Läs gratis den bruksanvisning för PCE Instruments PCE-CPC 100 (15 sidor) i kategorin mätning. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 2 recensioner. Har du en fråga om PCE Instruments PCE-CPC 100 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/15

PCE- CPC 100
Dust Meter

2
2
2
22 27
27
27
2727/
PCE-CPC 100 Particle Counter
Description
The PCE-CPC 100 online particle counter adopts the principle of optical scattering, which can accurately detect and
calculate the number of suspended particles of different particle sizes in the air per unit volume. It can output the
particle count of 5 channels of 0.3μm, 0.5μm, 1.0μm, 5.0μm and 10μm at the same time (default unit is pcs/28.3L,
available to switch unit to be pcs/m³).
Features
⚫ l- Rea time output particle quantities of 0.3μm, 0.5μm, 1.0μm, 5.0μm, 10μm in pcs/28.3L or pcs/m³.
⚫ Sound and light alarm once particle quantity exceeds the set threshold.
⚫ ModBus communication protocols available.
⚫ - - Real time display cleanroom ISO 14644 1 grade level.
⚫ Output units switchable between pcs/28.3L and pcs/m³.
⚫ Constant flow gas sampling system to ensure stable sampling.
⚫ Industrial grade laser for high reliability.
Working Principle
Air sampling is carried out by a fan. When the particles in the sampled gas pass through a light source (laser) and
other beams, light scattering occurs; the scattered light is converted into an electrical signal (pulse) through a
photoelectric converter, and the larger the particle, the pulse signal is obtained. The larger the wave value (wave
peak value), the number of particles with different particle sizes can be obtained through the wave peak value and
the number of pulses at this time.
According to the block diagram , the light source part o consists of a laser tube that emits light to me f PCE-CPC 100
detect particles and a drive circuit, the detection part consists of a photosensitive element that receives reflected
light and an amplifier circuit, and the data processing and communication output are completed by a
microprocessor.
The particle detection of PCE CPC 100 is the gas flow generated by the operation of the fan, and the particles pass -
through the detection chamber. The light from the laser tube will be scattered by the particles and converted into
electrical signals by the photosensitive device. After the electrical signal is processed by amplifying circuit, filtering
and MCU, it will be converted into digital signal output.

3
3
3
33 27
27
27
2727/
Principle Light Scattering
Number of channels 5 channels (>0.3μ μ μ μ μ )m, >0.5 m, >1.0 m, >5.0 m, >10 m
Counting efficiency
50%@0.3μm
100%@≥0.5μm (25±2℃, 50±10%RH environmental conditions)
Detection range 0~1,000,000 pcs / 28.3L
Time to first reliable reading
≤8s
Sampling interval 1s
Working conditions
0℃~45℃; 0~95%RH (non-condensing)
Storage conditions
- - 20~60℃, 0~95%RH (non condensing)
Operating voltage DC 24V±15%
Average working current
≤3A
Communication Interface
RS485 interface (standard)
RJ45 (standard)
Lifetime
≥3 years (continuous working)
Sampling flow 28.3L/min
S ampling head Isokinetic Sampling Probe
External sampling tube
Inner diameter: ф10mm
Length: ≤3m
Working mode Adjustable (Default: Work 2min/Sleep 28min)
Display 3.5 inch color screen
Calibration JJF1190 -2008
1 x dust meter - PCE CPC 100
1 x isokinetic probe
1 x hose approx . 3 m
1 x mains cable
1 x mains adaptor 24 V / 5 A
1 x user manual
Specification
Packing Information
Produktspecifikationer
Varumärke: | PCE Instruments |
Kategori: | mätning |
Modell: | PCE-CPC 100 |
Behöver du hjälp?
Om du behöver hjälp med PCE Instruments PCE-CPC 100 ställ en fråga nedan och andra användare kommer att svara dig
mätning PCE Instruments Manualer
19 Juni 2025
19 Juni 2025
18 Juni 2025
mätning Manualer
Nyaste mätning Manualer
18 Juni 2025
18 Juni 2025
18 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025