Läs gratis den bruksanvisning för Kichler Kimrose 52410PN (3 sidor) i kategorin Lampa. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 3 recensioner. Har du en fråga om Kichler Kimrose 52410PN eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/3

REV 28-DEC-2020IS-52410-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1)Pass xture wires from coupling[L] on frame through tube[N]. Screw tube
onto coupling on frame.
2)Pass xture wires through short threaded tube[B] and screw short threaded
tube into top of tube[N].
3)Lower mast[P] down onto tube[N], making sure xture wires and short
threaded tube[B] pass through hole on top of mast.
4)Pass xture wires through coupling[Q] and screw coupling onto short
threaded tube protruding through the top of the mast.
5)Pass xture wires from coupling[Q] through desired number of stems[A] and
short threaded tubes[B]. Screw stems together using short threaded tubes.
NOTE: Thread locking compound must be applied to all stem threads as
noted with (4) symbol to prevent accidental rotaon of xture during
cleaning, relamping, etc.
6)Screw connected stems into coupling.
Fixture Diagram
Parts List
[A]Stems
[B]Short Threaded
Tubes
[C]Swivel
[D]Canopy
[E]Glass
[F]Socket Cover
[G]Mounting Strap
[H]Mounting Screws
[I]Outlet Box
[J]Knobs
[K]Lockwashers
[L]Coupling
[M]Strap Mounting
Screws
[N]Tube
[O]Plastic Tube
[P]Mast
[Q]Coupling
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
CLEANING:
•Always be certain that electric current is turned o before cleaning.
•Only a so damp cloth should be used. Harsh cleaning products may damage
the nish.
Installaon Instrucons (connued)
Installaon Instrucons
7)Pass xture wires from last stem through swivel[C]. Swivel should be
installed with the longer end hanging down towards the mounng stems.
8)Screw longer end of swivel into end of last stem.
Note direcon of swivel in accordance with ceiling.
NOTE: Fixture wires should not be cut shorter than 6” from top edge of
canopy.
9)Find the appropriate threaded holes on mounng strap[G] that align with
hole distance in canopy[D]. Assemble mounng screws[H] into threaded
holes.
10)Aach mounng strap to outlet box[I] using the strap mounng screws[M].
Mounng strap can be adjusted to suit posion of xture.
11)Grounding instrucons: (See Illus. a or b).
a)On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b)On xtures where a cupped washer is provided, aach ground wire from
outlet box under cupped washer and green ground screw, then thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector aer following the above steps. Never
connect ground wire to black or white power supply wires.
12)Make wire connecon. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
BlackWhite
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
13)Push xture to ceiling, carefully passing mounng screws through holes in
canopy.
NOTE: Be certain wires do not get pinched between mounng strap and
canopy, or canopy and ceiling.
14)Use knobs[J] and lockwashers[K] to secure canopy. Tighten to secure.
15)Carefully lower glass[E] down over socket onto base cup.
16)Carefully lower socket cover[F] down over socket.
17)Carefully lower plasc tube[O] onto socket cover and gently apply pressure
to push cover down completely over socket onto inside of glass.
18)Remove plasc tube from socket cover.
19)Repeat for remaining sockets.
20)Insert recommended bulbs (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLETBOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLETBOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
For warranty informaon please visit: kichler.com/warranty
►
►
►
►
►
P
B
L
E
F
O
A
D
G
H
M
►
C
K
J
I
B
A
Q
N
Produktspecifikationer
| Varumärke: | Kichler |
| Kategori: | Lampa |
| Modell: | Kimrose 52410PN |
Behöver du hjälp?
Om du behöver hjälp med Kichler Kimrose 52410PN ställ en fråga nedan och andra användare kommer att svara dig
Lampa Kichler Manualer
4 Februari 2026
4 Februari 2026
4 Februari 2026
2 Februari 2026
31 Januari 2026
30 Januari 2026
27 Januari 2026
24 Januari 2026
24 Januari 2026
8 Oktober 2025
Lampa Manualer
Nyaste Lampa Manualer
4 Februari 2026
4 Februari 2026
4 Februari 2026
4 Februari 2026
4 Februari 2026
3 Februari 2026
3 Februari 2026
3 Februari 2026
2 Februari 2026
2 Februari 2026