Gossen Metrawatt METRACLIP 86 Bruksanvisning


Läs gratis den bruksanvisning för Gossen Metrawatt METRACLIP 86 (51 sidor) i kategorin Multimeter. Guiden har ansetts hjälpsam av 24 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 12.5 recensioner. Har du en fråga om Gossen Metrawatt METRACLIP 86 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/51
METRACLIP 86
CLAMP MULTIMETER
User’s manual
ENGLISH
Clamp Multimeter METRACLIP 86 English
CONTENTS
1
PRESENTATION............................................................................................................ 8
1.1 THE SWITCH ....................................................................................................................... 9
1.2 THE KEYS OF THE KEYPAD ........................................................................................ 10
1.3 THE DISPLAY UNIT ........................................................................................................ 11
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 13
1.4 THE TERMINALS ............................................................................................................. 13
2 THE KEYS ..................................................................................................................... 13
2.1
KEY ...................................................................................................................................... 13
2.2 KEY (SECOND FUNCTION) ................................................................................................... 14
2.3 KEY ...................................................................................................................................... 15
2.4 KEY ...................................................................................................................................... 15
2.4.1 In the normal mode ......................................................................................... 15
2.4.2 The MAX/MIN/PEAK mode + activation of the HOLD mode....................... 16
2.4.3 Access to the True-INRUSH mode ( set to )................................... 17
2.5 KEY ...................................................................................................................................... 17
2.5.1 The Hz function in the normal model ............................................................. 17
2.5.2 The Hz function + activation of the HOLD mode .......................................... 18
2.6 KEY ...................................................................................................................................... 18
3 USE .................................................................................................................................. 19
3.1 COMMISSIONING ........................................................................................................... 19
3.2 STARTING UP THE CLAMP MULTIMETER ............................................................. 20
3.3 SWITCHING THE CLAMP MULTIMETER ................................................................ 20
3.4 CONFIGURATION ........................................................................................................... 20
3.4.1 Programming of the maximum resistance allowed for a continuity.............. 21
3.4.2 De-activation of automatic switching off (Auto Power OFF) ....................... 21
3.4.3 Programming of the current threshold for the True INRUSH measurement 21
3.4.4 Default configuration ...................................................................................... 22
3.5 VOLTAGE MEASUREMENT (V).................................................................................. 22
3.6 CONTINUITY TEST ................................................................................................... 23
3.6.1 Automatic compensation of the resistance of the leads ................................. 24
3.7 RESISTANCE MEASUREMENT .............................................................................. 24
3.8 DIODE TEST ............................................................................................................... 25
3.9 CURRENT MEASUREMENT (A) .................................................................................. 25
3.9.1 AC measurement ............................................................................................. 25
3.9.2 DC or AC+DC measurement.......................................................................... 26
3.10 STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT
27
2
English Clamp Multimeter METRACLIP 86
3.11
POWER MEASUREMENTS W, VA, VAR AND PF ..................................................... 27
3.11.1 Measurement of single-phase power .............................................................. 28
3.11.2 Balanced three-phase power measurement.................................................... 28
3.12
DIRECTION OF ROTATION OF THE PHASES” OR “ORDER OF THE PHASES”
MODE .................................................................................................................................... 29
3.13 FREQUENCY MEASUREMENT (HZ) .......................................................................... 30
3.13.1 Frequency measurement in voltage ................................................................ 30
3.13.2 Frequency measurement in current ................................................................ 31
3.13.3 Measurement of frequency in power .............................................................. 31
3.14 MEASUREMENT OF THE LEVEL OF HARMONICS (THD) AND OF THE
FREQUENCY OF THE FUNDAMENTAL (NETWORK) ....................................................... 31
3.14.1 Measurement of the THD and of the frequency of the fundamental in voltage
32
3.14.2 Measurement of the THD and of the frequency of the fundamental in current
32
4 CHARACTERISTICS .................................................................................................. 34
4.1 REFERENCE CONDITIONS ........................................................................................... 34
4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS ......................... 34
4.2.1 DC voltage measurement ................................................................................ 34
4.2.2 AC voltage measurement ................................................................................ 35
4.2.3 AC+DC voltage measurement ........................................................................ 36
4.2.4 DC current measurement ................................................................................ 36
4.2.5 AC current measurement ................................................................................ 37
4.2.6 AC+DC intensity measurement ...................................................................... 37
4.2.7 True-Inrush measurement ............................................................................... 38
4.2.8 Continuity measurement ................................................................................. 38
4.2.9 Resistance measurement ................................................................................. 38
4.2.10 Diode test ......................................................................................................... 39
4.2.11 Active DC power measurements ..................................................................... 39
4.2.12 Active AC power measurements ..................................................................... 40
4.2.13 Active AC+DC power measurements ............................................................. 41
4.2.14 Measurement of apparent AC power .............................................................. 42
4.2.15 Measurement of apparent AC+DC power ..................................................... 42
4.2.16 Measurement of reactive AC power ............................................................... 43
4.2.17 Measurement of reactive AC+DC power ....................................................... 43
4.2.18 Calculation of the power factor ...................................................................... 44
4.2.19 Frequency measurements................................................................................ 45
4.2.20 Characteristics in THDr ................................................................................. 45
4.2.21 Characteristics in THDf .................................................................................. 45
4.2.22 Indication of order of the phases .................................................................... 46
4.3 ENVIRONMENTAL CONDITIONS .............................................................................. 46
4.4 CHARACTERISTICS OF CONSTRUCTION............................................................... 47
4.5 POWER SUPPLY............................................................................................................... 47
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS........................................ 47
3


Produktspecifikationer

Varumärke: Gossen Metrawatt
Kategori: Multimeter
Modell: METRACLIP 86

Behöver du hjälp?

Om du behöver hjälp med Gossen Metrawatt METRACLIP 86 ställ en fråga nedan och andra användare kommer att svara dig