Kidde 30CUDR-VCA Bruksanvisning

Kidde rökdetektor 30CUDR-VCA

Läs gratis den bruksanvisning för Kidde 30CUDR-VCA (2 sidor) i kategorin rökdetektor. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 3.6 stjärnor baserat på 2 recensioner. Har du en fråga om Kidde 30CUDR-VCA eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
VOICE ALERTS
Crystal-clear voice alerts in English and French tell you exactly
why your alarm is sounding so you can react quickly.
REDUCED NUISANCE ALARMS
Enhanced sensing technology reduces false alarms often
caused by cooking.
SELFTESTING**
For added assurance, internal components ensure alarm
is always operating as expected.
Description
North America’s #1 home fire safety brand* is bringing you the next level of
fire and carbon monoxide safety with the Kidde Combination Smoke and
Carbon Monoxide Alarm model 30CUDR-VCA.
This alarm oers a modern design ideal for all living spaces. Cutting edge
technology sends fast alerts that give your family more time to get out safely
and enhanced sensing technology reduces false alarms often caused by
cooking.
Comprehensively tested and designed to UL/ULC/CSA standards
for safety and reliability, this Kidde DETECT alarm is powered by 2 AA
replaceable batteries (included) for continual detection even during outages
and alerts you to both smoke & carbon monoxide (CO) using a single, cost-
eective device.
Plus, it’s self-testing and easy to install with the included twist-and-click
mounting bracket. Equipped with end-of-life notifications, the alarm will beep
to remind you it’s time to replace it 10 years after it is powered. This model
features voice alerts to tell you exactly why your alarm is sounding so you
can react quickly.
Alarm WarningsFeaturing multi-color LEDs
Fire: The red LED will flash in sync with the alarm pattern (3 long beeps).
The alarm will repeat this pattern until the unit is reset or smoke is eliminated.
Carbon Monoxide: The red LED will flash in sync with the alarm pattern
(4 quick beeps). This continues until the unit is reset or the CO is eliminated.
Low Battery: One chirp and amber LED flash per minute.
Alarm Memory: Alerts a user if smoke or CO has been detected in the last
24 hours. If smoke has been detected, the red LED blinks every 15 sec. If CO
has been detected, the red LED blinks twice every 15 sec.
Features & Benefits
Double the Detection – Alerts you to both smoke & carbon monoxide
(CO) using a single, cost-eective device.
2 AA Replaceable Batteries – Provides power even during short-term
power outages for extra peace of mind. Change replaceable batteries
every 6 months, or when you hear the low battery chirp.
Voice Alerts – Crystal-clear voice alerts in English and French tell you
exactly why your alarm is sounding so you can react quickly.
Self-Testing Alarms** – For added assurance, internal components
ensure alarm is always operating as expected.
Simple Installation – Easy install with included twist-and-click
mounting bracket.
End-of-Life Notifications – This alarm beeps to remind you it’s time to
replace it 10 years after it is powered.
*Based on total household installations as of December 2023. **Self-testing is not a substitute
for a manual push test of the alarm. Perform a button test once per week to verify proper alarm
operation.
SMOKE +
CO ALARM
DETECT SERIES | MODEL 30CUDR-VCA | ITEM 21032771
2 AA BATTERIES INCLUDED
Images are representative only.
Actual product may vary slightly.
Installation of Alarm
This model meets the latest residential smoke alarm standards, which
includes enhanced resistance to nuisance alarms from cooking. Industry
experts recommend that both ionization and photoelectric smoke alarms be
installed to help ensure optimal detection of the various types of fires that
can occur within the home. Ionization sensing alarms may detect invisible fire
particles (associated with fast flaming fires) sooner than photoelectric alarms.
Photoelectric sensing alarms may detect visible fire particles (associated
with slow smoldering fires) sooner than ionization alarms. Industry experts
recommend specific locations for smoke alarms, such as every level and
sleeping area of the dwelling. They also recommend a CO alarm be installed
on each level of the home — ideally on any level with fuel-burning appliances
and outside of sleeping areas. The alarm can be installed on the surface of
any wall or ceiling following the UL/ULC/NFPA/Manufacturer’s recommended
placement guidelines. See User Guide for more location information and
additional instructions.
Architectural & Engineering Specifications
WARNING: This product is intended for use in ordinary indoor locations of family
living units. It is not designed to measure compliance with commercial or industrial
standards. It is not suitable for installation in hazardous locations as defined in the local
building code.
This device is designed to protect individuals from acute eects of carbon
monoxide exposure. It will not fully safeguard individuals with specific medical
conditions. If in doubt, consult a medical practitioner. Individuals with medical
problems may consider using warning devices which provide audible and
visual signals for carbon monoxide concentrations under 30 ppm.
CO alarm response times:
70 ppm: 60-240 min
150 ppm: 10-50 min
400 ppm: 4-15 min
The alarm shall include a test button that will electronically simulate the
presence of smoke and CO and cause the unit to go into both modes of
alarm. This sequence tests the unit’s electronics to ensure proper operation.
The unit shall incorporate three LED colors. A green LED will flash every
60 seconds when in standby condition. An amber LED will indicate fault
conditions. A red LED will flash in sync with the smoke alarm pattern, and will
also indicate alarm memory.
The unit shall include the HUSH™ feature that silences a smoke alarm
for approximately 8-10 minutes if a nuisance alarm condition occurs. The
red LED on the alarm will flash every 2 seconds while in HUSH and will
automatically reset itself.
At the date of manufacture, the unit shall at a minimum meet the
requirements of ULC 531, UL 217, CSA 6.19-17, UL 2034, NFPA 72, NFPA 101
(one- and two-family dwellings).
Technical Specifications
Model: 30CUDR-VCA
Power Source: 2 AA battery operated
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Audio Alarm: 85 dB at 3m (10 ft)
Temperature Range: 4.4˚C (40˚F) to 37.8˚C (100˚F)
Humidity Range: 10 to 95% relative humidity (RH), non-condensing
Size: 12.7 cm x 5.1 cm x 12.7 cm
Weight: 0.39 kg
Wiring: N/A
Interconnects: N/A
Warranty: 10-Year Limited Warranty (batteries excluded)
Replacement Batteries: Energizer E91, Gold Peak 15A or Golden Power
GLR6A. Replacement batteries are available
where you purchased this alarm.
Note: Do not use Lithium batteries in this unit.
Ordering Information
Ordering Number UPC I 2 of 5 Pack Config
Master
Carton Qty
Case Dimensions
(w x d x h cm)
Master Carton
Weight (kg)
Master
Cartons/Pallet
380-21032771 047871327713 10047871327710 1 alarm in retail box 6 retail boxes 16 x 38.1 x 15.4 2.63 108
SMOKE + CARBON MONOXIDE ALARM | DETECT SERIES | MODEL 30CUDR-VCA
Kidde Canada Inc., C.P. / P.O. Box 40, Apsley, (ON) K0L 1A0 1-800-880-6788 kiddecanada.com
©2025 Kidde. All Rights Reserved. All trademarks and service marks referred herein are property of their respective owners.


Produktspecifikationer

Varumärke: Kidde
Kategori: rökdetektor
Modell: 30CUDR-VCA

Behöver du hjälp?

Om du behöver hjälp med Kidde 30CUDR-VCA ställ en fråga nedan och andra användare kommer att svara dig