Haws 8315CTFP Bruksanvisning

Haws Duschsystem 8315CTFP

Läs gratis den bruksanvisning för Haws 8315CTFP (13 sidor) i kategorin Duschsystem. Guiden har ansetts hjälpsam av 22 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 11.5 recensioner. Har du en fråga om Haws 8315CTFP eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/13
10/20 Model 8315CTFP (120V) & 8315CTFP.220V Page 1 of 13
1455 Kleppe Lane Sparks, NV 89431-
6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
No. 0510001018 (2)
Model 8315CTFP (120V) &
8315CTFP.220V
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipment. HAWS liability under this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods,
or part thereof, which shall appear to the Company upon inspection to be of defective
material or not of first class workmanship, provided that claim is made in writing to Haws
within a reasonable period after receipt of the product. Where claims for defects are made,
the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS
will not be liable for the cost of repairs, alterations or replacements, or for any expense
connected therewith made by the owner or his agents, except upon written authority from
HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective
materials or poor workmanship, except for replacements, as provided above. Buyer agrees
that Haws has made no other warranties either expressed or implied in addition to those
above stated, except that of title with respect to any of the products or equipment sold
hereunder and that HAWS shall not be liable for general, special, or consequential damages
claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. The units also must be used for the
purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED
OR GIVEN BY HAWS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297
10/20 Model 8315CTFP (120V) & 8315CTFP.220V Page 2 of 13
RECOMMENDED TOOLS & SUPPLIES:
Pipe wrenches (both with teeth and smooth jaws)
Power drill with #2 Phillips bit (preferred), or #2 Phillips screwdriver (preferably ratcheting)
Adjustable wrench (or a standard wrench set up 7/8)
7/32" hex key
Level
Three (3) rust-resistant anchors (3/8” diameter)
Pipe joint sealant (Loctite PST #567 recommended)
Silicone caulking (Dow Corning 832 recommended)
Stepladder
LOCATION OF UNIT:
The Model 8315CTFP (120V) & 8315CTFP.220V Emergency Shower Eye/Face Wash should be installed in
close proximity to potential accident areas. It should be clearly identified, free from obstructions, and easy to
access.
Suitable for use in Class 1, Division 2 Group B,C,& D areas.
Temperature rating T6 (85°C).
ELECTRICAL SUPPLY: During potentially freezing periods, ensure that unit is connected to a continuous
power supply.
MODEL 8315CTFP: Electrical power required for standard heat traced unit is 120 VAC. Average power
consumption at 50°F (10°C) ambient temperature is 110 watts. Maximum without lighting is 130 watts.
Connection at input junction box is 3/4” NPT.
MODEL 8315CTFP.220V: Electrical power required for standard heat traced unit is 220 VAC. Average
power consumption at 50°F (10°C) ambient temperature is 110 watts. Maximum without lighting is 130 watts.
Connection at input junction box is 3/4" NPT.
WATER SUPPLY: Water supply must be freeze protected.
The minimum recommended line is 1-1/4” IPS with 30-90 psi (2-6 ATM) flowing pressure.
An inlet filter is recommended where sediment or mineral content is a problem.
Main inlet connection is 1-1/4” IPS.
Optional SP121 auxiliary outlet plumbing is 1-1/4 IPS.
MAINTENANCE:
Allow eye/face wash piping to drain out completely before replacing eye/face wash dust cover.
In freezing conditions, wipe eye/face wash head and dust cover dry after each use to prevent unwanted ice
buildup.
During regular testing, also verify these items:
o Verify that both the eye/face wash and the shower are able to drain completely.
o Verify that the dust cover is intact and firmly in place.
Optional SP158.15 Freeze Protection Valve is a field serviceable item; refer to its manual for more
information.
WARNING: Fire and shock hazards must use a ground fault electrical protection device (30mA GFEPD) for
heat trace. Electrical fault currents may be insufficient to trip a conventional circuit breaker.
10/20 Model 8315CTFP (120V) & 8315CTFP.220V Page 3 of 13
INSTALLATION PROCEDURE
STEP 1: Unboxing
The following components are included with this model. Note the locations within the packaging and the
pertinent installation steps included for reference.
Top Tray
6 plastic jacket components………….Step 6
Large Internal Carton
Painted metal floor flange……………Steps 2-3
Plastic shower bell…………………Step 4
6 lengths of seal trim………………Step 6
Note colored tape
Universal shower sign………………..Step 9
Small Internal Carton
Piping connector………………………Step 3
Piping union……………………………Step 3
6 large zip ties………………..............Steps 3 & 5
2 piping elbows………………………..Step 4
Bag
Eye/face wash assembly…….Step 7
Bag
Metal shower lever…………...Step 7
Eyewash push flag…………...Step 7
Paper test tag………………...Step 9
Bag
Plastic shower nozzle………..Step 4
Plastic hole plug………………Step 7
Plastic shower handle………..Step 7
Bag
Retaining ring…………………Step 4
Nut, shower lever…………….Step 7
Shower handle bolt…………..Step 7
Push flag nut………………….Step 7
2 adhesive rubber covers……Step 7
4 thread-forming screws……..Step 9
Small zip tie……………………Step 9
Central Area of Main Carton
Factory-assembled section………….Steps 3-9
2 insulation tubing sections………….Step 5
Bottom Area of Main Carton
1-1/4 pipe nipple……………………..Step 3
2 1 pipe nipples……………………..Step 4
2 expanded foam support…………...Step 6
spacers for the horizontal
shower piping
Expanded foam support……………..Step 6
spacer for the vertical
shower piping
Refer to the Installation Drawing for further details.


Produktspecifikationer

Varumärke: Haws
Kategori: Duschsystem
Modell: 8315CTFP

Behöver du hjälp?

Om du behöver hjälp med Haws 8315CTFP ställ en fråga nedan och andra användare kommer att svara dig