1.Product Overview
-2-
4.Key panel
-3--4-
Operation
Manual
Free Chlorine tester
PCE
-CHT 10
1.
2.
3
4.
5.
6.
7.
8.
9.
10.
11.
2
2
3
3
4
5
5
6
7
7
8
Product Overview
Precautions
CONFIGURATION and LCD INTRODUCTION
Key Panel
Battery and electrode installation
Measurement Mode
Calibration Mode
Set up
Parameters
Package
GENERAL INFORMATION
····························································
····································································
······················
········································································
··································
·······················································
····························································
··············································································
····································································
··········································································
···················································
TABLE OF CONTENTS
3.CONFIGURATION and LCD INTRODUCTION
Set up
Data stabilized
Calibration Mode
Low battery indicator
Measurement mode
Auto Lock function
Auto Lock after data stabilized
In calibration
Sensor slope is between 50%-200%
Sensor slope is between 33.3%-50% or 200%-300%
5.Battery and Electrode installation
Unscrew the screw cap by following the
arrow direction, slightly unplug the
electrode, install the battery(pay attention
to the anode and cathode of the
electrode).
Then install back the electrode and the
screw cap.
Low battery prompt is at the top of the
screen when battery power is low.( You can
refer to the LCD INTRODUCTION). Please
change the same model battery.
ENT
SET
CAL
PH30
ENT
SET
CAL
PH30
AAA
+
2.Precautions
Floats on water
IP67 rated
Large LCD with
backlight
Multi-line display
for easy reading
Field throw
measurement
( Auto Lock Function)
1*1.5V AAA
long battery life
PH0
EN
S
CAL
PH30
ENT
SET
CAL
E
SE
CAL
+
-
AAA
Calibration key when in measurement mode
Long press to enter into parameter browsing
Increment values or scroll through the next options available
Long press to Power ON/OFF
Short press to ON/OFF backlight
Escape key when in calibration mode and setting up
Data setting
Decrement values or scroll through the next options available
Confirm key
Press to unlock in Auto lock mode
Short press: Short press means release the key once after pressing.
(If there is no mark out below, default it as Short press)
Long press: Long press means press the key for 3 seconds and then release it
Hold: Hold means not release the key and accelerate after a certain time. Not release the key
until the value is set as needed.
Key instruction
Precise and easy operation, Comfortable holding, all functions operated in one hand.
Large LCD with backlight, Multi-line display for easy reading, Auto-Power Off saves battery after
5 mins non-use
1*1.5V AAA long battery life, User replaceable battery and high-impedance plane electrode.
Floats on water, IP67 rated
Field throw measurement( Auto Lock Function)
Use tri-electroded method measuring: faster and accurate, matching up to DPD results.
2 points calibrate
●
●
●
●
●
●
●
EN
CAL
ENT
SET
CAL
PH30
ENT
SET
CAL
CAL
Please wipe up the electorde with clean tissue or cloth before using.
Do not throw or beat ,squash or twist the tester deliberately.
Do not expose to the direct sunlight or put in high humidity or high
temperature environment .
Do not use for long time under water.
EN
SET
CAL
1.Align the bayonet according
to the corresponding position
1
1
2
2
2.After aligning the bayonet,
gently push it along the axis
3. Screw the fixing cap tightly
Pay attention to the corresponding
bayonet position
+
Axis
Produktspecifikationer
| Varumärke: | PCE Instruments |
| Kategori: | Mätutrustning |
| Modell: | PCE-CHT 10 |
Behöver du hjälp?
Om du behöver hjälp med PCE Instruments PCE-CHT 10 ställ en fråga nedan och andra användare kommer att svara dig
Mätutrustning PCE Instruments Manualer
PCE Instruments PCE-IT 120 Bruksanvisning PCE Instruments PCE-PH 15 Bruksanvisning PCE Instruments PCE-CPC 50 Bruksanvisning PCE Instruments PCE-DDA 10 Bruksanvisning PCE Instruments PCE-GA 10 Bruksanvisning PCE Instruments PCE-PA 7500 Bruksanvisning PCE Instruments PCE-PA 8500 Bruksanvisning PCE Instruments PCE-010-LED Bruksanvisning
Alla PCE Instruments Mätutrustning manualer
Populära i Mätutrustning
PCE Instruments PCE-DRG 5 Bruksanvisning PCE Instruments PCE-DRD 1 Bruksanvisning PCE Instruments PCE-TDS 100HS Bruksanvisning
Mätutrustning Manualer
Nyaste Mätutrustning Manualer
Kern KFP 60V30LM Bruksanvisning Kern ORA 4AB Bruksanvisning Grundfos Hydro Multi-S Bruksanvisning Sauter FH 500 Bruksanvisning Sauter FH 100 Bruksanvisning Sauter TVS 20KN100 Bruksanvisning Sauter CJ P4PG Bruksanvisning Sauter DA 5-3 Bruksanvisning Sauter SD 50N100 Bruksanvisning Sauter LB 200-2 Bruksanvisning