Moxa TCF-142-M-SC Bruksanvisning
                    Moxa
                    
                    Inte kategoriserad
                    
                    TCF-142-M-SC
                
                                
    Läs gratis den bruksanvisning för Moxa TCF-142-M-SC (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 19 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 10 recensioner. Har du en fråga om Moxa TCF-142-M-SC eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
  — 1 —  — 2 —  — 3 — 
232-SR
232-SR584-SR224-SR
241-FCT
241-FCT241-FCT
xT
xT xTxT
xR
xRxRxR
241-FCT
0125
S-241-FCT
ws
xTxR
RWP
xTrebiF
xR rebi F
retre vnoC  rebiF ot laireS
584/224/232-SR
T+
T-R+/D+
R-/D-Tx
RxGND
584 /22 4-SR 232-SR V84-21
V+V-
0125
S-241-FCT
ws
xTxR
RWP
xTre biF
xR rebiF
retrevnoC reb iF ot laireS
584/224/23 2-SR
T+T-
R+/D+R-/ D-
TxRx
GND
584/224 -SR 232-S R V8 4-21
V+V-
0125
S-241-FCT
ws
xTxR
RWP
xTrebiF
xR rebiF
retrevnoC rebiF ot laireS
584/224/232-SR
T+T-R+/D+
R-/D-Tx
RxGND
584/224-SR 23 2-SR V84-21
V+V-
0125
S-241-FCT
ws
xTxR
RWP
xTrebi F
xR rebi F
retrevno C rebiF ot laireS 58 4/224/23 2-SR
T+T-
R+/D+
R-/D-Tx
Rx
GND
584/224-SR 232 -SR V84-21
V+V-
TCF-142 Series 
Serial to Fiber-optic Converter 
Quick Installation Guide 
Ninth Edition, April 2008 
1. Overview 
Introduction 
TCF-142 series (Rev. 3.1 or later) converters are equipped with a multiple 
interface circuit that can handle RS-232, RS-422, and RS-485 serial 
interfaces, as well as multi-mode or single-mode fiber. TCF-142 
converters are used to extend serial transmission distance up to 5 km 
(TCF-142-M, with multi-mode fiber) or up to 40 km (TCF-142-S, with 
single-mode fiber). The TCF-142 must be configured to transmit a 
particular serial interface. You cannot transmit both RS-232 and RS-485 
signals at the same time. 
Why Convert Serial to Fiber? 
Fiber communication not only extends the communication distance, but 
also provides many advantageous features. 
IMMUNITY FROM ELECTRICAL INTERFERENCE: Fiber is not 
affected by electromagnetic interference or radio frequency interference. 
It provides a clean communication path and is immune to cross-talk. 
INSULATION: Optical fiber is an insulator; the glass fiber eliminates the 
need for using electric currents as the communication medium. 
SECURITY: Fiber cannot be tapped by conventional electric means and 
is very difficult to tap into optically.   
RELIABILITY & MAINTENANCE: Fiber is immune to adverse 
temperature and moisture conditions, does not corrode or lose its signal, 
and is not affected by short circuits, power surges, or static electricity. 
Reverse Power Protection 
The Reverse Power Protection feature provides extra protection against 
accidentally connecting the power cables to the wrong terminal. The 
converter automatically detects which power wire is positive and which is 
negative. 
Ring Mode 
To allow one half-duplex serial device to communicate with multiple 
half-duplex devices connected to a fiber ring, you should configure the 
TCF-142 for “ring mode” by setting DIP switch “SW4” to the “On” 
position. The Tx port of a particular TCF-142 unit connects to the 
neighboring converter’s Rx port on the ring. Note that when one   
node transmits a signal, the signal 
travels around the ring until it 
returns back to the transmitting unit, 
which then blocks the signal. Users 
should ensure that the total fiber 
ring length is less than 100 km 
when using either single-mode 
models (TCF-142-S) or multi-mode 
models (TCF-142-M). 
ATTENTION 
For Fiber Ring Users: 
To avoid problems when setting up a fiber ring, each TCF-142 unit 
making up the ring must be powered down and set to “Ring mode.” Next, 
make sure all cables are connected properly, and then power up all 
devices connected to the ring. After powering up the TCF-142 units, if 
the Rx LEDs of the converters are ON continuously, power down and 
then power up ONE of the TCF-142 units in the ring to return the 
network to normal operation. 
NOTE  “Ring Mode” can only be used with half-duplex applications 
(i.e., RS-485 multi-drop communication). 
DIP Switch Selectable Terminator 
The TCF-142’s termination resistor is set with a DIP switch located on 
the outside of the converter’s casing. 
No Configuration Required for Baudrate Settings 
The TCF-142 is compatible with any baudrate from 300 bps to 921.6 
Kbps. The TCF-142 automatically converts the signal back and forth 
between serial (RS-232, RS-422, or RS-485) and fiber, and does not need 
to interpret the signal or the baudrate of the transmitting device. For this 
reason, the TCF-142 does not have any DIP switches or jumpers for 
setting the baudrate. 
2. Features 
y “Ring” or “Point to Point” transmission 
y Extend RS-232/422/485 transmission distance: 
> up to 40 km with single-mode—TCF-142-S Series 
> up to 5 km with multi-mode—TCF-142-M Series 
y Compact size 
y Decrease signal interference 
y Protect against electronic degradation and chemical corrosion 
y Supports baudrates up to 921.6 Kbps 
y Extended operating temperature from -40 to 75°C (for “T” models) 
3. Package Checklist 
Before installing the TCF-142, verify that the package contains the 
following items: 
y TCF-142 Fiber Converter 
y Quick Installation Guide 
y 7-contact terminal block connector 
y 3-contact terminal block connector 
NOTE: Please notify your sales representative if any of the above items 
are missing or damaged. 
4. Dimensions and Appearance 
TCF-142 fiber converters are easy to set up and use. The serial terminal 
block of one of the converters connects to your computer, the serial 
terminal block of the other converter connects to your serial device, and 
the two converters are connected by fiber cable(s). 
NOTE 
Electrostatic Discharge Warning! 
To protect the product from damage due to electrostatic 
discharge, we recommend wearing a grounding device when 
handling your TCF-142. 
TCF-142-M/S-ST  TCF-142-M/S-SC 
)ni 59.3( mm 4.001
22.0 mm
(0.87 in)
21.3 mm
(0.8 in)
42.3 mm (1.67 in) 67 mm (2.64 in)
78 mm (3.07 in)
12.5 mm
(0. 49 in)
)ni 89.0( mm 52
O 6 mm
(0. 24 in)
O 4 mm
(0. 16 in)
O 7 mm
(0. 28 in)
ON
1 2 3 4
67 mm (2.64 in)
78 mm (3.07 in)
12.5 mm
(0. 49 in)
)ni 89.0( mm 52
O 6 mm
(0. 24 in)
O 4 mm
(0. 16 in)
O 7 mm
(0. 28 in)
90.2 mm
(3.55 in)
67 mm
(2.64 in)
22.0 mm
(0.87 in)
ON
1 2 3 4
5. Wiring Examples 
Connecting the Power Supply 
Before using the TCF-142, first connect the DC power supply to the 
power supply terminal block located on the TCF-142’s bottom panel. 
DC
Power
Supply
RS-422/485
Rx
Tx
V  - V  -
V+ V+
GND GND
TCF-142
P/N: 1802001420618
Produktspecifikationer
| Varumärke: | Moxa | 
| Kategori: | Inte kategoriserad | 
| Modell: | TCF-142-M-SC | 
Behöver du hjälp?
Om du behöver hjälp med Moxa TCF-142-M-SC ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Moxa Manualer
                        
                         1 April 2025
                        
                    
                                                            
                        
                         27 Oktober 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            
                        
                         11 September 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Junkers
 - Bebe Confort
 - Candy
 - ALM
 - MADE
 - Epcom
 - CaterCool
 - Akuvox
 - Best Fitness
 - Weber
 - Canicom
 - I-Tec
 - FXLab
 - Firefield
 - Uniprodo
 
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025