Klein Tools VDV500-920 Bruksanvisning

Läs gratis den bruksanvisning för Klein Tools VDV500-920 (32 sidor) i kategorin Mätutrustning. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 9 recensioner. Har du en fråga om Klein Tools VDV500-920 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/32
INSTRUCTION MANUAL
ENGLISH
VDV500-920
Digital Toner-Pro and
Digital Probe-Pro Kit
Digital Toner-Pro and
Digital Probe-Pro Kit
Digital Toner-Pro and
FRANÇAIS
p. 21
ESPAÑOL
pág. 11
Digital Toner-Pro and
Digital Probe-Pro Kit
Digital Toner-Pro and
Digital Probe-Pro Kit
Digital Toner-Pro and
TRACE INDIVIDUAL
OR PAIRED WIRES
TRACE SHORTED
OR CONNECTED WIRES
VIA DIGITAL TONING
TEST RJ11, RJ12, AND RJ45 JACKS
TEST RJ11, RJ12, AND RJ45 JACKS
DETECTS CONTINUITY AND POLARITY
DETECTS CONTINUITY AND POLARITY
3 DISTINCT TONES
(2 CONSTANT, 1 ALTERNATING)
(2 CONSTANT, 1 ALTERNATING)
EASY-TO-UNDERSTAND
STATUS LED
s
SEND TONES ON
SHORTED OR
CONNECTED WIRES
CONNECTED WIRES
VIA DIGITAL TONING
VIA DIGITAL TONING
PERFORM
PIN-TO-PIN
MAPPING
REPLACEABLE
PROBE TIP
VDV500-223
VDV500-163
2
ENGLISH
GENERAL SPECIFICATIONS - VDV500-163 DIGITAL TONER-PRO
The Klein Tools VDV500-163 Digital Toner-Pro is a professional-series
analog and digital tone generator for wire identification, wire tracing and
wire pair identification. It features several tone frequencies and strong
power output for tracing wires.
Operating Altitude:
6562 ft. (2000 m) maximum
Relative Humidity:
10% – 90% non-condensing
Operating Temp:
32° to 122° F (0° to 50°C)
Storage Temp:
-4° to 140°F (-20° to 60°C)
Dimensions:
4.65" × 2.52" × 1.10" (118 × 64 × 28 mm)
Weight:
5.29 oz. (150 g) including batteries
Battery Type:
4 × 1.5V AAA Alkaline
Battery Life: Active:
20 hours
Standby/Storage:
3 years
Auto-Power Off:
After 60 minutes of inactivity
Analog Tones:
Constant:
1000Hz, 1500Hz
Alternating:
1000Hz/1500Hz
Tone Power:
8dBm
Continuity Indication:
Less than 10kΩ
Voltage Protection: Test Mode:
60V
Tone Mode:
20V through external 600Ω
Specifications subject to change.
T17T17
T12T12
T16T16
FEATURE DETAILS - VDV500-163 DIGITAL TONER-PRO
SYMBOLS - VDV500-163 DIGITAL TONER-PRO
Warning or Caution
Conformité Européenne:
Conforms with European
Economic Area directives
Always wear approved
eye protection
UKCA:
UK Conformity Assessment
Do NOT use on
energized circuits
WEEE:
Electronics disposal
Read instructions
3
T1
T1
TEST MODE Indicator
T2
T2
"NRM" (Normal)
Polarity Indicator
T3
T3
"REV" (Reverse)
Polarity Indicator
T4
T4
"CONT" (Continuity)
Indicator
T5
T5
TONE MODE
Indicator
T6
T6
Analog Tone
Frequency Indicators
T7
T7
Digital/Analog Tone
Button
T8
T8
Mode button
T9
T9
Power On/Off Button
T10
T10
Pin/Pair Selection
Button
T11
T11
Battery Status
Indicator
T12
T12
Lanyard Slot
T13
T13
Digital Tone Indicator
T14
T14
Red ABN (Angled
Bed-of-Nails) Test Clip
T15
T15
Black ABN (Angled
Bed-of-Nails) Test Clip
T16
T16
Battery Cover
T17
T17
Battery Cover Screw
T18
T18
Wire Map Indicator
T19
T19
Shield Indicator
T20
Test Lead Inputs
T21
RJ45 Port
T1
T1
T10
T10
T10
T11
T11
T11
T19
T19
T19
T8
T8
T2
T2
T3
T3
T5
T5
T7
T7
T13
T13
T13
T9
T9
T4
T4
FEATURE DETAILS - VDV500-163 DIGITAL TONER-PRO
T15T15
T14T14
T6
T6
T18
T18
T18
WARNINGS
To ensure safe operations and service of the instruments, follow these instructions.
Failure to observe these warnings can result in  re, electric shock, severe injury or death.
To ensure safe operations and service of the instruments, follow these instructions.
Failure to observe these warnings can result in  re, electric shock, severe injury or death.
To ensure safe operations and service of the instruments, follow these instructions.
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
voltage cabling systems (less than 60V) for testing when
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
voltage cabling systems (less than 60V) for testing when
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
NOT
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
NOT
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
energized.
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
energized.
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
NOT energized.NOT
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
NOT
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
energized.
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
NOT
The Digital Toner-Pro, test leads, and Digital Probe-Pro, are designed for use on extra-low
The maximum voltage across ABN Test Clips of the Digital Toner-Pro is 60V in Test
mode, and 20V in Continuity mode. Connecting the Digital Probe-Pro to live mains AC
The maximum voltage across ABN Test Clips of the Digital Toner-Pro is 60V in Test
mode, and 20V in Continuity mode. Connecting the Digital Probe-Pro to live mains AC
The maximum voltage across ABN Test Clips of the Digital Toner-Pro is 60V in Test
power may damage it and pose a safety hazard for the user.
mode, and 20V in Continuity mode. Connecting the Digital Probe-Pro to live mains AC
power may damage it and pose a safety hazard for the user.
mode, and 20V in Continuity mode. Connecting the Digital Probe-Pro to live mains AC
DO NOT
use instruments if they are wet, as it could pose a shock hazard.
DO NOT use instruments if they are wet, as it could pose a shock hazard.DO NOT
DO NOT
use instruments if they are damaged in any way.
DO NOT use instruments if they are damaged in any way.DO NOT
Turn off instruments and disconnect all ABN Test Clips before attempting to replace batteries.
The battery door must be in place and secure before you operate the instrument.
DO NOT
open the case, other than the battery compartment.
DO NOT open the case, other than the battery compartment.DO NOT
T21
T21
T21
T20
T20
T20

Produktspecifikationer

Varumärke: Klein Tools
Kategori: Mätutrustning
Modell: VDV500-920

Behöver du hjälp?

Om du behöver hjälp med Klein Tools VDV500-920 ställ en fråga nedan och andra användare kommer att svara dig