Läs gratis den bruksanvisning för Liftmaster CPS-OPEN4 (8 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 20 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 10.5 recensioner. Har du en fråga om Liftmaster CPS-OPEN4 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/8

1
LIFTMASTER® PROTECTOR SYSTEM
MODEL CPS-OPEN4
APPLICATION
LiftMaster® Protector System model CPS-OPEN4 is a monitored entrapment protection device for use with sectional and rolling doors. This device is
compatible with LiftMaster Heavy, Standard, and Medium Duty Logic (post 2010), FDC, FCL, FDOA, FDOB, and Egress Commercial Door operators. This
device may be installed in areas exposed to rain or moisture. These images in this document are for reference only and your product may look different.
SPECIFICATIONS
Power Consumption: Max. 50mA
Supply Voltage: 6 to 40 Vdc
Operating Temperature: -13°F to 165°F (-25°C to 73°C)
NEMA4 rating
CARTON INVENTORY
Photoelectric sensors (transmitter and receiver), mounting brackets (2), hardware, and instructions
LIFTMASTER® PROTECTOR SYSTEM
IMPORTANT INFORMATION ABOUT THE PHOTOELECTRIC SENSOR
Be sure power to the operator is disconnected.
When properly connected and aligned, the photoelectric sensor will detect an obstruction in the path of its beam. If an obstruction breaks the beam while
the door is closing, the operator will stop and typically reverse to the full open position.
The transmitter must be installed so that it faces the receiver across the entrapment zone, no more than 6" (15 cm) above the fl oor for a door. Minimum
installation width of 3 feet (.91 m) and maximum width of 45 feet (13.7 m).
The brackets must be securely fastened to a solid surface such as the wall framing. If installing in masonry construction, add a piece of wood at each
location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the
beam while the door is closing.
ENTRAPMENT ZONES
Make sure the brackets are aligned so the photoelectric sensors will face each other across the entrapment zone as illustrated.
ENTRAPMENT ZONE FOR COMMERCIAL DOOR APPLICATION
To prevent possible SERIOUS INJURY or DEATH from a closing door:
• Be sure to DISCONNECT POWER to the operator BEFORE installing the photoelectric sensor.
• The door MUST be in the fully opened or closed position BEFORE installing the LiftMaster
® Monitored Entrapment Protection device.
• Correctly connect and align the photoelectric sensor.
• Install the photoelectric sensor beam NO HIGHER than 6" (15 cm) above the fl oor.
• LiftMaster® Monitored Entrapment Protection devices are for use with LiftMaster
® Commercial Door. Use with ANY other product voids the
warranty.
• Entrapment protection devices MUST be installed per the operator owner's manual for each Entrapment Zone.
Photoelectric
Sensor
Entrapment Zone Invisible Light Beam
Protection Area
Photoelectric
Sensor
6" (15 cm) max. above the
floor and away from the door
6" (15 cm) max. above the
floor and away from the door
Facing the door from inside the building
(Installation procedures are the same for all door types)
Produktspecifikationer
| Varumärke: | Liftmaster |
| Kategori: | Inte kategoriserad |
| Modell: | CPS-OPEN4 |
Behöver du hjälp?
Om du behöver hjälp med Liftmaster CPS-OPEN4 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Liftmaster Manualer
25 September 2024
24 September 2024
24 September 2024
23 September 2024
23 September 2024
23 September 2024
23 September 2024
23 September 2024
23 September 2024
17 September 2024
Inte kategoriserad Manualer
- McCulloch
- Ilford
- Beltronics
- Velux
- Gaggia
- Atlas
- Huion
- Foscam
- Jabra
- Zoofari
- Icarus Blue
- NEXTO DI
- Ariete
- Peavey
- Davita
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025