Läs gratis den bruksanvisning för Liftmaster TLS1CARD (12 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 9 recensioner. Har du en fråga om Liftmaster TLS1CARD eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/12

1
TLS1CARD
TIMER LIGHT STATUS OPTION CARD
The TLS1CARD has different configuration modes that determine how the TLS1CARD will function.
MODE COMPARABLE MODIFICATION DESCRIPTION
90-T1, 90-515774, or RDGRNCARD • 3 relay outputs (R1, R2, and R3) with optional flashing for R1TCP Mode 1
• Adjustable Pre-Warning
• R1 output on during Pre-Warning, while in motion, and at an
undefined stopped position
• R2 output on at fully open and at open mid-stop
• R3 output on while closing only
90-T2 • 3 relay outputs (R1, R2, and R3)TCP Mode 2
• Adjustable Pre-Warning
• R1 output on during Pre-Warning only
• R2 output on at fully open
• R3 output on only when a special input to open has been used to
open the door which does not activate the Timer-to-Close
TCP Mode 3 90-T4 • 3 relay outputs (R1, R2, and R3)
• Adjustable Pre-Warning
• R1 output on during Pre-Warning only
• R2 output on at fully open and at open mid-stop
• R3 output on while in motion
90-RGLFCIR or 90-HDFLASH2 • TCP Mode 4 2 relay outputs (R1, R2) with optional flashing for R1
• Adjustable Pre-Warning
• R1 output on during Pre-Warning and while closing
• R2 output on at fully open
90-T3 • 3 relay outputs (R1, R2, and R3)TCP Mode 5
• Adjustable Pre-Warning
• R1 output on at all times except fully open and fully closed
• R2 output on at fully open
• R3 output on only when a special input to open has been used to
open the door which does not activate the Timer-to-Close
90-L3FLASH • 3 relay outputs (R1, R2, and R3) with optional flashing for R1TC Mode 1
• R1 output on while in motion
• R2 output on at fully open and at open mid-stop
• R3 output on at fully open, open mid-stop, and at an undefined
stopped position
90-42104 This mode allows a second set of external, track mounted limits to act SP Mode 1
as primary or backup for the operator’s open, close, and safety limits.
NOTE: It is not required that all three inputs have a switch connected to
the TLS1CARD. Either the external close, external safety, external open,
or all three may be used.
Produktspecifikationer
| Varumärke: | Liftmaster |
| Kategori: | Inte kategoriserad |
| Modell: | TLS1CARD |
Behöver du hjälp?
Om du behöver hjälp med Liftmaster TLS1CARD ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Liftmaster Manualer
25 September 2024
24 September 2024
24 September 2024
23 September 2024
23 September 2024
23 September 2024
23 September 2024
23 September 2024
23 September 2024
17 September 2024
Inte kategoriserad Manualer
- Infinity
- Morphy Richards
- Liemke
- GRE
- Topmove
- MXR
- ACOPower
- Core SWX
- Inglesina
- Ansmann
- Teltonika
- BluGuitar
- TikkTokk
- Dragonshock
- T.akustik
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025