Läs gratis den bruksanvisning för Fluke 2AC (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 28 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 2 recensioner. Har du en fråga om Fluke 2AC eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

2AC
VoltAlert
Instruction Sheet
Read First: Safety Information
WX Warning
To avoid possible electric shock or personal injury:
●If the Tester is used in a manner not specied by the manufacturer,
protection provided by the Tester may be affected.
●Test on a known live source within the rated ac voltage range of the
product, both before and after use to ensure unit is in good working
condition.
●When using the Tester, if tip does not glow, voltage could still be
present. The Tester indicates active voltage in the presence of
electrostatic elds of sufcient strength generated from the source
(MAINS) voltage. If the eld strength is low, the Tester may not provide
indication of live voltages. Lack of an indication occurs if the Tester is
unable to sense the presence of voltage which may be inuenced by
several factors including, but not limited to:
●Shielded wire/cables
●Thickness and type of insulation
●Distance from the voltage source
●Fully-isolated users that prevent an effective ground
●Receptacles in recessed sockets/ differences in socket design
●Condition of the Tester and Batteries
●Do not use if the Tester appears damaged or if the Tester is not
operating properly. Specically examine the probe tip for cracks or
breakage before use. If in doubt, have the Tester serviced.
●Do not apply more than the rated voltage as marked on the Tester.
●Use caution with voltages above 30 V ac as a shock hazard may exist.
●Comply with local and national safety requirements.
●Use proper protective equipment as required by local or national
authorities.
Table 1. Symbols
T
Double Insulated.
X
Hazardous Voltage. Risk of electric shock.
W
Risk of danger. Important information. See Instruction Sheet.
Conforms to relevant Canadian and US Standards.
Conforms to relevant European Union directives.
Conforms to relevant Australian standards.
Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website
for recycling information.
CAT IVEquipment is designed to protect against transients from the primary supply level.
(i.e. - electricity meter or overhead /underground utility service).
August 2010 Rev. 1, 7/11
© 2010-2011 Fluke Corporation. Specications are subject to change without notice. All rights
reserved. Printed in China.
FOR USE BY COMPETENT
PERSONS
Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially
in an industrial setting, and the importance of
taking safety precautions and of testing the
instrument before and after using it to ensure
that it is in good working condition.
Produktspecifikationer
| Varumärke: | Fluke |
| Kategori: | Inte kategoriserad |
| Modell: | 2AC |
| Certifiering: | IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01 |
| Mätkategorier som stöds: | CAT IV |
| Produktens färg: | Black, White, Yellow |
| Temperatur vid drift: | -10 - 50 ° C |
| Temperaturintervall (förvaring): | -10 - 50 ° C |
| Uppmätt spänning: | 1000 V |
| Höjd över havet: | 2000 m |
Behöver du hjälp?
Om du behöver hjälp med Fluke 2AC ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Fluke Manualer
12 Mars 2025
9 Oktober 2024
7 Oktober 2024
5 Oktober 2024
1 Oktober 2024
29 September 2024
26 September 2024
24 September 2024
23 September 2024
22 September 2024
Inte kategoriserad Manualer
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025