Hoshizaki HS-5453 Bruksanvisning

Läs gratis den bruksanvisning för Hoshizaki HS-5453 (5 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 2 recensioner. Har du en fråga om Hoshizaki HS-5453 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/5
1
2A9096-010
Hoshizaki Heated Condensate Pan Kit
HS-5453
For Use with the Following Commercial and Steelheart Series:
A. CPT and PR Models: 46, 67, and 93
B. Freezer and Prep Table Models: 48, 60, and 72
Check to ensure that all parts are included:
Index
Part
Number Qty
Index
No. Description
Part
Number Qty
1 Heated Condensate Pan 3B0185-01 1 5 Condensate Drain Hose 4A0658L01 1
2 Condensate Pan Bracket 2A9087-01 1 6 8911-0200 4Nylon Ties
3 Wire Harness Receptacle 4A6049-01 1 7 Bell Connector 8101-14CE 3
4 Self-Drilling Hex Screw 7B03I1210 4 8 Wiring Label 3B0188-01 1
WARNING
• Only qualied service technicians should install and service the appliance to reduce the risk of death, electric
shock, serious injury, or re.
• No installation or service should be undertaken until the technician has thoroughly read these instructions.
Failure to follow these instructions will adversely affect safety, performance, component life and warranty
coverage, and may result in costly water damage.
• See the instruction manual included with the appliance for installation instructions and safety information not
covered in this instruction sheet. If an instruction manual is not available, visit www.hoshizaki.com or contact
your Hoshizaki distributor.
Appliance is heavy. Use care when lifting or positioning. Work in pairs when needed to prevent injury or
damage.
To reduce the risk of electric shock, do not touch the plug with damp hands. Unplug the appliance from the
electrical outlet before servicing.
• Protect the oor when moving the appliance to prevent damage to the oor.
Wear proper personal protection equipment (PPE) when executing these procedures.
A. Installation Instructions for CPT and PR Models
1) On existing models, unplug the appliance from the electrical outlet, then remove all product from the appliance.
2) Move the appliance out to access the rear of the appliance, then lock the casters.
3) On new appliance installation, from the instruction manual, follow and complete all of the installation instructions up to section
"II.E. Door/Drawer Reversal".
4) Remove the front, left side, and rear louver panels. See Fig. 1. Next, remove the current condensate pan and condensate pan
brackets as shown in Fig. 2 and discard, then remove the condensate drain hose. Note: Remove elbow from condensate drain hose
for re-use, then discard condensate hose.
Fig. 1
Rear Louver
Panel
Left Side
Panel
Front Panel
Current
Condensate Pan
Current Condensate
Pan Bracket
Model Shown: PR46A
Fig. 2
Condensate
Drain Hose
Elbow
2
2A9096-010
5) Secure the new condensate pan bracket provided in this kit, with the self-drilling hex screws provided in this kit to the inner wall of
the lower panel. See Fig. 3.
6) Place the new heated condensate pan on the base of the new condensate pan bracket. See Fig. 4.
7) Place the new condensate drain hose over the condensate drain. See Fig. 5. Note: When placing the new condensate drain hose
into position, be sure that the elbow nor the new condensate drain hose make contact with the heater. (Adjust as necessary).
B. Installation Instructions for Freezer and Prep Table Models
1) On existing models, unplug the appliance from the electrical outlet, then remove all product from the appliance.
2) Move the appliance out to access the rear of the appliance, then lock the casters.
3) On new appliance installation, from the instruction manual, follow and complete all of the installation instructions up to section
"II.F. Glass Door Reversal".
4) Remove the rear louver panel. See Fig. 6.
New Condensate
Pan Bracket
Self-Drilling
Hex Screws
Model Shown: PR46A
Fig. 3
New Condensate
Pan Bracket
Inner Wall
Lower Panel
New Heated
Condensate Pan
Fig. 4
Heater
Model Shown: PR46A
Fig. 5
Heater
New Condensate
Drain Hose
Condensate Drain
New Condensate
Drain Hose
Fig. 6
Rear Louver
Panel
Model Shown: UF48A
Note: Make sure
condensate hose
or elbow does not
make contact
with heater.
3
2A9096-010
5) Next, remove the current condensate pan (if applicable) and condensate pan brackets (if applicable), and discard. See Fig. 7.
Specic Instructions for Models: UF48A and WF48A
6) Remove the truss head screw securing the blocking panel to the bottom panel. See Fig. 8. Next, place and level the condensate
pan bracket on the blocking panel, then using the self-drilling hex screws provided in this kit, secure the condensate pan bracket
provided in this kit to the bottom panel as shown in Fig. 9. Note: Verify that the condensate pan bracket is level.
(Adjust as necessary).
Condensate
Pan Bracket
Model Shown: UF48A
Fig. 7
Condensate
Pan
Model Shown: UF60A
Condensate
Pan
Condensate
Drain Hose
Condensate
Drain Hose
Model Shown: UF60A
Fig. 10
Truss Head
Screw
New Condensate
Pan Bracket
Self-Drilling
Hex Screws
Bottom
Panel
Model Shown: UF48A
Bottom
Panel
New Condensate
Pan Bracket
Specic Instructions for Freezer and Prep Table Models (Except UF48A and WF48A Models)
6) Using the self-drilling hex screws, secure the condensate pan bracket to the mounting holes on the bottom panel. See Fig. 10.
Fig. 8 Fig. 9
Blocking
Panel
Bottom
Panel
Self-Drilling
Hex Screws
Blocking
Panel
Mounting
Holes