Klein Tools VDV526-054 Bruksanvisning
Klein Tools
Mätutrustning
VDV526-054
Läs gratis den bruksanvisning för Klein Tools VDV526-054 (25 sidor) i kategorin Mätutrustning. Guiden har ansetts hjälpsam av 13 personer och har ett genomsnittsbetyg på 3.6 stjärnor baserat på 7 recensioner. Har du en fråga om Klein Tools VDV526-054 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/25

Instruction
Manual
TraceAll™
Tone & Probe
VDV526-054
ENGLISH
• AdjuStAbLE
VoLumE
• NoN-CoNduCtIVE,
Replaceabletip
• integRatedgeneRatoR
StorAGE
• twotonestyles
• autopoweRoff
• RJ11/12Jack
Español pg. 7
Português pg. 13
Français pg. 19

2
ENGLISH
TraceAll™ Tone & Probe
The Klein Tools TraceAll™ Tone & Probe is a portable device that assists in
tracing. It includes a tone generator that places a low voltage signal on the
line, and a tracer that detects and amplifies the signal.
• Dimensions: 8.9” x 1.7” x 1.2” (22.6 x 4.3 x 3.0 cm)
• Weight: 5.0 oz. (140 grams) with battery and remote
• 0 °C to 50 °C / 32°F to 122°F
• -20 °C to 60 °C / -4°F to 140 °F
• Humidity: 10% to 90%, non-condensing
• without damage:
• 250V
• 175V RMS
• :
• 10 hours, 6V – 4 x LR44 alkaline batteries
• 50 hours, 6V – 4 x LR44 alkaline batteries
• 12 volts peak-to-peak no load, new battery
• 8.9 dbm into 600 ohms, new battery
•
1116Hz and 919Hz ±5%
• Cat No. VDV999-059
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Connecting the TraceAll™ to live AC power may damage it and pose a
safety hazard for the user.
• Poorly terminated RJ plugs have the potential to damage the jack on
the TraceAll™. Visually inspect a RJ plug before inserting it into the
generator. The contacts should always be recessed into the plastic
housing of the plug.

3
AttrIbutES
1. Remove generator from tracer by squeezing finger grips at rear of
the tracer and pulling out the generator.
2. Connect the TraceAll™ generator to the cable being traced using the
RJ11/12 jack on the generator. Connect an RJ11/12 terminated cable
directly or connect any other cable type using the included alligator
clips adapter.
3. Press the button on top of the generator. The button will flash to
indicate the tone generator is powered on. A long press will toggle
the tone cadence. Another short press will turn off the generator.
The flash rate is different between the two cadences.
4. Turn on the probe by pressing and holding the black button.
5. Adjust the volume on the probe to a comfortable level by turning
the dial on the side (clockwise raises the volume). If the signal
is very loud when near the cable, reduce the volume to avoid
overloading the TraceAll™. When the probe is overloaded, small
increases or decreases of the signal at the tip cannot be heard.
6. Hold the tip of the probe near the cable to be identified.
The signal will be loudest on the wire or cable attached to the
generator. Separating the wires or cables may help in isolating
the correct cable.
Produktspecifikationer
Varumärke: | Klein Tools |
Kategori: | Mätutrustning |
Modell: | VDV526-054 |
Behöver du hjälp?
Om du behöver hjälp med Klein Tools VDV526-054 ställ en fråga nedan och andra användare kommer att svara dig
Mätutrustning Klein Tools Manualer
14 Januari 2025
14 Januari 2025
2 Januari 2025
29 December 2024
26 September 2024
26 September 2024
26 September 2024
23 September 2024
23 September 2024
23 September 2024
Mätutrustning Manualer
- Kogan
- Softing
- GW Instek
- Peak
- Voltcraft
- GQ
- Topex
- X-Rite
- Omnitronic
- Bosch
- Pioneer
- Greisinger
- INFICON
- Joy-it
- Microlife
Nyaste Mätutrustning Manualer
3 April 2025
3 April 2025
3 April 2025
3 April 2025
3 April 2025
3 April 2025
3 April 2025
3 April 2025
3 April 2025
3 April 2025