NetworX NX-6V2 System Keypad Bruksanvisning
Läs gratis den bruksanvisning för NetworX NX-6V2 System Keypad (20 sidor) i kategorin Säkerhet. Guiden har ansetts hjälpsam av 10 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 5.5 recensioner. Har du en fråga om NetworX NX-6V2 System Keypad eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/20

NetworX NX-6V2
LED Keypad User Manual

POWER Light is “on” w hen AC
power is present; flashes to
indicate a low battery
condition.
READY Light is “on” w hen the
system is ready to arm;
flashes if ready to “force arm”.
SERVICE Light is “on” to
indicate a trouble condition
with your system.
NX-6V2 SYSTEM
KEYPAD
Includes models
NX-108E, NX-116E, NX-124E
ARMED Light is “on” w hen
armed; “off” w hen disarmed;
flashes to indicate a previous
alarm.
INSTANT Light is “on” w hen
there is no entry/exit delay.
FIRE Light is “on” to indicate fire
alarm; flashes to indicate a
trouble condition with your fire
system.
ZONE LIGHTS are “on” steady
to indicate bypass; slow flash
for zone fault; rapid flash for
service condition.
PULL OUT ZONE ID TAB
NOTE: Some of the features described above may or may not be available for your system. Check with your installation company
to find out how your system is programmed.
5 FUNCTION KEYS perform
various functions.
EMERGENCY ACTIVATION KEYS
NUMERIC CODE
ENTRY KEYS

1
SECURITY SYSTEM NOTES
Installing/Service Company _________________________________
For Service Call __________________________________________
Central Station ___________________________________________
Duress Code ____________________
FUNCTION CODES
Function Code
Controls Function
This system is is not partitioned.
EMERGENCY ACTIVATION KEYS (check if enabled)
Fire
Auxiliary Emergency
Police
PROGRAMMED FUNCTIONS
Abort Delay ()
Cancel Alarm
Forced Arming ()
Auto Bypass ()
Change Partitions
Group Bypass ()
Auto Instant
Chime
Quick Arm ()
Battery Test
Communicator Test
Re Exit
Siren Test
() These features should not be enabled on UL listed systems.
ENTRY / EXIT DELAY TIMES
Exit Delay Time __________
Secondary Exit Delay Time ________
Entry Delay Time _________
Secondary Entry Delay Time _______
ZONE DESCRIPTIONS
01 _______________________
09 _______________________
02 _______________________
10 _______________________
03 _______________________
11 _______________________
04 _______________________
12 _______________________
05 _______________________
13 _______________________
06 _______________________
14 _______________________
07 _______________________
15 _______________________
08 _______________________
16 _______________________
Produktspecifikationer
Varumärke: | NetworX |
Kategori: | Säkerhet |
Modell: | NX-6V2 System Keypad |
Behöver du hjälp?
Om du behöver hjälp med NetworX NX-6V2 System Keypad ställ en fråga nedan och andra användare kommer att svara dig
Säkerhet NetworX Manualer
5 Oktober 2024
20 September 2024
10 September 2024
8 September 2024
8 September 2024
28 Augusti 2024
26 Augusti 2024
26 Augusti 2024
25 Augusti 2024
24 Augusti 2024
Säkerhet Manualer
- AVTech - Velleman
- Indexa
- Provision ISR
- Kocom
- Waeco
- PIR Alarm
- Smanos
- BRK
- Securitas
- Sygonix
- Switel
- Muller
- GE Security
- Grothe
- Monacor
Nyaste Säkerhet Manualer
19 Februari 2025
12 Januari 2025
7 Januari 2025
7 Januari 2025
24 Oktober 2024
22 Oktober 2024
21 Oktober 2024
20 Oktober 2024
20 Oktober 2024
Axis Camera Station S9001 Mk II Desktop Terminal Bruksanvisning
19 Oktober 2024