Läs gratis den bruksanvisning för Kohler Freewill K-12208 (24 sidor) i kategorin dusch huvud. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 7 recensioner. Har du en fråga om Kohler Freewill K-12208 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/24
1011310-2-B
2002 Kohler Co.
Español, Página 17
Français, Page 9
FREEWILL BARRIER-FREE
MULTI-PIECE SHOWER MODULES
K-12200, K-12201, K-12207,
K-12208
BEFORE YOU BEGIN
PREPARATION
Install the unit to a level subfloor.
Provide properly dimensioned framing.
Insulate all exterior walls before installation.
The basin area requires no additional support
when the subfloor is plumb and level with respect
to the stud frame. Shim as needed to level the
module.
For optimum accessibility, specify faucets and
fittings to install and operate within the control area
shown in the roughing-in diagrams.
ACCESS REQUIREMENTS
Be sure you have enough access to move the
module into the construction area.
One-piece shower modules are too large to fit
through standard door openings. Therefore, this
multi-piece module is designed to be separated
into sections for moving into the installation area.
Once near the installation area, reassemble the
module and move it within the installation area.
TRANSPORTATION/PROTECTION
Protect the floor of the module during installation.
When moving the module, avoid flexing the side
walls to prevent radius cracking.
Until you are ready to begin the actual installation,
leave the packaging material in place to prevent
damage. Protect the module from damage.
Protect the module from damage after installation.
CODE CONSIDERATIONS
When fire-rated wall is specified, the stud opening
dimensions are to the inside of the wallboard.
If the module is to be installed adjacent to vertical
ducts or chases, fire-rated wallboard should
surround the module.
OTHER PLUMBING CONCERNS
Before beginning, consult all applicable
instructions included with options and accessories.
In locations where plumbing is adjacent to a
masonry wall, make provisions for access to the
connections. Construct a separate wall at least 6”
(15.2cm) from the masonry wall. Install furring
when the back of the unit is against the masonry
wall.
Connect the valve to the water supplies, and check
for leaks before installing the module.
Locate the rough plumbing for the drain in
accordance with the roughing-in dimensions.
Position the plumbing as required by the
manufacturer’s instructions.
Before installation, provide access to all
connections. Because the module must be
installed as an assembled “one-piece” module, the
drain and overflow connections cannot be made by
reaching over the end of the module.