspecifikationer
| Varumärke: | Etekcity | 
| Kategori: | Termometer | 
| Modell: | Lasergrip 1080 | 
Behöver du hjälp?
Om du behöver hjälp med Etekcity Lasergrip 1080 ställ en fråga nedan och andra användare kommer att svara dig
Termometer Etekcity Manualer
                        
                         29 December 2024
                        
                    
                                                            
                        
                         5 September 2024
                        
                    
                                                            
                        
                         5 September 2024
                        
                    
                                                            Termometer Manualer
- Proficare
 - PCE Instruments
 - Nedis
 - TQC
 - Turbotronic
 - Veroval
 - Tristar
 - Fora
 - Grado
 - ATN
 - EMOS
 - Joy-it
 - Blue Circle Medical
 - Welch Allyn
 - Geratherm
 
Nyaste Termometer Manualer
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         13 Oktober 2025
                        
                    
                                                            
                        
                         13 Oktober 2025
                        
                    
                                                            
                        
                         13 Oktober 2025
                        
                    
                                                            
                        
                         13 Oktober 2025
                        
                    
                                                            
                        
                         12 Oktober 2025
                        
                    
                                                            
                        
                         7 Oktober 2025
                        
                    
                                                            
                        
                         7 Oktober 2025
                        
                    
                                                            
                        
                         7 Oktober 2025